VX4-UCMA-A2D2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 x SV Input, 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-UCMA-A2D2
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
2 x SV Inputs (Setpoint)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Â
TA800E-LG24, Green LED Bead Replacements for 24AC/DC TRIB, TRI Series Indicators
LED Will activate while the contacts are connected. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user.
Features :
240VAC or 24AC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TA800E-LG24
Functions
LED Indicator Bulb Replacement
Nominal Voltage
24AC/DC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Green LED
Approvals
CE
Weight
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Crydom DRA-CN024D24, Slimline Relay & Socket, 15-30VDC Coil, 3.5 Amp 24VDC Load
Features
Output 3.5 Amp @ 24VDC
15-30VDC Control input
DIN Rail Mount
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
DRA-CN024D24
Switching Type
24VDC 3.5 Amp SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
3.5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
24VDC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Crydom CN024D24, Slimline Relay, 15-30VDC Coil, 24VDC 3.5 Amp Load
Features
Output 3.5Amp @ 24VDC
15-30VDC Control input
DIN Rail Mount
Changeover Contact
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
CN024D24
Switching Type
24VDC 3.5 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
3.5 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
24VDC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Crydom DRA-CN240A24, Slimline Relay & Socket, 15-30VDC Coil, 2 Amp 24-280VAC Load
Features
Output 2Amp @ 250VAC
15-30VDC Control input
DIN Rail Mount
Ultra slim package
CE Compliant to IEC 60664
IP67
Specification
Crydom Part Number
DRA-CN240A24
Switching Type
250VAC 2 Amp Load SSR
Approvals
UL, CE
ROHS
Yes (Details)
Control Voltage
15-30VDC
Load Current
2 Amp (rms)
Special Feature
LED Status Indicator
Mounting Style
Socket Mount (F41F-1Z-C2-5 12-14VAC/DC)
Load Voltage Range
250VAC Load
EMC Compliant
Level 3
Termination Style
PCB or Socket Mount
Unit Weight
6g
Factory Pack Qty
20
Â
Datasheet
Relay Datasheet
F41F-1Z-C2-5 12-14VAC/DC Socket
Fastron Electronics SCT-Y24-100A/100mA, 100A/100mA Measurement, Class 1 Split Core CT's, Easy Click HY2.0 Connector for CRJ-31 RJ45 Splitter
Features
Quick Release Split Core System
Cable Mount
100mAmp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Â
Specification
Fastron Part Number
SCT-Y24-100A/100mA
Technology
Split Core AC Current Transformer
Ratio
100/100mA
Aperture Size
ø 24 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
100Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
Crydom HS501DR + D2450-10 Single Phase Solid State Relay 3-32VDC Control Input, Random Crossing, LED Status Indicator, 24-280VAC Output, 10 Amps Panel or Din Rail Mount
Features
Ratings from 25A to 125 Amp @24-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + D2450-10
Switching Type
Random Crossing
ROHS/CE/UL
Yes
Control Voltage
3-32VDC
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
N/A
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Â
Datasheet
HS501DR
D2450-10
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
R5011415XXZT 0614, Rotating Diode for Generators, 3/8" UNF 2A THD Stud, Cathode Stud, with 114mm Tail
User for Rotating Generator or Motor Applicatons
150 Amp Rating
Datasheet
Datasheet
BR6-FNSP3, Temp Controller, 48x24mm, 10-24VDC, TH-540N or NTC Input, 12VDC SSR
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNMP3
Control Output 1 (Heat)
10-15VDC 30mA
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
10-24VDC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
TX4L-U-D-N-2-96-A-N-N-N-W-N, Temp Controller, 96x96mm, 100-240VAC, Mutirange Input, 4-20mA Output, 2 Alarms, 4 x SV Input, Retransmisison Output
Mutirange Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 70 mm depth panel space
EC Compliant
Specification
Fastron Part Number
TX4L-U-D-N-2-96-A-N-N-N-W-N
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
Multirange (refer to datasheet)Â TC/RTD, 0-50mA/0-50mV
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
4-20mA PV Retransmission, 4 x SV (Setpoint)
Mounting Style
96x96mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
TX4L Series Instruction Manual
Â