Tocos RV24YN20S-B103 + GSBKA03-60, Single Turn Potentiometer (Standard) Linear 10K Ohm Panel Mount, Includes Platic Knob and Panel Position Indicator
Features
Panel Mount
Brush Type
Single Turn 270°
10Kohm
Linear
Datasheet
Product Datasheet
VX9-UCMA-A2, Temp Controller, 96x96mm, 100-240VAC, 4-20mA Output, Relay Cooling 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX9-UCMA-A2
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
N/A
Option 2
N/A
Mounting Style
96Â x 96mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
BR6-FNCP4, Temp Controller, 48x24mm, 100-240VAC, TH-540N or NTC Input, 4-20mA Output
Â
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNCP4
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Crydom HS211 + 10PCV2450, Single Phase Proportional Phase Controller with Heatsink, 2-10VDC Input, 240V, 25 Amps
Features
Proportional Phase Control Input
Ratings from 25A to 90 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Panel Mount
Din Rail Mount
Spec
Part Number
HS211 + 10PCV2450
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
2-10V Proportional Input
Load Current
25 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:81mm x W:45mm x D:73.4mm
Unit Weight
296g
Factory Pack Qty
20
Â
Datasheet
HS211
10PCV Series
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
VX4-UMMA-A1, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Relay Output, Relay Cooling 1 Alarm
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-UMMA-A1
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
N/A
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Â
NX1-04, Temp Controller, 48x24mm, 100-240VAC, Multirange Input, Multirange Relay/SSR/4-20mA Heating Outputs, Setup for Relay Heating Output, 1 Alarm
Multirange Dual Output and Input, User Selectable
Multirange Output (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
NX1-04
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4), or 4-20mA, or SSR (12VDC, 30mA 600 Ohm)
Control Output 2 (Cool)
N/A
Input
Multirange (refer to datasheet)
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
NX Series Brochure
NX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Â
VX4-UCNA-A2T, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, Programmable 4-20mA/SSR/Relay Output, 4-20mA Retransmission Output, 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-UCNA-A2T
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
4-20mA Retransmission (PV/SV/MV)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Â
Crydom HS501DR + RPC2440, Single Phase Proportional Phase Controller with Heatsink, for 500K - 1M POT input, 90-280VAC, 10 Amps
Features
Potentiometer Proportional Phase Control Input
Ratings from 25A to 40 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS501DR + RPC2440
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
10M Ohm Potnentiometer Proportional Input
Load Current
10 Amp (rms) @ 40 Deg C
Surge Capability
597 Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Din Rail or Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Screw Terminals
Dimensions
L:79.9mm x W:45mm x D:40.3mm
Unit Weight
296g
Factory Pack Qty
20
Â
Datasheet
HS501DR
RPC2440
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
VX4-USMA-A2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, SSR Output, Relay Cooling 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-USMA-A2
Control Output 1 (Heat)
SSR 12-15VDC @30mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85Â - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Â
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Â
Crydom A2450EG, Solid State Relay, Single Phase 18-36VAC Control, 50A, 24-280VAC Load w/status LED
Features
• Ratings from 25A to 125 Amp @ 24-280 VAC
• SCR output for heavy industrial loads
• Zero voltage or instantaneous turn-on outputs
• UL/CSA/VDE Approved, CE Compliant to EN60950-1
• Improved SEMS screw and washer
• Redesigned housing with anti-rotation barriers
• AC & DC control types
• Direct bond copper substrate
• EMC compliant to Level 3
• Direct power lead frame
• Epoxy free design
Spec
Crydom Part Number
A2450EG
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
24VAC (18 - 36VAC)
Load Current
50 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
90 - 280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Â
Datasheet
Product Datasheet
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies