Crydom D2425DE, Dual Solid State Relay, Two Pole 15-32VDC Control, 2 x 25A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2425DE
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
15-32VDC
Load Current
2 x 25 Amp (rms)
Surge Capability
250 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra Doo TSD 1 UNI, Twilight Switch, Universal 12-240VAC/DC Power Supply, 16 Amp SPST CO Relay
TSD 1 Series serves to monitor luminance from 1 to 50,000lx, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Used to control lights on the basis of ambient light intensity
External sensor IP44 suitable for mounting on the wall (cover and holder of a sensor are a part of the package)
Red LED output indication
1-MODULE, DIN rail mounting Level of ambient intensity is monitored by an external sensor and output is switched according to set level on the device
Control input for additional control, e.g. time switch, preswitch etc.
Level of illumination adjustable in two ranges: 1 - 100 lx and 100 - 50000 lx Adjustable time delay to eliminate short term fluctuation in illumination
Supply voltage AC 230 V or AC/DC 12 - 240 V
Output contact: 1x changeover/ S
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Iskra Doo Part Number
TSD 1 UNI
Voltage Range
AC 12 - 240 VAC/DC
Operating Range
-15 %; +10 %
Current Range
0.05 - 5 A (AC 50 Hz)
Trip Adjustment
Potentiometer
Setting Accuracy
30 %
Burden
max. 12 VA
Repeatability
1 %
Temperature Drift
0.1%/°C
Peak Overload (10s)
100 Amp
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Luminance range
2 Ranges 1-100lx, 100-50,000lx
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
16 A / AC1
Breaking capacity
4000 VA / AC1, 384 W / DC
Inrush current (3s)
30 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
109 g
Standards
EN 60255-6, EN 61010-1
Datasheet
Product Datasheet
VX9-UCNA-A2D2, Temp Controller, 96x96mm, 100-240VAC, Multirange Input, 4-20mA Output, 2 Alarms, 2 x SV
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX9-UCNA-A2D2
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
2 x SV (2 Setpoints/Event Input)
Mounting Style
96x96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Dynex DCR960G18, Thyristor(SCR) PUK, 960Amp, 1800V, 58/26 Capsule
Features
Very low forward voltage drop
Very low leakage current
International standard package
58/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
Dynex Part Number
DCR960G18
Vrrm
1800V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ 60 Deg C
960 Amp
Package Size
ø58 x 26mm
Itsm
14 kA
VF(to)
0.91V
Tj(max)
125°C
rF
0.36mΩ
Gate Terminals
400mm Gate Leads with 6.3 x 0.8mm Spade Lugs
R th(j-c) (double sided cooled 180°sin)
0.035°C/W
R th(c-h) (double sided cooled)
0.008°C/W
Weight
600g
Clamping Force
12 - 18kN
Factory Pack Qty
12
Certification
ROHS
Dynex Headquarters
UK
Datasheet
Product Datasheet
Dynex 2022 Shorform Catalogue
Alternatives
N1114LC160
T718N16TOF
T720N16TOF
T880N18TOF
Heatsink
Heatsink Profiles
Allen Bradley YST14-01YAP6-01 P18C VS170 101-GF, Thyristor(SCR) PUK, 1130Amp, 1800V, 74/26
Features
Very low forward voltage drop
Very low leakage current
International standard package
74/26 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Field Supply for DC Motors
Water Cooled Rectifiers
DC Substation Blocking Diode
Large Generators
Specification
ABB Part Number
YST14-01YAP6-01 P18C VS170 101-GF
Vrrm
1800V
Diode Configuration
Thyristor Capsule (PUK)
IF(av) @ Tc = 115 Deg C
1130 Amp
Package Size
ø74 x 26mm
Clamping Force
22kN
Tj(max)
125°C
Gate Terminals
Faston
Weight
600g
Factory Pack Qty
6
Certification
ROHS
ABB Headquarters
Switzerland
Heatsink
Heatsink Profiles
Datasheet
Datasheet
BR6-FNMP3, Temp Controller, 48x24mm, 10-24VDC, TH-540N or NTC Input, Relay Output
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNMP3
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
10-24VDC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Crydom HD4875G, Solid State Relay, Single Phase 3-32VDC Control, 75A, 48-530VAC Load, w/status LED
Features
Ratings from 25A to 125 Amp @ 48-480VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HD4875G
Switching Type
Zero Crossing
ROHS
Yes (Details)
Control Voltage
4-32VDC
Load Current
75 Amp (rms)
Surge Capability
954 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See HD4875 for stocked equivalent (no LED).
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
BR6-FNMP4, Temp Controller, 48x24mm, 100-240VAC, TH-540N or NTC Input, Relay Output
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNMP4
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Crydom 84140900, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
84140900
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Mitsubishi CM600HA-24H, Single IGBT 600 Amp, 2400V, 80mm Base Width
Specification
Schurter Part Number
CM300HA-12H
Configuration
Single Insulated IGBT
Nominal Voltage
1200V
Collector Current (Ic)
600 Amp
Collector Current (Tj < 150 Deg C)
1200 Amp
Isolation
2500VAC
Dimensions
80 x 110 x 36mm
Mounting Style
Panel Mount
Operating Temperature Range (Tj Max)
-40°C / 150°C
Maximum Collector Dissipation
4100W
Unit Weight
560g
Factory Pack Qty
10
Datasheet
Product Datasheet
Eastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516
Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters.
Can be used for any 100 Amp Direct Connect application
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
SAA Approved
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM230Modbus-MID-V2 (SLX)
Functions
Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
230V L-N 230V L-N, 100 Amp
Maximum Measurement Range
276 L-N 230V L-N,100 Amp
Nominal Current Input
Direct connect 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (100ms Response)
Weight
250g
Certification
EN 61010-1 Installation Category III, SAA212516
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility