Search results for "24�üҾױ������� �Ų� banonpi �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
CMI4 7504, 75uF, 50x119mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC
Meco Capacitors CMI4 7504, 75uF, 50x119mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC Characteristics and utility 75uF 450VAC UL94 V2 Plastic Housing Metalized Polypropylene Film Connector type - Double Faston Terminals M8 Stud mounting Standards IEC 60252-1 Specification Meco Capacitors Part Number CMI4 7504 Technology Metalized Polypropylene Film Capacitor Dimensions ø50x119mm Mounting M8 Stud Standards IEC 60252-1 Voltage 450VAC Operating Temperature Range -25 to 85 °C Capacitance 75uF Tolerance On Capacitance +5 / -5% Lifetime10 10,000 Hours (Statistical Life) Termination Style Double Faston Terminals Mounting Style M8 Stud Unit Weight 0.07kg Factory Pack Quantity 5 (MOQ = 100pcs) Datasheet Product Datasheet
$40.00
$47.20 inclGST -
FRS 2500-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 2500-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
LV 25-200, C/L Voltage Transducer, 200V, 25mA Output
Free Aus Post Shipping for $300 SpendLEM LV Series Closed Loop AC/DC Hall Effect Voltage Sensor Features Bandwidth DC to 40kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number LV 25-200 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-12..15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) 200V Measurement Range 0 - 300V Output 25 mA @Vpn Isolation 4.1 kV Bandwidth DC-40 kHz Mounting Style PCB Mount Operating Temperature Range -40°C / 70°C Accuracy 0.8% Termination Style Fastron 6.3 x 0.8mm Unit Weight 60g Factory Pack Quantity 25 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
CMI4 1204, 12uF, 35x69mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC
Meco Capacitors CMI4 1204, 12uF, 35x69mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC Characteristics and utility 12uF 450VAC UL94 V2 Plastic Housing Metalized Polypropylene Film Connector type - Double Faston Terminals M8 Stud mounting Standards IEC 60252-1 Specification Meco Capacitors Part Number CMI4 1204 Technology Metalized Polypropylene Film Capacitor Dimensions ø35x69mm Mounting M8 Stud Standards IEC 60252-1 Voltage 450VAC Operating Temperature Range -25 to 85 °C Capacitance 12uF Tolerance On Capacitance +5 / -5% Lifetime10 10,000 Hours (Statistical Life) Termination Style Double Faston Terminals Mounting Style M8 Stud Unit Weight 0.07kg Factory Pack Quantity 5 (MOQ = 100pcs) Datasheet Product Datasheet
$21.25
$25.08 inclGST -
FRS 1000-SUIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 1000-SUIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
FRS 3000-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 3000-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
UMT540-HSHFNAAAM, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable analogue outputs, 1 Relay Alarm Output, USB, Ethernet, RS485 Comms
Iskra Doo UMT540-HSHFNAAAM, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable analogue outputs, 1 Relay Alarm Output, USB, Ethernet, RS485 Comms (U)MT version = Ring type terminal block Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number UMT540-HSHFNAAAM Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 3 x Analogue, 1 x Relay Alarm Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations Ring Type Terminal Block Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software
$1,836.00
$2,166.48 inclGST -
FRS 2000-SUIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 2000-SUIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2000-SU Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-6000 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
CMI4 3004, 30uF, 40x94mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC
Meco Capacitors CMI4 3004, 30uF, 40x94mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC Characteristics and utility 30uF 450VAC UL94 V2 Plastic Housing Metalized Polypropylene Film Connector type - Double Faston Terminals M8 Stud mounting Standards IEC 60252-1 Specification Meco Capacitors Part Number CMI4 3004 Technology Metalized Polypropylene Film Capacitor Dimensions ø40x94mm Mounting M8 Stud Standards IEC 60252-1 Voltage 450VAC Operating Temperature Range -25 to 85 °C Capacitance 30uF Tolerance On Capacitance +5 / -5% Lifetime10 10,000 Hours (Statistical Life) Termination Style Double Faston Terminals Mounting Style M8 Stud Unit Weight 0.07kg Factory Pack Quantity 5 (MOQ = 100pcs) Datasheet Product Datasheet
$21.25
$25.08 inclGST -
LV100-1000/SP16, C/L Voltage Transducer, 1000V, +/-15VDC Aux, 50mA Output, SP16 = -25 to 70 Deg C, Vp = +/-1700V
Free Aus Post Shipping for $300 SpendLEM LV100-1000/SP16, C/L Voltage Transducer, 1000V, +/-15VDC Aux, 50mA Output, SP16 = -25 to 70 Deg C, Vp = +/-1700V Features Bipolar and insulated voltage measurement up tp 1500VAC/DC Current output Closed loop (compensated) voltage transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LV 100-1000/SP16 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC Bipolar, Isolated Primary RMS Voltage 1000V Measurement Range +/- 1700 V Output 50 mA Isolation 6 kV Response 40uS Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet
-
KNL250-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 250 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL250-00-24VAC Contactor Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL250-00-24VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 250 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO Trip Delay Time 2-10ms Electrical Life 1,100,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 24.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
CMI4 6504, 65uF, 45x119mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC
Meco Capacitors CMI4 6504, 65uF, 45x119mm Motor Run Motor Start Capacitor w/ M8 Mounting Stud -25 to 85 °C 10,000 hrs, 450VAC Characteristics and utility 65uF 450VAC UL94 V2 Plastic Housing Metalized Polypropylene Film Connector type - Double Faston Terminals M8 Stud mounting Standards IEC 60252-1 Specification Meco Capacitors Part Number CMI4 6504 Technology Metalized Polypropylene Film Capacitor Dimensions ø45x119mm Mounting M8 Stud Standards IEC 60252-1 Voltage 450VAC Operating Temperature Range -25 to 85 °C Capacitance 65uF Tolerance On Capacitance +5 / -5% Lifetime10 10,000 Hours (Statistical Life) Termination Style Double Faston Terminals Mounting Style M8 Stud Unit Weight 0.07kg Factory Pack Quantity 5 (MOQ = 100pcs) Datasheet Product Datasheet
$36.25
$42.78 inclGST