Search results for "24�üҾױ������� �Ų� banonpi �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
L25J25RE, 25 Ohm, 25W Resistor Wire Wound
Free Aus Post Shipping for $300 Spend25 Ohm, 25W Resistor Wire Wound
-
RS1API420MA280025R, Single Phase Proportional Phase Controller, 4-20mA Input, 240V, 25 Amp
Free Aus Post Shipping for $300 SpendRelequick RS1API420MA280025R Proportional Phase Control Solid State Relays 4-20mA, or 2-10V Proportional Phase Control Input Ratings from 25A to 100 Amp @ 70-280 VAC SCR output for heavy industrial loads Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Relequick Part Number RS1API420MA280025R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4 - 20mA Load Current 25 Amp (rms) Surge Capability 350Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 70-280VAC Max Non Repetitive Peak Voltage 850 Vp Termination Style Screw Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet Product Notifications Equivalent Parts Relequick RS1API420MA280040R RS1API420MA280060R RS1API420MA280080R or Crydom MCPC2450 MCPC2490 or Contact Us for Possible Replacement
-
PFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux
Free Aus Post Shipping for $300 SpendPFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux Single 1/5A CT Sensing Automatic Step Sensing (After start up sequence) Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 240VAC Aux Supply Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Rishabh Part Number PFC 08-8-R-RTC Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 240VAC (L-N), 15VA 40-70Hz +/-10% Relay Rating 250VAC/10Amp Panel Size 96 x 96mm Switch Delay Time 10s - 1800s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 10 - 1800s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 9 Smallest Capacitor Current 10mA CT Input Range 1/5 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Panel Size 96x96mm Panel Mount Comms RS485 Termination Style Screw Weight 700g Certification IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water) Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to IEC 61010-1-2010, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Product Datasheet User Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
-
H25D-SS-12NB-S1-CW-ECS18, Optical Incremental Encoder Heavy Duty 25" Diameter, Shaft Seal, 12 Cycles/Turn
Heavy Item - No Free ShippingSensata (BEI Sensors) H25D-SS-12NB-S1-CW-ECS18, Optical Incremental Encoder Heavy Duty 25" Diameter, Shaft Seal, 12 Cycles/Turn The H25 is the flagship of the BEI Sensors product line. It was designed from the ground up for the industrial marketplace. The H25 offers features such as EMI shielding, 40 lb. ABEC 7 bearings, matched thermal coefficients on critical components, and custom high efficiency optics. The encoder meets NEMA 4 and 13 requirements when ordered with the shaft seal. Typical applications include machine control, process control, the wood processing industry, oil well logging, industrial weighing, agricultural machinery, textile equipment, web process control, robotics, and food processing. Special Models of the H25 Incremental Encoder are available with one or more of the following certifications. Consult factory for details. Specification Sensata (BEI Sensors) Part Number H25D-SS-12NB-S1-CW-ECS18 (01079-222) Housing Square Flange Shaft Seal Config Shaft Seal Cycle Per Turn 12 No. of Channels Dual with Index Complements Complimentary Outputs Encoder Type Incremental Optical Voltage Output Termination Location End Output Termination Pigtail 18" long Unit Weight Factory Pack Qty 1 Datasheet Product Datasheet Selection Guide Selection Guide
-
FRS 2500-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 2500-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
HCT-0024-200, Split Core DC Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 24mm Aperture, X = 1%
Free Aus Post Shipping for $300 SpendMagnelab HCT-0024-100, Split Core DC Hall Effect Current Sensor, 200 Amp, +/-4V Output, Split Core 24mm Aperture, X = 1% Features Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification Magnelab Part Number HCT-0024-200 Technology Split Core Open Loop Hall Effect Aperture ø24mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 200 Amp Measurement Range +/-300 Amp Output +/-4 V Isolation 4 kV Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style Flying Lead Unit Weight 400g Factory Pack Quantity 10 Datasheet Product Datasheet
-
GFIN/70M-DR + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount
Free Aus Post Shipping for $300 SpendGFIN/70M-DR + PMP2425W DIN Mount, Proportional Controller, 25 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 90-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number GFIN/70M-DR + PMP2425W Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 25 Amp (rms) Surge Capability 296 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 90-280VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 800g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide GFIN Product Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Parts Contact Us for Possible Replacement
-
GH1, HV Relay/Contactor with RF Screening, 3.5kVDC, 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz), SPDT-CO, 24DC Coil, 2,000,000 Cycles
Free Aus Post Shipping for $300 SpendGigavac GH1, HV Relay/Contactor with RF Screening, 3.5kVDC, 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz), SPST-NO, 24DC Coil, 2,000,000 Cycles Features RF efficient design offers high power handling in asmall package High voltage solder connections provide additionalexternal isolation from PC boards RF screen helps assure interference free operationwhen relays are mounted side by side Vacuum dielectric offers low stable contact resistance Small and lightweight Flexible package for installation Specification Gigavac Part Number GH1 Main Contact Type SPDT-CO Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 25Amp DC/50/60Hz or 14 Amp RMS(2.5MHz), 9 Amp RMS(16Mhz), 1.5 Amp RMS(32 Mhz) Mechanical Life @ 0 Amp 2,000,000 Operations Impulse Withstand 3.5kV rms Control Input Terminals Solder Tabs Special Feature N/A Mounting Style Panel Mount (M2) Load Voltage Range 3.5kVDC (up to 30Mhz) Standards Termination Style Solder Tabs Unit Weight 24g Factory Pack Qty 1 Datasheet Product Datasheet
-
FP25R12KE3, Trench IGBT and Emitter Controlled 3 Diode, 25 Amp, 1200V, Press Fit 45mm base width
Infineon FP25R12KE3, Trench IGBT and Emitter Controlled 3 Diode, 25 Amp, 1200V, Press Fit 45mm base width Features IGBT for Rectifier Pressure Contact Technology Electrically insulated base plate Press Mounted Style 2500V Isolation 61mm Base Width Applications Frequency Converter Line rectifying 50/60 Hz Deep Cycle Applications Controlled Rectifiers Inverter Drives Specification Infineon Part Number FP25R12KE3 Vces 1200V Transistor Configuration H Bridge IGBT Module & Emitter Controlled Diodes x 3 Ic(nom) @ 80 Deg C 150 Amp Package Size W:162mm L:150mm D:20mm V(isol) 2.5 kV Vf @ 25 Deg C 1.65 - 2.15V Tj(max) 150°C Td(on) @ 25 Deg C 0.25uS Td(off) @ 25 Deg C 0.55uS I(ces) @ 25 Deg C 5mA Rcc 1.1mOhm Terminals Press Fit Gate Terminals Pin Weight 180g Mounting Torque 5 Nm (4 Nm Terminals) Factory Pack Qty 10 Certification UL Listed, ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives No Alternative
$139.00
$164.02 inclGST -
D2410-B, SSR 3-32VDC Control input, 10A 90-280VAC, Normally Closed
Free Aus Post Shipping for $300 SpendCrydom D2410-B, SSR 3-32VDC Control input, 10A 90-280VAC, Normally Closed Features Ratings from 25A to 125 Amp @ 24-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number D2410-B Switching Type Zero Crossing, Normally Closed ROHS Yes (Details) Control Voltage 3-32VDC Load Current 25 Amp (rms) Surge Capability 239 Amp (peak) Special Feature Normally Closed Mounting Style Panel Mount Load Voltage Range 24-280VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
ATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply
Free Aus Post Shipping for $300 SpendATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Insant output versions 4-20mA, 0-20mA, 0-10V, 0-5V output Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 2.5kV Rms /50 Hz /1min Low power consumption Package in ABS Instantaneous voltage or current output options Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number ATO-CUS-DC20000-4000-420U Technology Open Loop Hall Effect ROHS Yes Supply Voltage +24VDC Load Current (RMS + DC) 4000 Amp Overload Rating N/A Output 4-20 mA Instantaneous Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Only Mounting Style Busbar or Panel Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet
-
FRS 2500-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
LEM FRS 2500-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SBI Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 5.3 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$475.00
$560.50 inclGST