Search results for "24�üҾױ������� �Ų� banonpi �ٳ��� �������ɳ����� �ɸ��Թ��� �۾��������ſ� �������� �ź��ڻ����ڱݴ�������"
-
CME5 21 uF250VAC1.7, Motor Start Capacitor, Plastic Case 21-25 uF250VAC 50/60Hz with Double Faston Terminals, Flat Base, D38x70mm, General Type 1.7% Duty
Meco Capacitors CME5 21 uF250VAC1.7, Motor Start Capacitor, Plastic Case 21-25 uF250VAC 50/60Hz ??with Double Faston Terminals, Flat Base, D38x70mm, General Type 1.7% Duty Characteristics and utility 21uF 250VAC UL94 V2 Plastic Housing Metalized Polypropylene Film Connector type - Double Faston Terminals Flat Base Standards IEC 60252-1 Specification Meco Capacitors Part Number CME5 21 uF250VAC1.7 Technology Metalized Polypropylene Film Capacitor Dimensions ??38x70mm Mounting M8 Stud Standards IEC 60252-1 Voltage 250VAC Operating Temperature Range -25 to 65 ??C Capacitance 21-25uF Tolerance On Capacitance ? / -10% Lifetime10 10,000 Hours ??(Statistical Life) Termination Style Double Faston Terminals Mounting Style M8 Stud Unit Weight 0.07kg Factory Pack Quantity 5 (MOQ = 100pcs) ?? Datasheet Product Datasheet
$35.00
$41.30 inclGST -
HAZ 20000-SBI, O/L Current Transducer, 20000 Amp, +/-15VDC supply, +/-20mA Output
Free Aus Post Shipping for $300 SpendLEM HAZ 20000-SBI, O/L Current Transducer, 20000 Amp, +/-15VDC supply, +/-20mA Output For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Instantaneous output version +/-10V, +/-20mA True RMS output versions 4-20mA, 0-10V putput Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 17kV Rms /50 Hz /1min Low power consumption Package in PBT meeting UL 94-V0 Instantaneous voltage output Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number HAZ 20000-SBI Technology Open Loop Hall Effect ROHS Yes Supply Voltage +/- 15VDC Load Current (RMS + DC) 20000 Amp Overload Rating 30000 At Output +/-20 mA Instantaneous Isolation 17kV (AC, 50Hz, 1 min) Bandwidth DC-3kHz Mounting Style Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet
-
FRS 1500-SUIH, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 1500-SUIH, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1500-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1500 Amp Measurement Range +/-4500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
MC330 H ARNG SUNNNAT, Panel Mount Mutifunction Meter with Harmonics (31st), Class 0.5s, 50-500VAC 50/60Hz Measurement, Universal 20..300VDC 48..276VAC Aux, Internal Logger
Free Aus Post Shipping for $300 SpendMC330 H ARNG SUNNNAT, Panel Mount Mutifunction Meter with Harmonics (31st), Class 0.5s, 50-500VAC 50/60Hz Measurement, Universal 20..300VDC 48..276VAC Aux, Internal Logger Internal 8MB Logger Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency Optional RS 232/RS 485 communication up to 115,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Internal Logger Measurement of instantaneous values of more than 60 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Includes Harmonics Accuracy class 0.5 Measurement of 20 minimal and maximal values in different time periods Optional dual tariff inputs and pulse or relay outputs Wide frequency range from 16 Hz to 400 Hz RS 232/RS 485 communication up to 115,200 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal or AC power supply Graphic LCD 128 x 64 dots with illumination Automatic range of nominal current up to 5 A and nominal voltage up to 600 V Multilingual support User-friendly PC MiQen software Specification Iskra Doo Part Number MC330 H ARNG SUNNNAT Functions Energy Meter Supply Voltage Universal 20..300VDC 48..276VAC Nominal Measurement Range 50-500V L-N (Autoranging), 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm 2 x Relay Outputs Tariff Input Optional 2 x Analogue Outputs Optional 2 x Programmable Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Internal Logger Yes (8MB) RS232/RS485 N/A Optional CT Terminations Through Hole CT Weight 500g Certification UL, CSA, ROHS Factory Pack Qty 1 EU Directives Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002 Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2) Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997 Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C Datasheet Product Datasheet User Manual
-
FRS 1000-SBIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 1000-SBIH, O/L Coreless Current Transducer, 1000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coresless Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1000-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1000 Amp Measurement Range +/-3000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
FRS 1500-SBIH, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 1500-SBIH, O/L Coreless Current Transducer, 1500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 1500-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 1500 Amp Measurement Range +/-4500 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 3000-SBIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 3000-SBIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 3000 Amp Measurement Range +/-9000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST -
MOD2 3NL 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Fixed Type Icu = 36kA, Ics = 27kA, 125 Amp, 400/690VAC
Free Aus Post Shipping for $300 SpendIskra Doo MOD2 3NL 125A, 3 Pole Moulded Case Circuit Breaker (MCCB) Thermal and Magnetic Release Fixed Type Icu = 36kA, Ics = 27kA, 125 Amp, 400/690VAC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 36kA Short Circuit Rating @400VAC Suitable for Main Incoming Breaker Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MOD2 3NL 125A Functions 3 Pole MCCB Nominal Voltage 400/690VAC @ 50/60Hz Nominal Current Range 125 Amps RMS Trip Delay Time < 50ms Rated Impulse Voltage 8kV Operating Temperature -25 to 50 Deg C Mechanical Operations 20,000 Ops Insulation Voltage 800V Short Circuit Current Icu = 36kA, Ics = 27kA, @ 400VAC, Icu =20kA @ 690VAC Approvals KEMA EUR, CE Standards IEC/EN 60898-1,IEC/EN 60947-3, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 1.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet
-
PPMF 200-12.5 C6 Snubber Capacitor ø75x110mm 2kVDC 12.5uF, Railway Grade
Free Aus Post Shipping for $300 SpendPPMF 200-12.5 C6 Snubber Capacitor ø75x110mm 2kVDC 12.5uF, Railway Grade Characteristics and utility Railway grade 2.5 kVDC, 800VAC rms, 12.5uF Resin end sealing Srew terminals Suitable for hazardous environments Flat Base Standards IEC 60831-1/2 EN 60831-1/2 Specification LeClanche Part Number PPMF 200-12.5 C6 Technology Dielectric of Metallized Polypropylene Dimensions 75 x 110mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage (DC) 2000VDC Voltage (AC) 800VAC rms Capacitance 12.5uF Tolerance On Capacitance +/- 10% Current Ieff (max) 35 Amp Current I cr (max) 1500 Amp ESR 4.5mΩ ESL <170nH Estimated Operational Life 100 x 10²6 Discharges Mounting Flat Base Climate Category 25/70/56 Termination Style M5 x 10mm (32mm thread spacing) Unit Weight 500g Factory Pack Quantity 25 Datasheet Product Datasheet
-
N2593MK160, Thyristor(SCR) PUK, 1769 Amp, 1600V, 74/14
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N2593MK160, Thyristor(SCR) PUK, 1769 Amp, 1600V, 74/14 Features Very low forward voltage drop Very low leakage current International standard package 101/34 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode Part Number N2593MK160 Vrrm 1600V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C 1684 Amp Package Size ø74 x 14mm Itsm 34.5 kA VF(to) 0.94V Tj(max) 125°C rF 0.154mΩ Gate Terminals Faston R th(j-k) (double sided cooled 180°sin) 0.014°C/W R th(c-h) (double sided cooled) Weight 0.27kg Clamping Force 25 - 31kN Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement Heatsink Heatsink Profiles
-
HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps
Free Aus Post Shipping for $300 SpendCrydom HS211 + MCBC2425CF, Single Phase Proportional Burst Controller with Heatsink, 10 Cycles, 0-10VDC Input, 90-280VAC, 24 Amps Features Proportional Phase Control Input Ratings from 25A to 90 Amp @ 180-280 VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Panel Mount Din Rail Mount Spec Part Number HS211 + MCBC2425CF Switching Type Burst Fire (Zero Crossing) ROHS/CE/UL Yes Control Voltage 0-10V Proportional Input Load Current 24 Amp (rms) @ 40 Deg C Surge Capability 239 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Din Rail or Panel Mount Load Voltage Range 180-280VAC Max Non Repetitive Peak Voltage 600 Vp Termination Style Screw Terminals Dimensions L:81mm x W:45mm x D:73.4mm Unit Weight 296g Factory Pack Qty 20 Datasheet HS211 MCBC Series Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
FRS 2000-SBIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version
LEM FRS 2000-SBIH, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2000-SU Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2000 Amp Measurement Range +/-6000 Amp Overload Rating N/A Output 4-20mA Bipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$995.00
$1,174.10 inclGST