Recommended products

4104 products

  • LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display

    LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display

    22 pcs in stock

    Risbabh LM1360-MA4L-4-3-01-02-R-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 Comms, Three Section LCD Display 2 Pulse Outputs Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N Three Section Display RS 485 communication up to 19,200 bit/s RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor THD up to 31sth Harmonic 85 Parameter Measurement The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.2 Simple Menu RS 485 communication up to 19,200 bit/s MODBUS communication protocol 240V AC power supply Specification Rishabh Part Number LM1360-MA4L-4-3-01-02-R-H-2 Functions kWh Meter, Energy Meter Supply Voltage 240VAC < 5VA Nominal Measurement Range 600V L-L 350V L-N, 5 Amp Maximum Measurement Range 600V L-L 350V L-N, 6 Amp Display Three Line LCD Pulse Output 2 (input or output) Accuracy Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Ethernet Modbus RTU Over TCP/IP 2400-19200 b/s Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.

    22 pcs in stock

    $309.00
    $364.62 inclGST

  • Last stock! EQ96/100/5A, Moving Iron Ammeter, 100/5A, 96 × 96mm, Class 1.5-Moving Coil Meter-Rishabh Instruments-Fastron Electronics Store DE96/100/5A, Moving Iron Ammeter, 100/5A, 96 × 96mm, Class 1.5

    DE96/100/5A, Moving Iron Ammeter, 100/5A, 96 × 96mm, Class 1.5

    3 pcs in stock

    Rishabh DE96/100/5A, Moving Iron Ammeter, 100/5A, 96 × 96mm, Class 1.5 Features Adjustable Display Scaling PC 94 UL V0 For robust Measurement Each unit needs just 96 x 96mm Panel Space 65mm Depth Specification Rishabh Part Number DE96/100/5A Nominal Measurement Range 0 - 100 Amp AC Maximum Measurement Range 100 Amp Over Range Isn x 2 Operating Temperature 0 - 50°C Frequency 15...100Hz Safety Rating IP52 case, IP20 terminals wiht back cover Termination Style Screw Mounting Style 96 x 96mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1   Datasheet Product Datasheet

    3 pcs in stock

    $47.50
    $56.05 inclGST

  • FC5-M-W-1-G-2-C, PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and  PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output

    FC5-M-W-1-G-2-C, PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output

    27 pcs in stock

    Fastron FC5-M-W-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and  PT100/Cu20 RTD Input, 72x72mm, Relay + SSR Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-M-W-1-G-2-C Control Output SSR/Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ SSR 12VDC @20mA Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 72x72mm with SSR/Relay output) Comms RS485 Modbus RTU 38400 Max Baud Rate Mounting Style 72x72mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol

    27 pcs in stock

    $217.00
    $256.06 inclGST

  • FRTD-Transmitter-0-200-420-24, Pt100 , 4-20mA Transmitter, 0 to 200 Deg C, 24VDC Supply

    FRTD-Transmitter-0-200-420-24, Pt100 , 4-20mA Transmitter, 0 to 200 Deg C, 24VDC Supply

    10 pcs in stock

    Fastron FRTD-Transmitter-0-200-420-24, Pt100 , 4-20mA Transmitter, 0 to 200 Deg C, 24VDC Supply Class A Accuracy Steel Insulated Cable Low Long Term Drift Rated for 0 to 220 Deg C Max Spring Cable Connection 60mm Jaw Clip Specification Fastron Part Number FRTD-Transmitter-0-200-420-24 Sensor Type Pt100 to 4-20mA Transmitter No of Wires 3 Shaft Length N/A Shaft Thickness N/A Accuracy Class A Temperature Range 0 to 200 Deg C Span/ Zero Adjustment YES Weight 50g Factory Pack Qty 1

    10 pcs in stock

    $25.00
    $29.50 inclGST

  • SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-100-5A, 5 Amp, 100Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-50, 50Amp/0.333V Measurement, Class 1 Split Core CT's

    34 pcs in stock

    Fastron Electronics SCT-F24-50, 50Amp/0.333V Measurement, Class 1 Split Core CT's Features Quick Release Split Core System Cable Mount 333mV Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-50 Technology Split Core AC Current Transformer Ratio 50/333mV Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 333mV (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    34 pcs in stock

    $47.00
    $55.46 inclGST

  • Last stock! FK-1-75, Fuse Kit for 50-75 Amp F311 Single Phase Power Controller-Semiconductor Fuse Kit-Trent-Fastron Electronics Store

    FK-1-75, Fuse Kit for 50-75 Amp F311 Single Phase Power Controller

    5 pcs in stock

    FK-1-75, Fuse Kit for 50-75 Amp F311 Single Phase Power Controller Contains: 1 x 75AF 2 x M5x25mm Isolated Standoff Mounting Hardware Datasheet Product Datasheet Cross Reference Chart Insulated Standoffs

    5 pcs in stock

    $56.00
    $66.08 inclGST

  • Last stock! FK-3-70, aR Type Fuse Kit for 60-70 Amp F330, F430, F431 Three Phase Power Controller or VSD Drives-Semiconductor aR Type Fuse Kit-Trent-Fastron Electronics Store

    FK-3-70, aR Type Fuse Kit for 60-70 Amp F330, F430, F431 Three Phase Power Controller or VSD Drives

    1 pcs in stock

    FK-3-70, aR Type Fuse Kit for 60-70 Amp F330, F430, F431 Three Phase Power Controller or VSD Drives Contains: 3 x 75AF Trent Fuses 6 x M5x25mm Isolated Standoffs Mounting HaRdwaRe Datasheet Product Datasheet Cross Reference ChaRt Insulated Standoffs

    1 pcs in stock

    $116.00
    $136.88 inclGST

  • PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    9 pcs in stock

    Iskra Doo PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number PS11 Functions Auxiliary Contact for 3 Phase Motor Protection Switch, 1 x NO 6 Amp @ 230VAC, 1 x NC 6 Amp @ 230VAC Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @230VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    9 pcs in stock

    $18.00
    $21.24 inclGST

  • MVR 54N 400VAC, Voltage Monitoring Relay, 3 Phase 4 wire, 415VAC Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjutsable Upper and Lower Voltage Limits

    MVR 54N 400VAC, Voltage Monitoring Relay, 3 Phase 4 wire, 415VAC Over/Under Voltage Detection, 1 x CO SPDT 8 Amp Contact, Adjustable Timer Delay, Adjutsable Upper and Lower Voltage Limits

    9 pcs in stock

    Iskra Doo MVR 54N 400VAC Series Voltage Monitoring Relay MVR 54N Series serves to monitor voltage, phase failure and sequence in switchboards, protection of devices in 3-phase 4 wire mains Features Upper and lower level of monitoring voltage Adjustable time delay eliminates short voltage peaks and failures in the main Supply is done from monitored voltage Faulty state is indicated by red LED and by opening of output relay contact Output contact 1 x Changeover / SPDT 8 A /250 V AC1 In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay MVR 54 - supply from all phases which means that relay is functional also in case when one phase is faulty Variant MVR 54N - supply L1-N, means that relay monitors also failure of neutral wire 1-MODULE, DIN rail mounting Specification Technical Data MVR 54 MVR 54N Supply and measuring L1, L2, L3 L1, L2, L3, N Supply terminals L1, L2, L3 L1, N Supply/measured voltage 3 x 400 V / 50 Hz 3 x 400 V / 230 V /50 Hz Level Umax 105 - 125 % Un Level Umin 75 - 95 % Un Burden max. 2 VA Hysteresis 2 % Max. permanent overload AC 3 x 460 V AC 3 x 265 V Peak overload <1ms AC 3 x 500 V AC 3 x 288 V Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 8 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information Operating temperature -20 ... +55 °C Storage temperature -30 ... +70 °C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g 67 g Standards EN 60255-6, EN 61010-1 Datasheet Product Datasheet Application Notes Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines. In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.

    9 pcs in stock

    $95.00
    $112.10 inclGST

  • Last stock! AMB-DVO(+/-75mV)A-N, 96x48mm DC Ammeter DC Voltmeter +/-75mV Input, 110-240VAC supply, Large 4.1 Digit

    AMB-DVO(+/-75mV)A-N, 96x48mm DC Ammeter DC Voltmeter +/-75mV Input, 110-240VAC supply, Large 4.1 Digit

    5 pcs in stock

    Fastron Electronics AMB-DVO(+/-75mV)A-N, 96x48mm DC Ammeter DC Voltmeter +/-75mV Input, 110-240VAC supply, Large 4.1 Digit Adjustable Zero and Span Setting Adjustable Display Scaling Large 4.1 Digit 20.3mm (8 Inch) LED Display 250mS Response Time PC 94 UL V0 Each unit needs just 96 x 48mm Panel Space 90mm Depth CE Approved Specification Fastron Electronics Part Number AMB-DVO(+/-75mV)A-N Conditioner Output N/A Input +/-75mVDC Over Range x 1.5 Operating Temperature 0 - 60°C Supply Voltage 100 - 240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Display Type 4.1 Digit RED LED Mounting Style 96 x 48mm Panel Mount Case Material PC - UL 94 V0 Weight 320g Factory Pack Qty 1   Datasheet Product Datasheet Application Notes Panel Meters Blog Articles

    5 pcs in stock

    $129.00
    $152.22 inclGST

  • CN024D05, Slimline Relay, 3-12VDC Coil, 24VDC 3.5 Amp Load

    CN024D05, Slimline Relay, 3-12VDC Coil, 24VDC 3.5 Amp Load

    40 pcs in stock

    Crydom CN024D05, Slimline Relay, 3-12VDC Coil, 24VDC 3.5 Amp Load Features Output 3.5Amp @ 24VDC 3-12VDC Control input DIN Rail Mount Changeover Contact Ultra slim package CE Compliant to IEC 60664 IP67 Specification Crydom Part Number CN024D05 Switching Type 24VDC 3.5 Amp Load SSR Approvals UL, CE ROHS Yes (Details) Control Voltage 3-12VDC Load Current 3.5 Amp (rms) Special Feature LED Status Indicator Mounting Style Socket Mount (F41F-1Z-C2-5 12-14VAC/DC) Load Voltage Range 24VDC Load EMC Compliant Level 3 Termination Style PCB or Socket Mount Unit Weight 6g Factory Pack Qty 20   Datasheet Relay Datasheet F41F-1Z-C2-5 12-14VAC/DC Socket

    40 pcs in stock

    $42.15
    $49.74 inclGST

  • FRI8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    FRI8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    99 pcs in stock

    Fastron FRI 8-01/0.05, Current Monitoring Relay AC 0.05 - 0.5 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s. Features : Suitable for Current Transformer Monitoring Flexible adjustment by potentiometer, choise of 6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measured current Output contact: 1 x changeover 8 A 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI 8-01/1 Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 0.05 - 0.5 A (AC 50 Hz) Current Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 1.1 x Ipn Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output ?? Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS Datasheet Product Datasheet Application Notes Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.

    99 pcs in stock

    $57.00
    $67.26 inclGST

Login

Forgot your password?

Don't have an account yet?