Recommended products

4100 products

  • Last stock! Fast ONE AHF 50A-400V, Active Harmonic Filter, 50 Amp, 3 Phase + N, 400VAC +/-20%

    Fast ONE AHF 50A-400V-4W, Active Harmonic Filter & Static Var Generator, 35Kvar/50 Amp, 3 Phase + N, 400VAC +/-20%, WALL MOUNT

    1 pcs in stock

    Fast ONE AHF 50A-400V, Active Harmonic Filter & Static Var Generator, 35Kvar/50 Amp, 3 Phase + N, 400VAC +/-20%, WALL MOUNT For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. and for the filtering or control of Harmonic Distortion Features Automatic Power Factor Correction up to Cos φ = 0.99 Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty Modular Construction for Rack or Wall Mount Installtions Perfect for Residential Applications Stack multiple modules for larger Power Factor Correction Requirements   Specification Fastron Part Number Fast ONE AHF 50A-400V Function Reactive Power Correction & Active Harmonic Filter Rating 50 Amp @ 50 Deg C /35Kvar Nominal Voltage (Un) 400VAC Line to Line 50Hz Switch Delay Time Instant Correction/Inverter Based Desired Harmonic 0.99 IND - 0.99 CAP LCD Display Accuracy IGBT Temp, Grid Current Grid THDi, Grid PF, Grid Imbalance Current imbalance < 5%  Comms RS485 (Optional) Mounting Style Wall Mount Termination Style Screw Dimensions 486x183x550mm Weight 40kg Certification EN 61000-6-4:2007+A1:2011 EN 61000-6-2:2005 EN 61000-3-2:2014 EN 61000-3-3:2013+A1:2019 Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Datasheet User Manual

    1 pcs in stock

    $5,349.00
    $6,311.82 inclGST

  • HF121-12/0.4-25-7%K, 25kVar 400VAC 7% Detuned Reactor for Power Factor Correction Capacitor Banks-Detuning Reactor-Fastron Electronics-Fastron Electronics Store

    HF121-12/0.4-25-7%K, 25kVar 400VAC(1.53mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.53mH(400VAC) 2.457mH(525VAC)

    9 pcs in stock

    Fastron Electronics HF121-12/0.4-25-7%K, 25kVar 400VAC(1.53mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.53mH(400VAC) 2.457mH(525VAC) Specification Technical Features HF121-12/0.4-25-7%K Electrical Voltage 400V/525V Network Frequency 50/60Hz Inductance (mH @ 400VAC) 1.53mH Inductance (mH @ 525VAC) 2.457mH Nominal Power 25kvar Value of p% 7% (189Hz) Type of Conductor Aluminium/Copper(optional) Tolerance L 5% Linearity (5% L) 1.8 x In Isolation Voltage kV Maximum Room Temperature -10 to 45 Deg C Internal isolation Class F(155°C), Class H (180°C Optional) Maximum Overload Permanent 1.17 x In Temporary 2 x In Safety Protection Thermostat Opens at 90 °C Degree Protection IP00 Installation Indoor Standards EN-60289, IEC60076 Weight 30kg Datasheet Product Datasheet Installation Guide HF121 Series Installation Guide

    9 pcs in stock

    $525.00
    $619.50 inclGST

  • FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    99 pcs in stock

    Fastron FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s. Features : Suitable for Current Transformer Monitoring Flexible adjustment by potentiometer, choise of 6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measured current Output contact: 1 x changeover 8 A 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI 8-01/2 Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range -15 %; ? % Current Range 0.1 - 2 A (AC 50 Hz) Current Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 1.1 x Ipn Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output ?? Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Application Notes Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.

    99 pcs in stock

    $57.00
    $67.26 inclGST

  • FHR17-400/3, NH2/NT2/RT16-2 Fuse Disconnect Switch 690VAC, 400 Amp Max FHR17-400/3, NH2/NT2/RT16-2 Fuse Disconnect Switch 690VAC, 400 Amp Max

    FHR17-400/3, NH2/NT2/RT16-2 Fuse Disconnect Switch 690VAC, 400 Amp Max

    40 pcs in stock

    FHR17-400/3, NH2/NT2/RT16-2 Fuse Disconnect Switch 690VAC, 400 Amp Max Datasheet Product Datasheet

    40 pcs in stock

    $179.00
    $211.22 inclGST

  • FHR17-160/3, NH00 00C,NT00/00C,RT16-00/000 3 Pole Fuse Disconnect Switch 690VAC, 160 Amp Max FHR17-160/3, NH00 00C,NT00/00C,RT16-00/000 3 Pole Fuse Disconnect Switch 690VAC, 160 Amp Max

    FHR17-160/3, NH00 00C,NT00/00C,RT16-00/000 3 Pole Fuse Disconnect Switch 690VAC, 160 Amp Max

    38 pcs in stock

    FHR17-160/3, NH00 00C,NT00/00C,RT16-00/000 3 Pole Fuse Disconnect Switch 690VAC, 160 Amp Max Datasheet Product Datasheet

    38 pcs in stock

    $79.00
    $93.22 inclGST

  • FHR17-250/3, NH1/NT1/RT16-1 Fuse Disconnect Switch 690VAC, 250 Amp Max FHR17-250/3, NH1/NT1/RT16-1 Fuse Disconnect Switch 690VAC, 250 Amp Max

    FHR17-250/3, NH1/NT1/RT16-1 Fuse Disconnect Switch 690VAC, 250 Amp Max

    40 pcs in stock

    FHR17-250/3, NH1/NT1/RT16-1 Fuse Disconnect Switch 690VAC, 250 Amp Max Datasheet Product Datasheet

    40 pcs in stock

    $129.00
    $152.22 inclGST

  • FRS4-C40/480VAC (R), 4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts FRS4-C40/480VAC (R), 4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts

    FRS4-C40/480VAC (R), 4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts

    54 pcs in stock

    Trent FRS4-C40/480VAC (R),4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts Specifications   Trent part number FRS4-C40 3P+N 480VAC (R) Nominal Voltage (Un) 480VAC Maximum Operating Voltage (Uc) L-L : 960 V AC ; L-PE : 880VAC Voltage Protection Level (Up) L-L: ≤ 3.8kV; L-PE: ≤ 5.1kV No of Poles 3 + 0 Category IEC / EN / VDE Class II / Type 2 Location of use Sub Distribution Boards Protection modes L-L L-PE, High Energy MOV Additional Remote Contacts YES (4x) Protective element MOV Surge discharge rating Imax up to 40kA(8/20us) L-PE/L-L 320VAC / 20kA(8/20us) L-PE/L-L Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11   Datasheet Product Datasheet

    54 pcs in stock

    $119.00
    $140.42 inclGST

  • FTC002-A7B(RTC), PID Temperature Controller for HVAC, 71x29mm Cutout, 100-240VAC, 2 x Relay Outputs, Includes 4 x NTC or PT1000 Sensor Inputs FTC002-A7B(RTC), PID Temperature Controller for HVAC, 71x29mm Cutout, 100-240VAC, 2 x Relay Outputs, Includes 4 x NTC or PT1000 Sensor Inputs

    FTC002-A7B(RTC), PID Temperature Controller for HVAC, 71x29mm Cutout, 100-240VAC, 2 x Relay Outputs, Includes 4 x NTC or PT1000 Sensor Inputs

    10 pcs in stock

    Furison FTC002-A7B(RTC), PID Temperature Controller for HVAC, 71x29mm Cutout, 100-240VAC, 2 x Relay Outputs, Includes 4 x NTC or PT1000 Sensor Inputs 3-digit display suit refrigeration temperatures to 1 Degree Drip-proof / Dust-proof IP64 (front panel only) Each unit needs just 71 x 29mm panel space 3 minute delay protection Automatic 15 minutes ON, 30 minutes OFF on sensor failure Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking Ultra High temperature 99 - 120 Deg C Displays "HH" Specification Furison Part Number FTC002-A7B(RTC) Control Output 1 x SPST Relay 10A 250VAC (Compressor), 1 x SPST 8A 250VAC (Aux Relay) Input 4 x NTC or PT1000 Probe Cooling/Cooling Outputs 2 x 230VAC 10 Amp Relay Contact Mounting Style 75 x 34.5mm Panel Mount Supply Voltage 100-240VAC Termination Style Screw Weight 150g Factory Pack Qty 1 Certifications UL, CE   Datasheet Download Datasheet

    10 pcs in stock

    $87.00
    $102.66 inclGST

  • CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount-3 Phase AC Current Transformer-Hobut Howard Butler-Fastron Electronics Store

    CT105D-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, Din Rail Mount

    10 pcs in stock

    Hobut CT105D-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, Din Rail Mount Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Hobut Part Number CT105D-100/5-2.5/1 Technology AC Current Transformer Ratio 100/5 Aperture Size 21 x 25mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Unit Weight 450g Factory Pack Qty 9   Datasheet Product Datasheet  

    10 pcs in stock

    $123.00
    $145.14 inclGST

  • CTB 120 Series Core balanced CT's for Earth Leakage Detection, Various Sizes Selectable-Solid Core AC Current Transformer-Hobut-Fastron Electronics Store

    CTB 120, 120mm Diameter CTB Series Core Balanced/Toroid CT (CBCT) for AC Earth Leakage Detection, for RCR Series Hobut Core balanced CT’s

    12 pcs in stock

    Hobut CTB 35, 35Amp Measurement Core Balanced/Toroid CT's (CBCT) for AC Earth Leakage Detection Features Very low differential current measurement Applications Earth Leakage   Specification Hobut Part Number CTB 120 Technology Core Balanced/Toroid  (CBCT)  Aperture Size 120mm Sizes Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -15°C / 55°C Termination Style Maximum 2.5mm stranded or 4mm solid conductors Factory Pack Qty 3 Datasheet Product Datasheet Application Notes RCR-V30 Installation Guide

    12 pcs in stock

    $168.00
    $198.24 inclGST

  • CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount-3 Phase AC Current Transformer-Hobut Howard Butler-Fastron Electronics Store

    CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount

    10 pcs in stock

    Hobut CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount for MCCB Mounting Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Hobut Part Number CT105F-100/5-2.5/1 Technology AC Current Transformer Ratio 100/5 Aperture Size 21 x 25mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 100Amp x 1.2 Termination Style Screw Unit Weight 450g Factory Pack Qty 9   Datasheet Product Datasheet  

    10 pcs in stock

    $103.00
    $121.54 inclGST

  • LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel

    LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel

    50 pcs in stock

    GIC Controls, LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel   Features IP40 (IP66 with Gasket) 4-36VAC/DC 6 Digit Display 99999.9 Hours 37x24mm Panel Mount Two Mounting Hole Bezel Rectangular Cutout UL Approved Datasheet Product Datasheet

    50 pcs in stock

    $35.00
    $41.30 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account