Fast ONE AHF 50A-400V, Active Harmonic Filter & Static Var Generator, 35Kvar/50 Amp, 3 Phase + N, 400VAC +/-20%, WALL MOUNT
For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. and for the filtering or control of Harmonic Distortion
Features
Automatic Power Factor Correction up to Cos φ = 0.99
Overtemperature Alarm
Optional RS485 Comms
IEC 654-1, UL Approved
3 Year Fastron Electronics Warranty
Modular Construction for Rack or Wall Mount Installtions
Perfect for Residential Applications
Stack multiple modules for larger Power Factor Correction Requirements
Â
Specification
Fastron Part Number
Fast ONE AHF 50A-400V
Function
Reactive Power Correction & Active Harmonic Filter
Rating
50 Amp @ 50 Deg C /35Kvar
Nominal Voltage (Un)
400VAC Line to Line 50Hz
Switch Delay Time
Instant Correction/Inverter Based
Desired Harmonic
0.99 IND - 0.99 CAP
LCD Display Accuracy
IGBT Temp, Grid Current Grid THDi, Grid PF, Grid Imbalance
Current imbalance
<Â 5%Â
Comms
RS485 (Optional)
Mounting Style
Wall Mount
Termination Style
Screw
Dimensions
486x183x550mm
Weight
40kg
Certification
EN 61000-6-4:2007+A1:2011
EN 61000-6-2:2005
EN 61000-3-2:2014
EN 61000-3-3:2013+A1:2019
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013
Enclosure protection
IP21
Safety
According to EN 61 010-1, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Datasheet
User Manual
Fastron Electronics HF121-12/0.4-25-7%K, 25kVar 400VAC(1.53mH) 7% Detuned Reactor for Power Factor Correction Capacitor Banks, 1.53mH(400VAC) 2.457mH(525VAC)
Specification
Technical Features
HF121-12/0.4-25-7%K
Electrical
Voltage
400V/525V
Network Frequency
50/60Hz
Inductance (mH @ 400VAC)
1.53mH
Inductance (mH @ 525VAC)
2.457mH
Nominal Power
25kvar
Value of p%
7% (189Hz)
Type of Conductor
Aluminium/Copper(optional)
Tolerance L
5%
Linearity (5% L)
1.8 x In
Isolation Voltage
kV
Maximum Room Temperature
-10 to 45 Deg C
Internal isolation
Class F(155°C), Class H (180°C Optional)
Maximum Overload
Permanent
1.17 x In
Temporary
2 x In
Safety
Protection Thermostat
Opens at 90 °C
Degree Protection
IP00
Installation
Indoor
Standards
EN-60289, IEC60076
Weight
30kg
Datasheet
Product Datasheet
Installation Guide
HF121 Series Installation Guide
Fastron FRI8-01/2, Current Monitoring Relay AC 0.2 - 2A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply
FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s.
Features :
Suitable for Current Transformer Monitoring
Flexible adjustment by potentiometer, choise of
6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks
Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V
Supply is galvanically separated from measured current
Output contact: 1 x changeover 8 A
1-phase, 1-MODULE, DIN rail mounting
Applications :
Heating bars in sliding rails
Heating cables
Indication of current flow
Controlling of 1-phase motor consumption
Specification
Fastron Part Number
FRI 8-01/2
Voltage Range
AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz)
Operating Range
-15 %; ? %
Current Range
0.1 - 2 A (AC 50 Hz)
Current Trip Adjustment
Potentiometer
Setting Accuracy
5 %
Burden
max. 1.5 VA
Repeatability
1 %
Temperature Drift
0.1%/??C
Peak Overload (10s)
1.1 x Ipn
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
??
Number of contacts
1x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
??
Operating temperature
-20 ... ? ??C
Storage temperature
-30 ... ? ??C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE
Datasheet
Product Datasheet
Application Notes
Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.
Trent FRS4-C40/480VAC (R),4 Pole, Uc = 480VAC L-L 960VAC, L-PE 1360VAC, Type 2 (Class II) Surge Protection Device In 20kA, Imax 40kA, Pluggable, With 4 x Remote Contacts
Specifications
Â
Trent part number
FRS4-C40 3P+N 480VAC (R)
Nominal Voltage (Un)
480VAC
Maximum Operating Voltage (Uc)
L-L : 960 V AC ; L-PE : 880VAC
Voltage Protection Level (Up)
L-L: ≤ 3.8kV; L-PE: ≤ 5.1kV
No of Poles
3 + 0
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution Boards
Protection modes
L-L L-PE, High Energy MOV
Additional Remote Contacts
YES (4x)
Protective element
MOV
Surge discharge rating
Imax up to 40kA(8/20us) L-PE/L-L 320VAC / 20kA(8/20us) L-PE/L-L
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Â
Datasheet
Product Datasheet
Furison FTC002-A7B(RTC), PID Temperature Controller for HVAC, 71x29mm Cutout, 100-240VAC, 2 x Relay Outputs, Includes 4 x NTC or PT1000 Sensor Inputs
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FTC002-A7B(RTC)
Control Output
1 x SPST Relay 10A 250VAC (Compressor), 1 x SPST 8A 250VAC (Aux Relay)
Input
4 x NTC or PT1000 Probe
Cooling/Cooling Outputs
2 x 230VAC 10 Amp Relay Contact
Mounting Style
75 x 34.5mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Â
Datasheet
Download Datasheet
Hobut CT105D-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, Din Rail Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Hobut Part Number
CT105D-100/5-2.5/1
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Hobut CT105F-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount for MCCB Mounting
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Hobut Part Number
CT105F-100/5-2.5/1
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
GIC Controls, LC32F1 4-36VAC/DC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel
Â
Features
IP40 (IP66 with Gasket)
4-36VAC/DC
6 Digit Display
99999.9 Hours
37x24mm Panel Mount
Two Mounting Hole Bezel
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet