GIC Controls, LA22F1 90-264VAC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount, with two Mounting Holes Bezel
Â
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
37x24mm Panel Mount
Two Mounting Hole Bezel
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
Fastron HS212F & FCR-400-40R, Three Phase, Phase Angle Controller, 4-20mA,0-10V,500K POT Input, 400VAC, 36 Amp @ 40 Deg C, Din Rail Mount
4-20mA, 0-10V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212F & FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
36 Amp (rms) per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
DIN Rail Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Â
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet
Fastron FCR-400-40R, Three Phase Proportional Phase Control Module, 4-20mA,0-10V,500K POT Input, 400VAC, 40 Amp Per Phase, Also referred to as 3 Phase Voltage Regulator
4-20mA,0-10V, or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
40 Amp (rms) @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
3 Phase Proportional Controller + SSR/3 Phase Voltage Regulator
Mounting Style
Panel Mount
Load Voltage Range
180-400VAC +10%
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FCR-400-40R
Fastron Electronics GT-DVO(+75mV,-75mV)A1, Signal Isolator/Conditioner, +/-75mVDC input, 100-240VDC aux, 4-20mA BIPOLAR output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-DVO(+75mV,-75mV)A1
Control Output
4-20mA BIPOLAR
Input
+/-75mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100 - 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
LEM FRS 3000-SBI, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 3000-SBI
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
3000 Amp
Measurement Range
+/-9000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Iskra Doo KNK3053 12.5KVAR 525V 50HZ, Power Factor Correction Capacitor, 3 Phase, 90 x 210mm Dry Type, 3 x 48.1uF
Characteristics and utility
12.5kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR EnergÃa
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Iskra Part Number
KNK3053 12.5 KVAR 525V 50HZ
Technology
Dry Type, Low Loss, Self Healing
Dimensions
90 x 210mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
12.5 Kvar
Capacitance
3 x 48.1uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
13.7 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Feed Through Terminal
Unit Weight
1.4kg
Factory Pack Quantity
25
Â
Datasheet
Iskra PCF Catalogue
Capacitor Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Voltage Derating Tables
Hot Spot Testing
25kvar Specification Sheet
40kvar Specification Sheet
RTR Energia EA5251000500000 Power Factor Correction Capacitor, Single Phase, Dry Type 10 KVAR, 111.49uF, 525V, 50HZ, 85 x 225mm
Characteristics and utility
10 kVar @ 525V @ 50 Hz, 111.49uF
Discharge resistors Incorporated
Reactive power factor correction
Dry type
Connector type - single sided terminal
Indoor mounting
Safety
Overpressure disconnection system
Protection by internal fuses
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Polyurethane self-extinguishing resin V0, developed under standard UL 94 by RTR EnergÃa
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
RTR Energia Part Number
EA5251000500000
Technology
Dry Type, Low Loss, Self Healing
Dimensions
85 x 225mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
10 Kvar
Capacitance
111.4uF
Tolerance On Capacitance
-5% + 10%
Current (In)
15.9 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
DWCAP system (Patented) internal windings Displacement
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Unit Weight
0.9kg
Factory Pack Quantity
25
Â
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
ESCT-RC200-6000A, Rogowski Coil, 200mm Diameter, 85mV/kA Rated for 6000 Amp Recommended, 3 Meter Cable length
Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement).Â
Features
Rated insulation voltage 1000 V Cat III PD2
Accuracy Class 0.5 (IEC 61869-2)
Protection degree IP67
3 m output cable (other lengths available see page 8)
Ambient temperature 40 °C … +80 °C
Very flexible and thin coil: 6.1 mm
Slot for attaching the loop on the primary with a cable tie
An innovative patented clasp drastically reduces the positioning error near the closing
Internal shield for enhanced measurement accuracy at low primary currents.
Advantages
Thin, flexible, and light weight solution
Very low positioning error
Quick, non-intrusive and easy setup
A single sensor for a large current range without overload
Less influenced by external fields
Adaptable for a large range of cable diameters
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010; IEC 61010-2-32 ed.3: 2012
1) IEC 61869-1 ed1.0: 2007; IEC 61869-2: ed1.0: 2012
1) IEC 61869-6: draft 2016; IEC 61869-10: draft 2016
Specification
LEM Part Number
ESCT-RC200-6000A
Function
AC Current Measurement
Measuring Range
0 - 5,000 Amp RMS (Contact Us for Possible Replacement for wider range)
Secondary Voltage (Sensitivity)
85mV
Frequency Measuring Range
50-300kHz
Operating Voltage
Self Powered
Accuracy
0.5% from 25 to 5000 Amp
Phase Angle
< 0.004
Coil Diameter
20cm
Coil Circumference
Integrator to Coil Cable
3M Twisted Pair
Maximum Voltage
1000V Reinforced insulation according to EN 61010-1
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
7.4kV
Overload
300,000 Amp
Termination Style
2 Stripped Wires
Weight
130g
Factory Pack Qty
1
Certifications
Â
UL, ROHS
Datasheet
Product Datasheet
Application Notes
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modeling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ? 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ? 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
Â
Trent NBR-20 001 13-125A-500V-120kA-NH00, Semiconductor Type gG/gL Fuse, 160 Amp, 120kA, 500VAC, NH00, 78 x 46 x 29.5mm
Features
Square Body Size NH00
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
500Â V Voltage Rating
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-20 000 13-125A-500V-120kA-NH00
Fuse Type
I²t gG/gL Class
Nominal Voltage
500VAC @ 50Hz
Nominal Current (RMS + DC)
125Â Amp
Tested Breaking Capacity
120kA @ 690VAC
Dimensions
78 x 46 x 29.5mm
Hole Centers
N/A Blade Style
Mounting
Fuse Holder Mounting
Operating Temperature Range
-40°C / 125°C
Termination
Blade
Unit Weight
900g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Schurter 5500-2053, 1 Stage EMC (RFI) Line Filter for Single Phase systems
Features
Line filter in standard and medical version
1-stage - standard attenuation
Characteristics
Designed for standard applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Universal line filter for standard applications
Suitable for use in equipment according to IEC/UL 60950
Other Versions on Request
Version with wire connection
Version with varistor for overvoltage protection
Specification
Schurter Part Number
5500-2053
Rated Voltage
250V
Rated Current
3A
Filter Stages
1 Stage
Operating Temperature
-25°C to 85°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
0.25mA
Mounting
Panel Mount - Case 48
Material
Metal
Termination Style
Screw
Weight
275g
Factory Pack Qty
10
Protection Class
Suitable for appliances with protection class I acc. to IEC 61140
Isolation
1.7kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Schurter 3-108-714, 1 Stage 3 Phase + N EMC (RFI) Line Filter, 64 Amp, FMAD NEO, 520VAC, Very High Attenuation
Features
Line filter suitable for 3 Phase + N systems
Wide Temperature Range
Characteristics
Designed for demanding applications
Protection against interference voltage from the mains Possible interferences generated in the equipment are strongly attenuated
Suitable for use in equipment according to IEC/UL 60950
Line filter suitable for low current Inverter such as PV or battery storage systems
Specification
Schurter Part Number
3-108-714
Rated Voltage
520V 3 Phase
Rated Current
64A
Filter Stages
1 Stage
Operating Temperature
-40°C to 100°C
Filter Type
Very High Symmetrical and Asymmetrical Attenuation
Leakage Current
N/A
Mounting
Panel Mount - Case FF
Material
Metal
Termination Style
Screw
Weight
1.35kg
Factory Pack Qty
4
Protection Class
Suitable for equipment according to IEC/UL 60950
Isolation
1.3 - 2.75kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet