Recommended products

4100 products

  • Last stock! GT-LL2-D-4, Signal Transmitter/Conditioner, Load Cell, 2mV/V EX.5V input, 0-10V output, 22-60VAC/DC supply GT-LL2-D-4, Signal Transmitter/Conditioner, Load Cell, 2mV/V EX.5V input, 0-10V output, 22-60VAC/DC supply

    GT-LL2-D-4, Signal Transmitter/Conditioner, Load Cell, 2mV/V EX.5V input, 0-10V output, 22-60VAC/DC supply

    1 pcs in stock

    Fastron Electronics GT-LL2-D-4, Signal Transmitter/Conditioner, Load Cell, 2mV/V EX.5V input, 0-10V output, 22-60VAC/DC supply Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-LL2-D-4 Control Output 0-10V Input 2mV/V EX.5V Over Range N/A Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    1 pcs in stock

    $309.00
    $364.62 inclGST

  • Last stock! GMTA-DV1-A-RN, DC Voltage Transducer with Alarm, 0-50mVDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm

    GMTA-DV1-A-RN, DC Voltage Transducer with Alarm, 0-50mVDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm

    1 pcs in stock

    GMTA-DV1-A-RN, DC Voltage Transducer with Alarm, 0-50mVDC Input, 100-240VAC/DC Aux, 1 x Relay Alarm Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals, Voltages up to 60mV, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint. Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Part Number GMTA-DV1-A-RN Control Output 1 x SPST Alarms 3 Amp Input 0-50mVVDC Alarm Type 1 x SPST NO Relay 3 Amp Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    1 pcs in stock

    $303.00
    $357.54 inclGST

  • FRI8-02/1, Under Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI8-02/1, Under Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    FRI8-02/1, Under Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply

    2128 pcs in stock

    Fastron FRI8-02/1, Under Current Monitoring Relay AC 0.1 - 1 A, Adjustable delay 0.5 - 10 s, 1 x CO 10 Amp, Universal 24-240VAC 24VDC Aux Supply FRI 8 Series serves to monitor AC currents up to 16 Amp, and provides Relay alarm output with adjustable delay time 0.5 - 10s. Features : Suitable for Current Transformer Monitoring Flexible adjustment by potentiometer, choice of 6 Models: 0.05 - 0.5 A; 0.1 - 1 A; 0.2 - 2 A; 0.5 - 5 A; 0.8 - 8 A; 1.6 - 16 A Adjustable delay 0.5 - 10 s to eliminate short current peaks Possible to use current scanning from current transformer - up to 600 A Universal supply AC 24 - 240 V and DC 24 V Supply is galvanically separated from measured current Output contact: 1 x changeover 8 A 1-phase, 1-MODULE, DIN rail mounting Applications : Heating bars in sliding rails Heating cables Indication of current flow Controlling of 1-phase motor consumption Specification Fastron Part Number FRI8-02/1 Voltage Range AC 24 - 240 V, DC 24 V (AC 50 - 60 Hz) Operating Range Current Range 0.1 - 1 A (AC 50 Hz) Current Trip Adjustment Potentiometer Setting Accuracy 5 % Burden max. 1.5 VA Repeatability 1 % Temperature Drift 0.1%/??C Peak Overload (10s) 1.1 x Ipn Time delay T1 max. 500 ms Time delay T2 adjustable 0.1-10 s Output ?? Number of contacts 1x changeover/ SPDT (AgNi / Silver Alloy) Rating 10 A / AC1 Breaking capacity 2500 VA / AC1, 240 W / DC Inrush current 10 A Switching voltage 250 V AC1 / 24 V DC Min. breaking capacity DC 500 mW Indication of state red LED Mechanical life 1 x 107 Electrical life (AC1) 1 x 105 Other information ?? Operating temperature -20 ... ? ??C Storage temperature -30 ... ? ??C Electrical strength 4 kV (supply - output) Operating position any Mounting DIN rail EN 60715 Protection degree IP 40 from front panel / IP 10 terminals Overvoltage cathegory III. Pollution degree 2 Max. cable size (mm )2 solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5 Dimensions 90 x 17,6 x 64 mm Weight 69 g Standards EN 60255-6, EN 61010-1, RoHS, CE Datasheet Product Datasheet Application Notes Monitoring relay FRI serves to monitor current level in single phase AC circuits. Due to its fluent adjustment of release current, it is predestined for applications with necessity of current flow indication, and can be used as precedence relay. Output relay is off in normal state. In case the set current level is exceeded, it switches. Multivoltage supply is an advantage.

    2128 pcs in stock

    $65.00
    $76.70 inclGST

  • Last stock! GMTA-DV6-D-RN, DC Voltage Transducer with Alarm, 0-300VDC Input, 22-60VAC/DC Aux, 1 x Relay Alarm

    GMTA-DV6-D-RN, DC Voltage Transducer with Alarm, 0-300VDC Input, 22-60VAC/DC Aux, 1 x Relay Alarm

    1 pcs in stock

    GMTA-DV6-D-RN, DC Voltage Transducer with Alarm, 0-300VDC Input, 22-60VAC/DC Aux, 1 x Relay Alarm Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint. Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Part Number GMTA-DV6-D-RN Control Output 1 x SPST Alarms 3 Amp Input 0-300VDC Alarm Type 1 x SPST NO Relay 3 Amp Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    1 pcs in stock

    $303.00
    $357.54 inclGST

  • DRD1230F40, Rectifier Diode PUK, 1260Amp, 4000V, 74/26

    DRD1230F40, Rectifier Diode PUK, 1260Amp, 4000V, 74/26

    24 pcs in stock

    Dynex DRD1230F40, Rectifier Diode PUK, 1260Amp, 4000V, 74/26 Capsule Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Dynex Part Number DRD1230F40 Vrrm 4000V Diode Configuration Diode Capsule (PUK) IF(av) @ 100 Deg C 1225 Amp Package Size ø74 x 26mm Itsm 20 kA VF(to) 0.82V Tj(max) 160°C rF 0.29mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-c) (double sided cooled 180°sin) 0.022°C/W R th(c-h) (double sided cooled) 0.004°C/W Weight 600g Clamping Force 18 - 22kN Factory Pack Qty 12 Certification ROHS Dynex Headquarters UK Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement Dynex 2022 Shorform Catalogue Heatsink Heatsink Profiles

    24 pcs in stock

    $935.00
    $1,103.30 inclGST

  • DG406BP25, GTO Thyristor (SCR) Capsule (PUK), 400 Amp, 2500V, 27 x 64mm-Thyristor PUK-Dynex Semiconductor Limited-Fastron Electronics Store

    DG406BP25, GTO Thyristor (SCR) Capsule (PUK), 400 Amp, 2500V, 27 x 64mm

    24 pcs in stock

    Dynex DG406BP25, GTO Thyristor (SCR) Capsule (PUK), 400 Amp, 2500V, 27 x 64mm Features Very low forward voltage drop Very low leakage current International standard package 64/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Dynex Part Number DG406BP25 Vrrm 2500V Diode Configuration GTO Thyristor Capsule (PUK) IF(av) @ 80 Deg C 400 Amp Package Size ø64 x 26mm Itsm 8 kA V(TM) 2.5V Tj(max) 125°C Gate Terminals With 400mm Gate Leads R th(j-c) (double sided cooled 180°sin) 0.041°C/W R th(c-h) (double sided cooled) 0.009°C/W Weight 600g Clamping Force 11 - 15kN Factory Pack Qty 6 Certification ROHS Dynex Headquarters UK Datasheet Product Datasheet Alternatives N1159NC400 Contact Us for Possible Replacement Dynex 2022 Shorform Catalogue Heatsink Heatsink Profiles

    24 pcs in stock

    $1,526.00
    $1,800.68 inclGST

  • DCR1260F42, Thyristor(SCR) PUK, 1260Amp, 4200V, 74/26-Thyristor PUK-Dynex Semiconductor Limited-Fastron Electronics Store

    DCR1260F42, Thyristor(SCR) PUK, 1260Amp, 4200V, 74/26

    24 pcs in stock

    Dynex DCR1260F42 Thyristor(SCR) Capsule, 1260Amp, 4200V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Dynex Part Number DCR1260F42 Vrrm 4200V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 60 Deg C 1260 Amp Package Size ø74 x 26mm Itsm 16.8 kA VF(to) 0.91V Tj(max) 125°C rF 0.611mΩ Gate Terminals With 400mm Gate Leads R th(j-c) (double sided cooled 180°sin) 0.0184°C/W R th(c-h) (double sided cooled) 0.004°C/W Weight 600g Clamping Force 20 - 25kN Factory Pack Qty 6 Certification ROHS Dynex Headquarters UK Datasheet Product Datasheet Alternatives N1159NC400 Contact Us for Possible Replacement Dynex 2022 Shorform Catalogue Heatsink Heatsink Profiles

    24 pcs in stock

    $969.00
    $1,143.42 inclGST

  • SCT-F16-150-40mA(SCT-F16-150-040A), 150/40mA Amp Measurement, Class 1 Split Core CT's SCT-F16-150, 150/0.333V Measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F16-150-40mA(SCT-F16-150-040A), 150/40mA Amp Measurement, Class 1 Split Core CT's

    16 pcs in stock

    Fastron Electronics SCT-F16-150-40mA(SCT-F16-150-040A), 150/40mA Amp Measurement, Class 1 Split Core Current Transformer, 16mm Aperture Features Quick Release Split Core System Cable Mount 40mA Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-150-40mA(SCT-F16-150-040A) Technology Split Core AC Current Transformer Ratio 150/40mAmp Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 1 Output 40mA Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    16 pcs in stock

    $48.00
    $56.64 inclGST

  • AI-PMUL + ART-B22-D70, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D70-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter

    ART-B22-D70-SP3 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter

    41 pcs in stock

    LEM ART-B22-D70-SP3 + AI-PMUL Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Included Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D70-SP3 + AI-PMUL Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Applicaton Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.

    41 pcs in stock

    $524.00
    $618.32 inclGST

  • Last stock! AI-PMUL + ART-B22-D300, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter-Rogowski Coil-LEM International SA-Fastron Electronics Store ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter

    ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter

    1 pcs in stock

    LEM ART-B22-D300-SP4 + AI-PMUL, Single Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 30cm Diameter The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D300-SP4 + AI-PMUL Function Single Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 30cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 4.5M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications   UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.  

    1 pcs in stock

    $554.00
    $653.72 inclGST

  • Last stock! UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    4 pcs in stock

    Iskra Doo UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms (U)MT version = Ring type terminal block Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number UMT540-HSHFNAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 4 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations Ring Type Terminal Block Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software

    4 pcs in stock

    $2,099.50
    $2,477.41 inclGST

  • Shunt 1A/60mV DC Current Shunt, 60mV output, Form B Class 0.5

    Shunt 1A/60mV DC Current Shunt, 60mV output, Form B Class 0.5

    10 pcs in stock

    Rishabh Shunt 1A/60mV DC Current Shunt, 60mV output, Form B Class 0.5 Features Low Cost Instantaneous measurement Applications Industrial Electrical Installatons Feedback Control DC Current Measurement Specification Rishabh Part Number Shunt 1A/60mV Nominal Current Ipn (DC) up to 10 Amp Overload Capacity 1.2 x Ipn continuous (5 x Ipn 5 seconds) Mounting Style Panel Mount Operating Temperature Range -25°C / 65°C Standards DIN EN 60 051, DIN EN 50 022-35 Unit Weight up to 7kg Factory Pack Qty 1   Datasheet Product Datasheet  

    10 pcs in stock

    $28.00
    $33.04 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account