Recommended products

4100 products

  • FGM6DC-3PLC-320 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-320 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-320 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    8 pcs in stock

    Trent FGM6DC-3PLC-320 315A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 315 Amp, 1500VDC, 3 POLE CONNECTING TYPE Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-320 315A Functions DC MCCB Nominal Voltage 1500VDC Nominal Current Range 315 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 3.3kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet CE Declaration

    8 pcs in stock

    $325.00
    $383.50 inclGST

  • FGM6DC-3PLC-320 100A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 100 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-320 100A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 100 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-320 100A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 100 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    8 pcs in stock

    Trent FGM6DC-3PLC-320 100A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 100 Amp, 1500VDC, 3 POLE CONNECTING TYPE Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PLC-320 100A Functions DC MCCB Nominal Voltage 1500VDC Nominal Current Range 100 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 3.3kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet CE Declaration

    8 pcs in stock

    $325.00
    $383.50 inclGST

  • FGM6DC-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1500VDC FGM6DC-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1500VDC

    FGM6DC-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1500VDC

    8 pcs in stock

    Trent FGM6DC-630 500A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 500 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-630 500A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 500 Amps @ 40 Deg C Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 1,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals TUV, CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Dimensions W98xH310xD130mm Weight 6.6kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    8 pcs in stock

    $595.00
    $702.10 inclGST

  • FGM6DC-630 450A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 450 Amp, 1500VDC FGM6DC-630 450A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 450 Amp, 1500VDC

    FGM6DC-630 450A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 450 Amp, 1500VDC

    8 pcs in stock

    Trent FGM6DC-630 450A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 450 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-630 450A Functions 2 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 450 Amps @ 40 Deg C Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 1,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals TUV, CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Dimensions W98xH310xD130mm Weight 6.6kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    8 pcs in stock

    $595.00
    $702.10 inclGST

  • FGM6DC-2PL-320 280A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 280 Amp, 1000VDC FGM6DC-2PL-320 280A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 280 Amp, 1000VDC

    FGM6DC-2PL-320 280A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 280 Amp, 1000VDC

    11 pcs in stock

    Trent FGM6DC-2PL-320 280A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 280 Amp, 1000VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-320 280A Functions 2 Pole DC MCCB Nominal Voltage 1000VDC Nominal Current Range 280 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 20kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 2.2kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet CE Declaration

    11 pcs in stock

    $275.00
    $324.50 inclGST

  • Last stock! FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    FGM6DC-3PLC-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC, 3 POLE CONNECTING TYPE

    4 pcs in stock

    Trent FGM6DC-3PL-400 350A, 3 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 25kA 350 Amp, 1500VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 3 Pole Disconnect 25kA Short Circuit Rating @1500VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-3PL-400 350A Functions 3 Pole DC MCCB Nominal Voltage 1500VDC Nominal Current Range 350 Amps Trip Delay Time < 50ms Rated Impulse Voltage 12kV Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu (Ics/Icu) 25kA Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)  Weight 8.5kg Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet CE Declaration

    4 pcs in stock

    $495.00
    $584.10 inclGST

  • Last stock! FGM6DC-2PL-320 140A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 140 Amp, 1000VDC FGM6DC-2PL-320 140A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 140 Amp, 1000VDC

    FGM6DC-2PL-320 140A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 140 Amp, 1000VDC

    3 pcs in stock

    Trent FGM6DC-2PL-320 140A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 140 Amp, 1000VDC Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock Features : 2 Pole Disconnect 20kA Short Circuit Rating @1000VDC Suitable for DC Power Systems Including Solar and Battery Standards : IEC/EN 60947-3 IP20 (IP40 Installed) IEC 61008 Specification Trent Part Number FGM6DC-2PL-320 140A Functions 2 Pole DC MCCB Nominal Voltage 1000VDC @ 50/60Hz Nominal Current Range 140 Amps Trip Delay Time < 50ms Operating Temperature -35 to 70 Deg C Electrical Operations 5,000 Ops Insulation Voltage 1500V Short Circuit Current Ics=Icu 20kA @ 1000VDC Approvals CE Standards GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed) Weight 2.2kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet CE Declaration

    3 pcs in stock

    $275.00
    $324.50 inclGST

  • CD 100-S/SP5, O/L Hall Effect Current Sensor, 2 x 1000 Amp, +/-5V Output

    CD 100-S/SP5, O/L Hall Effect Current Sensor, 2 x 1000 Amp, +/-5V Output

    19 pcs in stock

    LEM CD 100-S/SP5, O/L Hall Effect Current Sensor, 2 x 1000 Amp, +/-5V Output Features Bandwidth DC to 5kHz Closed loop transducer using Hall effect (Compensated) Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Single or 3 Phase Inverter Propulsion and Breaking Chopper Propulsion Converter Auxiliary Converter Railway Security System Specification LEM Part Number CD100-S/SP5 Technology Closed Loop Hall Effect Aperture ø40mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 2 x1000 Amp Output +/-5 V Isolation 6 kV Bandwidth DC-5 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 2.5% Unit Weight 1kg Factory Pack Quantity 10   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    19 pcs in stock

    $9,500.00
    $11,210.00 inclGST

  • Last stock! DC-0-50-420B-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Bipolar output, 24VDC supply DC-0-50-420B-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Bipolar output, 24VDC supply

    DC-0-50-420B-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Bipolar output, 24VDC supply

    3 pcs in stock

    DC-0-50-420B-1.0, Hall Effect DC Current Transducer, 0-50 Amp DC, 4-20mA Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-50 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-50-420B-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-50 Amp Response Time < 1uS Output Bipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6   Datasheet Product Datasheet

    3 pcs in stock

    $385.00
    $454.30 inclGST

  • DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture

    DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture

    9 pcs in stock

    DCBT-050-24-420, Hall Effect DC Current Transducer, +/-50 Amp DC, 4-20mA bipolar output, 24VDC supply, 20mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp DC, 4-20 mA Bipolar Output Features ⌀20mm Aperture DC Bipolar Measurement 4-20mA analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DCBT-050-24-420 Technology  DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 1uS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 120g Factory Pack Qty 6   Datasheet Product Datasheet

    9 pcs in stock

    $345.00
    $407.10 inclGST

  • Last stock! DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply

    DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply

    3 pcs in stock

    DC-0-5-010-1.0, Hall Effect DC Current Transducer, 0-5 Amp DC, 0-10V Bipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-5 Amp DC, 4-20 mA Bipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Bipolar Measurement 0-10V analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-5-010-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-5 Amp Response Time < 1uS Output Bipolar 0-10V Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6   Datasheet Product Datasheet

    3 pcs in stock

    $385.00
    $454.30 inclGST

  • ACSP-200-420, Loop Powered Split Core AC Current Transducer, 200 Amp AC, 4-20mA Average RMS Output, 31mm aperture ACSP-200-420, Loop Powered Split Core AC Current Transducer, 200 Amp AC, 4-20mA Average RMS Output, 31mm aperture

    ACSP-200-420, Loop Powered Split Core AC Current Transducer, 200 Amp AC, 4-20mA Average RMS Output, 31mm aperture

    6 pcs in stock

    ACSP-200-420, Loop Powered Split Core AC Current Transducer, 200 Amp AC, 4-20mA Average RMS Output, 31mm aperture, SCT011-200 Compact and versatile Loop Powered Split Core AC Current Transducer, Comes with 4-20mA/0-5V, or 4-20mA Average RMS Analogue Output Features ⌀31mm Aperture Split Core AC Average RMS Measurement +/-10V analogue output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Loop Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number ACSP-200-420 Technology AC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage Loop Powered  Nominal Current (DC) 200 Amp RMS Response Time < 200mS Output 4-20mADC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6   Datasheet Product Datasheet

    6 pcs in stock

    $249.00
    $293.82 inclGST

Login

Forgot your password?

Don't have an account yet?