Furison FTC052-A3C, PID Temperature Controller for HVAC, 87.6x34.5mm (71x29m Cutout), 100-240VAC, 4 x Relay Outputs (one prgrammable), 3 x NTC Inputs, 2 x Digital Inputs, Includes single NTC Sensor Only
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FTC052-A3C
Control Output
4 x SPST Relay 10A(Resistive)for Heat/Cool/Compressor/Fan/Alarm
Input
3 x NTC Probe ( 1 only sensor Included with 2 Meter wire length)
Cooling/Cooling Outputs
4 x 230VAC 10 Amp Relay Contact
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Â
Datasheet
Download Datasheet
Trent DSTO-MAU-5F-R-0.8M-N-H-SP1, Power Distribution Unit (PDU) with IEC Inlet Male AU Plug via 10.5M Cable, to 5 x F/C13 Outlet, 240VAC @ 10 Amp with Rocker Switch, Rack Mounted, with Overload Protection, MOQ = 10pcs (if not in stock), Metal Construction
Features
1 x Male Australian Plug in 5 x F/C13 out, Ganged Distribution Outlet
Male Australian Plug & F Socket Socket acc to IEC 60320-1
70 °C pin Temperature
Rocker Switch Protected
Suitable for use in equipment according to IEC/UL 60950
OTHER SIZES CAN BE MADE TO ORDER
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 70 °C, 10A, Protection Class I
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Â
Specification
Trent Part Number
DSTO-MAU-5F-R-0.8M-N-H-SP1 (PDUC1305ST10AUG)
Rated Voltage
250V
Rated Current
10A
No of Outlets
5
Operating Temperature
-25°C to 120°C
Filter Type
N/A
Overload Protection
YES
Line Switch
Rocker Switch - 10 Amp (red Illumination)
Mounting
Rear Mounted with Plastic Hooks
Material
Powder Coated Metal black
Termination Style
1 x Male AU Plug Inlet (via 0.5M Cable), 5 x F/C13 Outlet
Weight
2000g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV (L-N, L/N-E)
VDE/UL/CSA/CE/ROHS
Â
Datasheet
Product Datasheet
Â
Westcode - IXYS, B0713YC2500, Thyristor (SCR) Capsule 495Amp, 2500V, 41/14, Drop In Replacement for N606Y
Features
Very low forward voltage drop
Very low leakage current
International standard package
41/14 Package
Press Mounted
Double or Single Sided Cooling
Applications
Power Supplies
Rectifier for drives applications
Controlled Rectifiers
AC Switch
Battery Chargers
Phase Controllers
Water Cooled AC switches
Power Factor Correction
Specification
Westcode-IXYSÂ Part Number
B0713YC2500
Vrrm
2500V
SCR Configuration
Thyristor(SCR) Capsule PUK
IF(av) @ 85 Deg C
495Â Amp
Package Size
ø41 x 14mm
Itsm
7.1Â kA
Gate Terminals
Faston 4.8 x 0.8mm & 2.8 x 0.8mm
Weight
90g
Factory Pack Qty
12
Certification
ROHS
IXYS Headquarters
USA
Datasheet
Product Datasheet
Heatsink
Heatsink Profiles
Â
Â
Trent FRS4-D20 320V 2P (2+0) (R), Class II/Type 2, AC Surge Protection Device (SPD) with Remote Contacts, 2 Pole In = 10/20kA L-N, 230VAC, DIN Rail Mount, L/N-PE, High Energy MOV Type
Specifications
Â
Trent part number
FRS4-D20 320V 2P (2+0) (R)
Nominal Voltage (Un)
230VAC
Maximum Operating Voltage (Uc)
320VAC
Voltage Protection Level (Up)
<1.2kV
No of Poles
2
Category IEC / EN / VDE
Class II / Type 2
Location of use
Sub Distribution BoardsÂ
Protection modes
L/N-PE, High Energy MOV
Additional Remote Contacts
YES
Protective element
MOV
Surge discharge rating
Imax up to 20kA(8/20us) L/N-PE 320VAC
Internal protection and safety
Thermal disconnector in each MOV
Standards
IEC/EN 61643-11
Â
Datasheet
Product Datasheet
Trent I^2t (aR) Blade Style Semiconductor Fuse, 315 Amp, 690VAC, Square Body, Size 1, 200kA (78mm Hole Centers) F170M4010
Features
Square Body, Size 1
Wide Range of I^2t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
ApplI^2tions
Protection of High Powered Semiconductors according to I^2t
Short Circuit Protection
DC or AC Motor I^2t Protection
Battery Fuse
Specification
Trent Part Number
F170M4010
Fuse Type
I^2t AR Class
Nominal Voltage
690VAC @ 50Hz
I^2t Rating (660V)
42000A^2/s
Nominal Current (RMS DC)
315 Amp
Tested Breaking Capacity
200kA (78mm Hole Centers) @ 690VAC
Dimensions
53 x 104 x 53mm
Hole Centers
78mm
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40DegC / 125DegC
Watt Loss
58W
Termination Style
M10
Unit Weight
350g
Factory Pack Qty
10
Â
Datasheet
Product Datasheet
Fastron HS212 & FCR-400-40R, Three Phase, Phase Angle Controller, 4-20mA,0-10V,500K POT Input, 400VAC, 20 Amp @ 40 Deg C
4-20mA,0-10V, 0-10V or 500K POT Proportional Phase Control Input
Ratings from 25A to 120 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
HS212 & FCR-400-40R
Switching Type
Phase Angle (Random Crossing)
Control Voltage
4-20mA,0-10V,500K POT Proportional Input
Load Current
20 Amp (rms) per phase @ 40 Deg C
Surge Capability
500Amp (peak)
Special Feature
Three Phase Proportional Controller
Mounting Style
Panel Mount
Load Voltage Range
350-400VAC +15% (460VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
100 x 135 x 130mm
Unit Weight
1500g
Factory Pack Qty
20
Â
Datasheet
FCR Series Voltage Regulators
HS212 Datasheet
HS212, Heatsink 110mm, Milled, Drilled and Tapped for Single & 3 Phase SSR, 1°C/W
Specifications
3 x 20 Amp @ 40 Deg C
Panel Mount
Datasheet
Product Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.Â
4400.0129 T11-211-10.235, Thermal Circuit Breaker (CBE) for Electrical Appliance, 240VAC/48VDC, 10.235 Amp, 2kA, Threaded neck type, Reset Type, Quick Connect Terminals
Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of electrical appliances, and as a disconnector in case of equipment failure/malfunction
Description
Threaded neck type
Thermal circuit breaker
1-pole - Power tools
Reset type
Quick connect terminals 6.3 x 0.8 mm
Features :
< 3mS Trip Delay Time
1 Pole Disconnect
2kA Short Circuit Rating
Suitable for 500VDC Isolation
Applications:
Power Tools
Household Equipment
Power Supplies and Chargers
Industrial Appliances
Standards :
IEC 60934
2 x Ir: 500 Cycles
500VDC Insulation Resistance
1.5kV (50Hz) Dielectric Strength
Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
@ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
Specification
Schurter Part Number
4400.0129 T11-211-10.235
Functions
1 Pole Thermal Circuit Breaker, Reset Type
Nominal Voltage
240VAC @ 50Hz or 48VDC
Nominal Current Range
10.235 Amp RMS
Trip Delay Time
< 3ms
Rated Frequency
50/60 Hz
Operating Temperature
-5 to 60 Deg C
Insulation Resistance
500VDC
Dielectric Strength
1.5kV (50Hz)
Short Circuit Current
2kA
Approvals
UL, CSA
Standards
IEC 6094
Weight
10g
Enclosure Material
UL94
Factory Pack Qty
1
Â
Datasheet
Product Datasheet
Â
Fastron FY3 Series, Phase/Burst Controller for Primary Control of Transformer (Phase angle mode only), Voltage/Current/Power Limit Modes, For 3 Wire or 4 Wire Loads, 400VAC, 50 Amps per Phase @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/0-10V/1-5V input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Â
Specification
Fastron Part Number
FY3 Series
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V
Load Current
50-500 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Soft Start
N/A
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Â
Technical Docs
Brochure
User Guide
Modbus Protocol Guide
Modbus Register Map
Video for How to Set Current/Voltage/Power limit
Fastron FY3 Series, Phase/Burst Controller for Primary Control of Transformer (Phase angle mode only), Voltage/Current/Power Limit Modes, For 3 Wire or 4 Wire Loads, 400VAC, 50 Amps per Phase @ 50 Deg C, Modbus RTU
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
Made in China, Low cost
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/0-10V/1-5V input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium Frame
Removable Cover
Modbus RTU
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Â
Specification
Fastron Part Number
FY3 Series
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA/0-10V/0-5V
Load Current
50-500 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
1 x NO Relay Contacts
Special Feature
Internal Fuse, Current Limit, Power Limit
Comms
Modbus RTU
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
230VAC +/-10%
Soft Start
N/A
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Â
Technical Docs
Brochure
User Guide
Modbus Protocol Guide
Modbus Register Map
Video for How to Set Current/Voltage/Power limit
LEM LTC 1000-SF/SP4 Series Open Loop AC/DC Hall Effect Sensor
Features
Drop in replacement for LT 1000-SI/SP71
Bipolar and insulated current measurement up tp 3000 Amp
Current output
Bandwidth DC to 100kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Railway Equipment
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LTC 1000-SF/SP4
Technology
Closed Loop Hall Effect
Aperture
ø42mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
1000 Amp
Measurement Range
+/- 3000 Amp
Output
250 mA
Isolation
13.4 kV
Bandwidth
DC-100 kHz
Mounting Style
Panel Mount (with Feet)
Operating Temperature Range
-10°C / 85°C
Accuracy
0.4%
Termination Style
Faston 6.3 x 0.8mm
Unit Weight
900g
Factory Pack Quantity
6
Datasheet
Product Datasheet
Application Notes