Recommended products

4026 products

  • SCT-F24-200-5A, 5 Amp, 200Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-200-5A, 5 Amp, 200Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-200-5A, 5 Amp, 200Amp Measurement, Class 1 Split Core CT's

    110 pcs in stock

    Fastron Electronics SCT-F24-200-5A, 200/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-200-5A Technology Split Core AC Current Transformer Ratio 200/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 200Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    110 pcs in stock

    $44.20
    $52.16 inclGST

  • HDR-15-24, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 24VDC @ 630mA output-Power Supply-Meanwell-Fastron Electronics Store HDR-15-24, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 24VDC @ 630mA output

    HDR-15-24, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 24VDC @ 630mA output

    112 pcs in stock

    Meanwell Universal Input HDR-15-24, Universal Din Rail Mount Power Supply, 85-264VAC or 120-370VDC input, 24VDC @ 630mA output Supply Voltage: 85-264VAC or 120-370VDC Output Voltage: 24V Output Current: 630mA Short Circuit, Overload, Overcurrent, Overvoltage Protected Suited to Rogowski Coils, Wi-LEM Mesh Node, Mesh Gate, WiZone, Wi-Temp, Wi Pulse Datasheet Product Datasheet

    112 pcs in stock

    $26.50
    $31.27 inclGST

  • SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's

    SCT-F16-100-5A, 100/5Amp Measurement, Class 1 Split Core CT's

    87 pcs in stock

    Fastron Electronics SCT-F16-100-5A, 5 Amp Output, 100Amp measurement Split Core Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F16-100-5A Technology Split Core AC Current Transformer Ratio 100/5A Aperture Size ø 15 mm VA Rating 1VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    87 pcs in stock

    $45.00
    $53.10 inclGST

  • SCT-F24-250-5A, 5 Amp, 250Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-250-5A, 5 Amp, 250Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-250-5A, 5 Amp, 250Amp Measurement, Class 1 Split Core CT's

    32 pcs in stock

    Fastron Electronics SCT-F24-250 250/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    32 pcs in stock

    $44.20
    $52.16 inclGST

  • Last stock! SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's

    SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's

    1 pcs in stock

    Fastron Electronics SCT-F50-400-5A, 5 Amp, 400Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-400-5A Technology Split Core AC Current Transformer Ratio 400/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    1 pcs in stock

    $110.55
    $130.45 inclGST

  • SCT-F24-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store SCT-F24-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F24-300-5A, 5 Amp, 300Amp Measurement, Class 1 Split Core CT's

    790 pcs in stock

    Fastron Electronics SCT-F24-300-5A, 300/5 Amp Class 1 Series Current Transformer Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F24-300-5A Technology Split Core AC Current Transformer Ratio 300/5 Amp Aperture Size ø 24 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 300Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 100g Factory Pack Qty 9   Datasheet Product Datasheet Application Notes Installation Guide

    790 pcs in stock

    $44.20
    $52.16 inclGST

  • 04F-SD-NO-AL, AC Current Switch, Range 1-200Amp Self Powered, 10% Accuracy, Minimum Threshold 0.5 +/-0.2Amp Average RMS Current Sensing, Normally Open Contacts, 1Amp @ 240VAC Adjustable Trip. Replaces Dwyer CCS-111100 04F-SD-NO-AL, AC Current Switch, Range 1-200Amp Self Powered, 10% Accuracy, Minimum Threshold 0.5 +/-0.2Amp Average RMS Current Sensing, Normally Open Contacts, 1Amp @ 240VAC Adjustable Trip. Replaces Dwyer CCS-111100

    04F-SD-NO-AL, AC Current Switch, Range 1-200Amp Self Powered, 10% Accuracy, Minimum Threshold 0.5 +/-0.2Amp Average RMS Current Sensing, Normally Open Contacts, 1Amp @ 240VAC Adjustable Trip. Replaces Dwyer CCS-111100

    254 pcs in stock

    Fastron 04F-SD-NO-AL, AC Current Switch, Rangege 1-200Amp Self Powered, 10% Accuracy, Minimum Threshold 0.5 +/-0.2Amp Average RMS Current Sensing, Normally Open Contacts, 1Amp @ 240VAC Adjustable Trip. Replaces Dwyer CCS-111100 Compact and versatile current switches for detection of AC Currents, Multirange 1-10Amp, 10-50Amp, 50-200Amp via jumper Features Self Powered Multirange selector Panel mounting Eliminates insertion loss Isolated plastic case recognised according to UL94-V0 Advantages Highly accurate low current measurement down to 1Amp High isolation between primary and secondary circuits Easy installation Applications Fault Detection Motor or Fan Protection Application Domain Energy and Automation Specification Fastron Part Number 04F-SP-NO-AL Technology Split Core AC Current Transformer Alarm Type NO Relay 1Amp @ 240VAC Supply Voltage Self Powered Load Current (RMS) Multirange 1-200Amp Trip Point Adjustable Isolation 2kV (AC, 50Hz, 1 min) Bandwidth 50/60Hz Mounting Style Panel Mount Operating Temperature Range -25°C / 70°C Accuracy 10% (Minimum Threshold 0.5 +/-0.2 Amp) Termination Style Screw Terminals Unit Weight 200g Certifications UL E320368, CE, Rohs compliant   Datasheet Product Datasheet Replaces Dwyer CCS-111100

    254 pcs in stock

    $47.00
    $55.46 inclGST

  • Fastron Electronics Semiconductor Accessories Thermal Paste Pack, for 2 x Single or 1 x 3 Phase SSR FE-Thermal Paste Pack

    Thermal Paste Pack, for 2 x Single or 1 x 3 Phase SSR

    560 pcs in stock

    Small Thermal paste pack for 2 x Single or 1 x 3 Phase SSR

    560 pcs in stock

    $1.00
    $1.18 inclGST

  • Fastron Electronics LEM Accessories 92.43.07.461.0, DHAB Connector Kit FE-92.43.07.461.0

    92.43.08.445.0, DHAB Connector Kit

    48 pcs in stock

    92.43.08.445.0, DHAB Connector Kit to suit LEM DHAB Series Automotive Sensor Product Datasheet Product Drawings

    48 pcs in stock

    $11.90
    $14.04 inclGST

  • SCT-F36-250-5A, 5 Amp, 250Amp Measurement, Class 1 Split Core CT's SCT-F36-300-5A, 5 Amp, 300Amp measurement Split Core CT's-Split Core AC Current Transformer-Fastron Electronics-Fastron Electronics Store

    SCT-F36-250-5A, 5 Amp, 250Amp Measurement, Class 1 Split Core CT's

    63 pcs in stock

    Fastron Electronics SCT-F36-250-5A, 5 Amp, 250Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-250-5A Technology Split Core AC Current Transformer Ratio 250/5 Amp Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    63 pcs in stock

    $66.50
    $78.47 inclGST

  • SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's

    SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's

    11 pcs in stock

    Fastron Electronics SCT-F50-800-5A, 5 Amp, 800Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 5 Amp Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements   Specification Fastron Part Number SCT-F50-800-5A Technology Split Core AC Current Transformer Ratio 800/5 Amp Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9   Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's

    11 pcs in stock

    $110.55
    $130.45 inclGST

  • SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516 SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516

    SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516

    12 pcs in stock

    Eastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516 Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters. Can be used for any 100 Amp Direct Connect application  RS 485 communication up to 38,400 bit/s as standard Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) SAA Approved   The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.   Features : Accuracy Class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM230Modbus-MID-V2 (SLX) Functions Single Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 230V L-N 230V L-N, 100 Amp Maximum Measurement Range 276 L-N 230V L-N,100 Amp Nominal Current Input Direct connect 100 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s (100ms Response) Weight 250g Certification EN 61010-1 Installation Category III, SAA212516 Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C   Documents Product Datasheet User Manual Modbus Protocol Alternatives WM3-6 230DB Modbus Utility EEM Meter Setting Software Utility

    12 pcs in stock

    $184.00
    $217.12 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account