Crydom DRH3P60A20, 20 Amp AC Semiconductor Motor Controller & Contactor, 90-280VAC Control, 48-600VAC Load, 2 x NO aux contacts
Features
20 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRH3P60A20
Switching Type
Zero Crossing
Approvals
ROHS,CE,ULIEC
Control Voltage
90-280VAC
Transient Voltage
1200V
Load Current (per phase)
20 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-600VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra Doo MST-25-0.16, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-0.16
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
0.25 - 0.4 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Iskra Doo MST-25-0.25, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-0.25
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
0.25 - 0.4 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Iskra Doo MST-25-0.4, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-0.4
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
0.25 - 0.4 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Iskra Doo MST-25-0.63, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-0.63
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
0.4 - 0.63 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Iskra Doo MST-25-1, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Thermal release
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MST-25-1
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
0.63 - 1 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal Release Only
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series