Motor Control

129 products

  • Last stock! MST-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal Release Only

    1 pcs in stock

    Iskra Doo MST-25-1.6, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-1.6 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1 - 1.6 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    1 pcs in stock

    $69.00
    $81.42 inclGST

  • Last stock! MST-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-2.5, Motor Protection Switch, 3 Phase, 690VAC, 1.6 - 2.5 Amp Setting Range, Thermal Release Only

    1 pcs in stock

    Iskra Doo MST-25-2.5, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-2.5 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1.6 - 2.5 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    1 pcs in stock

    $69.00
    $81.42 inclGST

  • MS-25-0.16, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-0.16, Motor Protection Switch, 3 Phase, 690VAC, 0 - 0.16 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Iskra Doo MS-25-0.16, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0 - 0.16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    $72.00
    $84.96 inclGST

  • MS-25-0.25, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-0.25, Motor Protection Switch, 3 Phase, 690VAC, 0.16 - 0.25 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Iskra Doo MS-25-0.25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.16 - 0.25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    $72.00
    $84.96 inclGST

  • MS-25-0.4, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-0.4, Motor Protection Switch, 3 Phase, 690VAC, 0.25 - 0.4 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Iskra Doo MS-25-0.4, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.4 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.25 - 0.4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series 

    Out of stock

    $72.00
    $84.96 inclGST

  • MS-25-0.63, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-0.63, Motor Protection Switch, 3 Phase, 690VAC, 0.4 - 0.63 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Iskra Doo MS-25-0.63, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-0.63 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 0.4 - 0.63 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    $72.00
    $84.96 inclGST

  • Last stock! MS-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-1.6, Motor Protection Switch, 3 Phase, 690VAC, 1 - 1.6 Amp Setting Range, Thermal and Magnetic Release

    1 pcs in stock

    Iskra Doo MS-25-1.6, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-1.6 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 1 - 1.6 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    1 pcs in stock

    $72.00
    $84.96 inclGST

  • MS-25-4, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-4, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    20 pcs in stock

    Iskra Doo MS-25-4, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-4 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.3 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series 

    20 pcs in stock

    $72.00
    $84.96 inclGST

  • MST-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MST-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal Release Only

    Out of stock

    Iskra Doo MST-25-6.3, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-6.3 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    $69.00
    $81.42 inclGST

  • MST-25-25, Motor Protection Switch, 3 Phase, 690VAC, 20 - 25 Amp Setting Range, Thermal Release only Iskra Doo Motor Protection Switch MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range FE-MS-25-20

    MST-25-25, Motor Protection Switch, 3 Phase, 690VAC, 20 - 25 Amp Setting Range, Thermal Release only

    Out of stock

    Iskra Doo MST-25-25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 20 - 25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series 

    Out of stock

    $79.00
    $93.22 inclGST

  • Last stock! MS-25-25, Motor Protection Switch, 3 Phase, 690VAC, 20 - 25 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range FE-MS-25-20

    MS-25-25, Motor Protection Switch, 3 Phase, 690VAC, 20 - 25 Amp Setting Range, Thermal and Magnetic Release

    2 pcs in stock

    Iskra Doo MS-25-25, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-25 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 20 - 25 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    2 pcs in stock

    $76.00
    $89.68 inclGST

  • GHM9C1-0600-001, Optical Incremental Encoder  with overspeed switch GHM9C1-0600-001, Optical Incremental Encoder  with overspeed switch

    GHM9C1-0600-001, Optical Incremental Encoder with overspeed switch

    Out of stock

    Sensata (BEI Sensors) Optical Incremental Encoder with Overspeed Switch ø12mm x 30mm 240VAC Supply Centrifugal Uoutput:A,A/B,B/0,0/(0, A&B Gated) Resolution:600 rpm Connection:M23 12 Broches CCW Radial 7M cable Model GHM9_C1//5G59//00600//G6R//**07** Specification Sensata (BEI Sensors) Part Number GHM9C1-0600-001 Principal Centrifugal Mechanical Life 500000 Cycles Special Feature Overspeed Max Breaking Sequence Dual with Index Supply 6A/240VAC Protection Class IP65 (Mounted) Contact Type Open or Closed Output Termination 4 pinout solenoid valve connector Unit Weight 1.1kg Factory Pack Qty 1   Datasheet Product Datasheet Selection Guide Selection Guide

    Out of stock

    $1,649.00
    $1,945.82 inclGST