Sensata (BEI Sensors) DHO5S Atex Incremental Encoder
IP65 - Designed for explosive Dust and Gas environments
IEC certification for Zone 2 T4 (Ex ‘d' or Ex‘e‘or Ex‘n’)
High Resolution available up to 80000 cpt
Universal Electronic Circuit from 5 to 30VDC
High Performance in temperature - 30°C to 70 °C
High Performances in frequency up to 300kHz
Specification
Sensata (BEI Sensors) Part Number
DHO5S10/E2/PG59//01024//G3R100//D0DD**
Shaft ø
10mm
Supply Voltage
5 to 30VDC
Output Stage
Push-Pull
Output Signals
A,A/,B,B/,0,0/(0 gated A & B)
Resolution
1024 cpt
Revolutions
2000rpm
Connection
10M PVC Cable 8 wires
Shaft Style
Hollow
Unit Weight
Factory Pack Qty
1
Datasheet
Product Datasheet
Selection Guide
Selection Guide
Sensata (BEI Sensors) DHO5S Atex Incremental Encoder
IP65 - Designed for explosive Dust and Gas environments
IEC certification for Zone 2 T4 (Ex ‘d' or Ex‘e‘or Ex‘n’)
High Resolution available up to 80000 cpt
Universal Electronic Circuit from 5 to 30VDC
High Performance in temperature - 30°C to 70 °C
High Performances in frequency up to 300kHz
Specification
Sensata (BEI Sensors) Part Number
DHO5S10/E2/PG59//01024//G3R100//D0DD**
Shaft ø
10mm
Supply Voltage
5 to 30VDC
Output Stage
Push-Pull
Output Signals
A,A/,B,B/,0,0/(0 gated A & B)
Resolution
1024 cpt
Revolutions
2000rpm
Connection
2M PVC Cable 8 wires
Shaft Style
Hollow
Unit Weight
Factory Pack Qty
1
Datasheet
Product Datasheet
Selection Guide
Selection Guide
Sensata (BEI Sensors) H25D-SS-12NB-S1-CW-ECS18, Optical Incremental Encoder Heavy Duty 25" Diameter, Shaft Seal, 12 Cycles/Turn
The H25 is the flagship of the BEI Sensors product line. It was designed from the ground up for the industrial marketplace. The H25 offers features such as EMI shielding, 40 lb. ABEC 7 bearings, matched thermal coefficients on critical components, and custom high efficiency optics. The encoder meets NEMA 4 and 13 requirements when ordered with the shaft seal. Typical applications include machine control, process control, the wood processing industry, oil well logging, industrial weighing, agricultural machinery, textile equipment, web process control, robotics, and food processing.
Special Models of the H25 Incremental Encoder are available with one or more of the following certifications. Consult factory for details.
Specification
Sensata (BEI Sensors) Part Number
H25D-SS-12NB-S1-CW-ECS18 (01079-222)
Housing
Square Flange
Shaft Seal Config
Shaft Seal
Cycle Per Turn
12
No. of Channels
Dual with Index
Complements
Complimentary Outputs
Encoder Type
Incremental Optical
Voltage Output
Termination Location
End
Output Termination
Pigtail 18" long
Unit Weight
Factory Pack Qty
1
Datasheet
Product Datasheet
Selection Guide
Selection Guide
Gigavac GV141MAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12/24VDC PWM Coil
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Giagavac Part Number
GV141MAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
12/24VAC/DC
Load Current
400+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
PWM Rated Coil
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 100VDC
Standards
CE, UL1604, IP67, SAEJ1171
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Iskra Doo MS-25-10, 3 Phase Motor Protection Switch
Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc.
Features :
Magnetic and Thermal releases
< 50mS Trip Delay Time
3 Pole Disconnect
Short Circuit Breaking Capacity up to 4kA
Voltage resettable version available
Customised versions available
Standards :
IEC/EN 60898,60947-3
IP20 (IP40 Installed) IEC 61008
AS/NZ 61009-1
Specification
Iskra Doo Part Number
MS-25-10
Functions
3 Phase Motor Protection Switch
Nominal Voltage
230/400VAC @ 50/60Hz
Nominal Current Range
6 - 10 Amp RMS
Trip Delay Time
< 50ms
Rated Frequency
50/60 Hz
Operating Temperature
-25 to 60 Deg C
Rated Operations
100,000 Ops
Insulation Voltage
690V
Overload Protection
Thermal and Magnetic Release
Breaking Capacity
230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA)
Approvals
CSA, EAC
Standards
IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1
Weight
230g
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
Alternatives
Trent FGV2 Series
Crydom DRC3P48D420R Series AC Motor Controller & Solid State Contactor
Features
7.6 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRC3R48D420
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
18-30VAC/DC
Load Current
7.6 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Auxiliary Contacts
2 x NO 1 Amp Solid State
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DRC3 Series AC Motor Controller & Solid State Contactor
Features
7.6 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRC3R48D420
Switching Type
Zero Crossing
Approvals
ROHS,UL,CE,IEC
Control Voltage
208-265VAC
Load Current
7.6 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Auxiliary Contacts
2 x NO 1 Amp Solid State
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom DRC3R48D420, AC Motor Controller & Contactor, 7.6 Amp, 48VAC/DC control, 48-530VAC Load, 2 Solid State NO Aux Contacts, Zero Crossing
Features
7.6 Amp AC Semiconductor Motor Controller
Load voltage range up to 600VAC
Fits standard 35mm DIN Rail
LED input status indicator
AC or DC control
Zero Voltage (resistive loads) or instantaneous (inductive loads) turn-on output
C-UL-US Listed, CCC Certified, IEC Rated, CE & RoHS Compliant, Horsepower Rated
Built-in Overvoltage Protection
Ultra-efficient thermal management design (Patented)
Spec
Crydom Part Number
DRC3R48D420
Switching Type
DC Load
Approvals
ROHS,UL,CE,IEC
Control Voltage
48VAC/DC
Load Current
7.6 Amp (rms)
Surge Capability (10ms)
716 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
DIN Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
197g
Factory Pack Qty
20
Datasheet
Product Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies