Motor Control

129 products

  • MST-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range FE-MS-25-20

    MST-25-20, Motor Protection Switch, 3 Phase, 690VAC, 16 - 20 Amp Setting Range, Thermal Release Only

    8 pcs in stock

    Iskra Doo MST-25-20, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 16 - 20 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    8 pcs in stock

    $89.75
    $105.91 inclGST

  • MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Iskra Doo Motor Protection Switch MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range FE-MS-25-6.3

    MS-25-6.3, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    19 pcs in stock

    Iskra Doo MS-25-6.3, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-6.3 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    19 pcs in stock

    $75.00
    $88.50 inclGST

  • MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal and Magnetic Release MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range - Fastron Electronics Store

    MS-25-16, Motor Protection Switch, 3 Phase, 690VAC, 10 - 16 Amp Setting Range, Thermal and Magnetic Release

    Out of stock

    Iskra Doo MS-25-16, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-16 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 10 - 16 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    Out of stock

    $77.00
    $90.86 inclGST

  • 84874320 Crouzet C-Lynx Speed Monitoring/Control Relay With SPDT Contacts, 24 - 240 V AC/DC

    84874320 Crouzet C-Lynx Speed Monitoring/Control Relay With SPDT Contacts, 24 - 240 V AC/DC

    16 pcs in stock

    84874320 Crouzet C-Lynx Speed Monitoring/Control Relay With SPDT Contacts, 24 - 240 V AC/DC Pick up this Crouzet HSV Control/Speed Monitoring Relay from the team at Fastron Electronics. Capable of controlling overspeed, operating rate, underspeed, and stopping, this is an industry-leading speed monitoring relay component. Compatible with either NC or NO sensors, this monitoring/control relay also features adjustable energy monitoring capabilities. For more information about this product, explore the description, specification and datasheet on this page. Alternatively, the Fastron Electronics team is always happy to assist you with all your technical support requirements. With more than 40 years of experience in energy monitoring and energy management, we are proud to offer the highest quality products, with free shipping available on all purchases over $300AUD. Looking for an alternative product? Contact Fastron Electronics today to enquire about availability and pricing information. We would be more than happy to help you with your custom project. Crouzet HSV Speed Monitoring/Control Relay With SP-NO/NC Contacts DIN Rail Mount 35 mm HSV Part number 84874320 : Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type Works with either NO or NC sensors Time between pulses adjustable from 0.05 s to 10 min. Power-on inhibit time, adjustable from 0.6 to 60 s Inhibit time can be managed via an external contact   Specification Crouzet Part Number 84874320 (Single Phase C-Lynx Speed Monitoring Relay With SPDT Contacts) Function Speed Control Nominal Voltage 24 → 240 V AC/DC Frequency of Measured Signal 1.5 m Hz minimum, 22 Hz maximum Measurement Ranges 0,5 s - 1 s - 5 s - 10 s - 1 mn - 5 mn - 10 mn Digital Output 1 x C/O Relays, 250VAC/DC @ 5 Amp Min Breaking Current 10mA/5VDC Inhibit Delay Timing Range 0.6 → 60s (0, +10% of full scale) Delay on Pickup 50ms Threshold Crossing Response 15ms Reset Time (Memory Mode) 50ms Reset Time (Power Break) 1500ms Isolation 4kV Repetition Accuracy 0.5% Threshold Adjustment Range 10 → 100 % of the range Termination Style Screw Weight 170g Certification UL, CSA, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22   Datasheet Product Datasheet

    16 pcs in stock

    $359.00
    $423.62 inclGST

  • PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage

    9 pcs in stock

    Iskra Doo PS11, Auxiliary Contact for MS and MST Series Motor Protection Switch, 230VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number PS11 Functions Auxiliary Contact for 3 Phase Motor Protection Switch, 1 x NO 6 Amp @ 230VAC, 1 x NC 6 Amp @ 230VAC Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @230VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    9 pcs in stock

    $18.00
    $21.24 inclGST

  • FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 18 Amp Setting Range, Thermal and Magnetic Release

    56 pcs in stock

    Trent FGV2-M20, Motor Protection Switch, 3 Phase, 690VAC, 13 - 28 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M20 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 13 - 18 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    56 pcs in stock

    $68.00
    $80.24 inclGST

  • FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M08, Motor Protection Switch, 3 Phase, 690VAC, 2.3 - 4 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M08 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 2.3 - 4 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release

    59 pcs in stock

    Trent FGV2-M10, Motor Protection Switch, 3 Phase, 690VAC, 4 - 6.3 Amp Setting Range, Thermal and Magnetic Release Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Trent Part Number FGV2-M10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 4 - 6.3 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives  

    59 pcs in stock

    $62.00
    $73.16 inclGST

  • Last stock! 11.216.995 AMJ5883 MAHLE (AMJ5239) MAHLE - Letrika Unidirectional Clockwise 24VDC Motor, 2.2kW, 2600rpm 11.216.995 AMJ5883 MAHLE (AMJ5239) MAHLE - Letrika Unidirectional Clockwise 24VDC Motor, 2.2kW, 2600rpm-DC Motor-MAHLE-Fastron Electronics Store

    11.216.995 AMJ5883 MAHLE (AMJ5239) MAHLE - Letrika Unidirectional Clockwise 24VDC Motor, 2.2kW, 2600rpm

    1 pcs in stock

    ISKRA LETRIKA (MAHLE) 11.216.995 AMJ5883 (AMJ5239) Clockwise 24VDC Motor, 2.2kW, 2600rpm Used in BROC (OIL SISTEM) MAHLE Part # MM 62 ISKRA 11216995 11216.995 IM0126 Specification Product Motor Letrika P/N IM0029 Voltage 24 V Power 2.2 kW OEM P/N 11.216.995 MAHLE P/N MM 62 Description AMJ5883 No. of revolutions 2,600/min Rotation ⇒ S1 S2 1.2 min S3 4.5 %ED Mass 6.9 kg Flange Customer design Termo protection No Ventilation No Notes Hydraulics Insulated ground Datasheet Product Datasheet Cross Reference Manufacturer Manufacturer P/N BROC (OIL SISTEM) c162 011 000 BROC (OIL SISTEM) c162 091 000 BROC (OIL SISTEM) c162 0S1 046 GEORGI KOSTOV EC 1.5/2.4/27 GEORGI KOSTOV EC 2/2.4/23-02 Letrika P/N OEM P/N MAHLE P/N IM0029 11.216.995 AMJ5883 24V 2,2kW MM 62 Available IM0029 11.216.541 AMJ5781 24V 2,2kW Superseded unit, see available P/N IM0029 IM0029 11.212.865 AMJ5239 24V 2,2kW MM 380 Superseded unit, see available P/N IM0029 IM0029 11.212.612 AMJ5178 24V 2,2kW Superseded unit, see available P/N IM0029 IM0029 11.212.088 AMJ5652 24V 2,0kW MM 376 Superseded unit, see available P/N IM0029 IM0029 11.212.070 AMJ5636 24V 2,0kW Superseded unit, see available P/N IM0029 Spare Parts Pos. Letrika P/N MAHLE P/N Description 1 16.283.549 MMX 652 Drive end bracket 2 16.905.263 MMX 892 Bearing 4 16.908.144 MMX 191 Armature 5 16.908.630 MMX 232 Bearing 7 16.906.356 MMX 263 Bolt 8 16.287.010 Stator 10 16.906.472 MMX 688 Brush holder 11 16.908.051 MMX 893 Set of brushes 13 16.283.126 MMX 526 Rear-end bracket

    1 pcs in stock

    $1,018.69
    $1,202.05 inclGST

  • MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only Iskra Doo Motor Protection Switch MS-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range FE-MS-25-10

    MST-25-10, Motor Protection Switch, 3 Phase, 690VAC, 6 - 10 Amp Setting Range, Thermal Release Only

    10 pcs in stock

    Iskra Doo MST-25-10, 3 Phase Motor Protection Switch Motor Protection Circuit Breakers anre a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Thermal release < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MST-25-10 Functions 3 Phase Motor Protection Switch Nominal Voltage 230/400VAC @ 50/60Hz Nominal Current Range 6 - 10 Amp RMS Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal Release Only Breaking Capacity 230V(6kA) 415V(4kA) 500V(2.5kA) 690V(2kA) Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 230g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet Alternatives Trent FGV2 Series   

    10 pcs in stock

    $89.75
    $105.91 inclGST

  • Last stock! 11.216.796 AME1126 MAHLE DC Motor, 24VDC 0.8kW, 4500rpm 11.216.796 AME1126 MAHLE DC Motor, 24VDC 0.8kW, 4500rpm

    11.216.796 AME1126 MAHLE DC Motor, 24VDC 0.8kW, 4500rpm

    1 pcs in stock

    ISKRA LETRIKA (MAHLE) 11.216.796 AME1126 DC Motor, 24VDC 0.8kW, 4500rpm   MAHLE 11216796 ISKRA IM0315, 11216855, AME1598, 11216796, AME1126, MM334, 11216182, AME1598 Specification ISKRA (MAHLE) Part Number 11.216.796 AME1126 ISKRA/LETRIKA IM0315, 11216855, AME1598, 11216796, AME1126, MM334, 11216182, AME1598 MAHLE 11216796 Voltage 24VDC Power 0.8kW Rotation Unidirectional, Counter Clockwise Rotation Speed 4500 rpm Oil System c1620S1029 Unit Weight 3.00kg Factory Pack Qty 1   Cross Reference BROC (OIL SISTEM) c1620S1029 JUNGHEINRICH 50305489 MAHLE LETRIKA (ISKRA) IM0315, 11216855, AME1598, 11216796, AME1126, MM334, 11216182, AME1598  

    1 pcs in stock

    $669.00
    $789.42 inclGST

  • Last stock! MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage

    5 pcs in stock

    Iskra Doo MS-25-A220-240, Shunt Trip Release for MS and MST Series Motor Protection Switch, 220-240VAC Nominal Voltage Motor Protection Circuit Breakers are a special type of circuit breaker designed for protection of a wide range of single and 3 phase AC motors against overload and Short circuit. Used in industry, small machines, agricultural machines, compressors etc. Features : Magnetic and Thermal releases < 50mS Trip Delay Time 3 Pole Disconnect Short Circuit Breaking Capacity up to 4kA Voltage resettable version available Customised versions available Standards : IEC/EN 60898,60947-3 IP20 (IP40 Installed) IEC 61008 AS/NZ 61009-1 Specification Iskra Doo Part Number MS-25-A220-240 Functions Shunt Trip release for 3 Phase Motor Protection Switch Nominal Voltage 230VAC @ 50/60Hz Nominal Current Range 6 Amp RMS @400VAC Trip Delay Time < 50ms Rated Frequency 50/60 Hz Operating Temperature -25 to 60 Deg C Rated Operations 100,000 Ops Insulation Voltage 690V Overload Protection Thermal and Magnetic Release Breaking Capacity N/A Approvals CSA, EAC Standards IEC/EN 60947-2/4-1/5-1, IP20 (IP40 Installed) IEC 61008 ; AS/NZ 61009-1 Weight 100g Enclosure Material UL94 Factory Pack Qty 1   Datasheet Product Datasheet

    5 pcs in stock

    $39.80
    $46.96 inclGST

Login

Forgot your password?

Don't have an account yet?