LEM Products

823 products

  • DHAB S/124, O/L Automotive AC/DC Current Transducer, Multirange +/-75A +/-500A, 5VDC Supply, 22.5mm Round Aperture

    DHAB S/124, O/L Automotive AC/DC Current Transducer, Multirange +/-75A +/-500A, 5VDC Supply, 22.5mm Round Aperture

    1 review

    197 pcs in stock

    LEM DHAB S/124, O/L Automotive AC/DC Current Transducer, Multirange +/-25A +/-500A, 5VDC Supply, 22.5mm Round Aperture Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-25A, and +/-500A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/124 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-75 Amp Load Current Channel 2 (RMS) +/-500 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC - 70Hz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.7%(37A),1.3%(75A) CH2 Accuracy @ 25 Deg C 1%(0A),6%(250A),9%(500A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet

    197 pcs in stock

    $75.00
    $88.50 inclGST

  • DHAB S/134, Automotive Hall Effect Sensor, Dual Range, CH1: +/-50A CH2: +/-200A, Cable or Panel Mount, 22.5mm round aperture

    DHAB S/134, Automotive Hall Effect Sensor, Dual Range, CH1: +/-50A CH2: +/-200A, Cable or Panel Mount, 22.5mm round aperture

    94 pcs in stock

    LEM DHAB S/134 Series O/L Automotive AC/DC Current Transducer, Multirange Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-50A, and +/-200A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/134 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-50 Amp Load Current Channel 2 (RMS) +/-200 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 1.1kHz Mounting Style Panel Mount/Cable Mount Aperture ?22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.7%(37A),1.3%(75A) Ch2 Accuracy @ 25 Deg C 1.4%(0A),7%(375A),10%(750A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet

    94 pcs in stock

    $75.00
    $88.50 inclGST

  • DHAB S/133, Automotive Hall Effect Sensor, Dual Range, CH1: +/-75A CH2: +/-750A, Cable or Panel Mount, 22.5mm round aperture

    DHAB S/133, Automotive Hall Effect Sensor, Dual Range, CH1: +/-75A CH2: +/-750A, Cable or Panel Mount, 22.5mm round aperture

    174 pcs in stock

    LEM DHAB S/133 Series O/L Automotive AC/DC Current Transducer, Multirange Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-75A, and +/-750A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/133 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-75 Amp Load Current Channel 2 (RMS) +/-750 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 1.1kHz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.7%(37A),1.3%(75A) Ch2 Accuracy @ 25 Deg C 1.4%(0A),7%(375A),10%(750A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet

    174 pcs in stock

    $75.00
    $88.50 inclGST

  • DHAB S/118, O/L Automotive AC/DC Current Transducer, Multirange +/-30A +/-350A, 5VDC Supply, 22.5mm Round Aperture

    DHAB S/118, O/L Automotive AC/DC Current Transducer, Multirange +/-30A +/-350A, 5VDC Supply, 22.5mm Round Aperture

    213 pcs in stock

    LEM DHAB S/118 Series O/L Automotive AC/DC Current Transducer, Multirange Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/118 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-30 Amp Load Current Channel 2 (RMS) +/-350 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 1.1kHz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 0.15%(0A),0.45%(20A),0.7%(30A) CH2 Accuracy @ 25 Deg C 1%(0A),3.5%(175A),5%(350A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet

    213 pcs in stock

    $75.00
    $88.50 inclGST

  • LEM International SA AC/DC Current Hall Effect Sensor Automotive CAB 300-C/SP3-000, Fluxgate Automotive Battery Sensor, +/-350Amp Measurement, 12VDC Supply, 24.2mm ø Aperture, Accuracy = 0.5%, Unlimited Overcurrent Capability, Cable Mount, Can Bus ID 0x3C0 FE-CAB 300-C/SP3-000

    CAB 500-C/SP5, Fluxgate Automotive Battery Sensor, +/-500Amp Measurement, 12VDC Supply, 24.2mm ø Aperture, Accuracy = 0.5%, Unlimited Overcurrent Capability, Cable Mount, Programmable Can Bus ID

    240 pcs in stock

    LEM CAB 500-C/SP5, Fluxgate Automotive Battery Sensor, +/-500Amp Measurement, 12VDC Supply, 24.2mm ø Aperture, Accuracy = 0.5%, Unlimited Overcurrent Capability, Cable Mount, Programmable Can Bus ID Features Transducer using Fluxgate technology +/-530Amp Measurement 12VDC Supply Accuracy = 0.5% Wide Temperature Range -40 to 105°C Unlimited Overcurrent Capability Panel Mount CAN Bus ID (Programmable) Nanocrystalline Magnetic Core Advantages No Offset Error High Accuracy Low Linearity Error Full Galvanic Seperation Austomotive Applications Hybrid and Electric Vehicle Battery Packs Conventional Lead Acid Batteries Accurate measurement for battery management applications Specification LEM Part Number CAB 500-C/SP5 Technology DC Hall Effect Protection Class See Datasheet Supply Voltage 8 - 16VDC Load Current (RMS) -530 to 530 Amp Output CAN.C Bus (500kbps) ver 2.0A/B CAN Bus ID Programmable Electrostatic Discharge Voltage 4kV at pinout Isolation 2.5kV (50Hz, 1min) Aperture ø 24.2mm Mounting Style Panel Mount Operating Temperature Range -40 to 105°C Accuracy 0.5% Termination Style Tyco=AMP P/N:1 473672-1 Unit Weight 67g Factory Pack Qty 1   Datasheet Product Datasheet

    240 pcs in stock

    $145.00
    $171.10 inclGST

  • ATO 5 B420 D10/SP4, AC CT, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%-AC Current Transformer with Process Output-LEM International SA-Fastron Electronics Store

    ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%

    19 pcs in stock

    LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5% Features 125 Amp AC Current Measurement Signal Conditioned output Split Core 4-20mA Current Output Cable or Din Rail Mounting 20-28VDC Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number ATO-5-B420-D10-SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage 20-30VDC Loop Powered (10mA) Load Current (RMS) 125 Amp Output 4-20mA (Average RMS) Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -10°C / 55°C Accuracy 1.5% Termination Style 4M Output Cable Unit Weight 140g Factory Pack Qty 6   Datasheet Product Datasheet  

    19 pcs in stock

    $181.50
    $214.17 inclGST

  • DHAB S/137, Automotive Hall Effect Sensor, Dual Measurement Range, CH1: +/-75A CH2: +/-1000A, Cable or Panel Mount, 22.5mm round aperture

    DHAB S/137, Automotive Hall Effect Sensor, Dual Measurement Range, CH1: +/-75A CH2: +/-1000A, Cable or Panel Mount, 22.5mm round aperture

    185 pcs in stock

    LEM DHAB S/137 Series O/L Automotive AC/DC Current Transducer, Multirange Features Open Loop Transducer using Hall Effect Low Voltage Application Unipolar +5V Power Supply Primary Current Measuring Range up to +/-75A, and +/-1000A for Channel 2 Maximum RMS primary admissable current: defined by busbar to have T° < +150°C Operating Temperature Range: -40°C < T° < +125°C Output Voltage: Full ratio-metric (in sensitivity and offset) Dual Channel Sensor for Wider Measurement Range and Redundancy Advantages Good Accuracy for High and Low Current Range Good Linearity Low Thermal Offset Drift Low Thermal Sensitivity Drift Hermetic Package Automotive Applications Battery Pack Monitoring Hybrid Vehicles EV and Utility Vehicles Specification LEM Part Number DHAB S/137 Technology Multirange Open Loop Hall Effect ROHS Yes Supply Voltage 5 VDC Load Current Channel 1 (RMS) +/-75 Amp Load Current Channel 2 (RMS) +/-1000 Amp Output 0.25 - 4.75V (2.5Vref) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth(-3dB) DC - 70Hz Mounting Style Panel Mount/Cable Mount Aperture ⌀22.5mm Operating Temperature Range -40°C - 70°C CH1 Accuracy @ 25 Deg C 15%(0A),0.7%(25A),1.3%(75A) CH2 Accuracy @ 25 Deg C 3%(0A),9%(500A),15%(900A),20%(1000A) Termination Style TYCO 1-1456426-5 Unit Weight 100g Factory Pack Qty 6 Datasheet Product Datasheet

    185 pcs in stock

    $75.00
    $88.50 inclGST

  • LEM International SA Split Core AC Current Transformer with Process Output ATO-5-B420-D10-SP4, AC CT, 20-30VDC loop powered, 5 Amp Average RMS 4-20mA output, X = 1.5% FE-ATO-5-B420-D10-SP4

    TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1%

    139 pcs in stock

    LEM TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1% Features 90 Amp AC Current Measurement Signal Conditioned output Split Core 0-90mA Instantaneous Cable or Din Rail Mounting Self Powered Isolated plastic case recognised according to UL94-V0 UL508 Rated Advantages Large aperture for cable up to ? 10mm High isolation between primary and secondary circuits Easy installation Applications Hybrid Inverter UPS Power Metering Power Quality Analysis Distributed Measurement Systems Current Measurement Energy Management Motor Control Condition Monitoring Specification LEM Part Number TOP 90-S10/SP4 Technology AC Current Transformer Protection Class IP50 Supply Voltage Self Powered Load Current (RMS) 125 Amp Output 0-90mA rms Isolation 4.3kV (AC, 50Hz, 1 min) Bandwidth 50 - 60Hz Mounting Style Din Rail Mount or Cable Mount Operating Temperature Range -25°C / 70°C (for 100°C Conductors) Accuracy 1.5% Termination Style 1M Output Cable Unit Weight 150g Factory Pack Qty 6   Datasheet Product Datasheet Alterantive Fastron OEM Alternative

    139 pcs in stock

    $82.60
    $97.47 inclGST

  • DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip

    49 pcs in stock

    LEM DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip Features Bandwidth DC to 35kHz 8 Pins +/-15..24VDC Unipolar Supply 4-20mA Unipolar Output Closed loop transducer using Hall Effect Compact and versatile Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications AC variable speed drives and servo motor drives Single and Three Phase Inverters Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVC 1000-UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24VDC Primary Nominal Voltage +/-1000V Measurement Range +/-1500V Output 4-20mA Unipolar Instantaneous (0.5mA underange/21mA overrange) Isolation 4.2 kV Bandwidth DC-35 kHz Mounting Style Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0) Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Through Hole PCB Unit Weight 22g Factory Pack Quantity 25   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    49 pcs in stock

    $304.80
    $359.66 inclGST

  • LT 505-S, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +/-15...24VDC, X = 0.6%

    LT 505-S, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +/-15...24VDC, X = 0.6%

    23 pcs in stock

    LEM LT 505-S, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +/-15...24VDC, X = 0.6% Features Bipolar and insulated current measurement up tp 1200 Amp Current output Bandwidth DC to 150kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 505-S Technology Closed Loop Hall Effect Aperture ø40.5mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 500 Amp Measurement Range +/- 1200 Amp Output 100 mA Isolation 6 kV Bandwidth DC-150 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 0.6% Termination Style faston 6.3 x 0.8mm Unit Weight 400g Factory Pack Quantity 4   Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition  

    23 pcs in stock

    $605.00
    $713.90 inclGST

  • FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation

    FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation

    32 pcs in stock

    Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation Features Average RMS Output Split Core 4-20mA Current Output Cable Mounting 24VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Motor Control Actuators Lamp Failure Specification LEM Part Number AT 5 B420L Technology AC Current Transformer Protection Class IP50 Supply Voltage 24VDC Loop Powered (10mA) Load Current (RMS) 5 Amp Maximum Measurement Current (RMS) 6 Amp Output 4-20mA (Average RMS) Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth 50 - 400Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy 0.5% Aperture 16mm Termination Style Screw Approvals CE,UL,ROHS Unit Weight 140g Factory Pack Qty 6   Datasheet Product Datasheet  

    32 pcs in stock

    $82.00
    $96.76 inclGST

  • Last stock! HTA 400-S, O/L Hall Effect Current Sensor, 400 Amp, +/-4V Output

    HTA 400-S, O/L Hall Effect Current Sensor, 400 Amp, +/-4V Output

    4 pcs in stock

    LEM HTA 400-S Series Open Loop AC/DC Hall Effect Sensor Features Bandwidth DC to 50kHz Open loop transducer using Hall effect Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Wide dynamic range, 100 to 1000 A in one package. Applications AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number HTA 400-S Technology Open Loop Hall Effect Aperture ø32mm ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Load Current (RMS + DC) 400 Amp Measurement Range +/-1000 Amp Output +/-4 V Isolation 4 kV Bandwidth DC-50 kHz Mounting Style Panel Mount Operating Temperature Range -10°C / 80°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 230g Factory Pack Quantity 10 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    4 pcs in stock

    $138.50
    $163.43 inclGST

Login

Forgot your password?

Don't have an account yet?
Create account