LEM DHAB S/124, O/L Automotive AC/DC Current Transducer, Multirange +/-25A +/-500A, 5VDC Supply, 22.5mm Round Aperture
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-25A, and +/-500A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/124
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-75 Amp
Load Current Channel 2 (RMS)
+/-500 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC - 70Hz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.7%(37A),1.3%(75A)
CH2 Accuracy @ 25 Deg C
1%(0A),6%(250A),9%(500A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM DHAB S/134 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-50A, and +/-200A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/134
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-50 Amp
Load Current Channel 2 (RMS)
+/-200 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
?22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.7%(37A),1.3%(75A)
Ch2 Accuracy @ 25 Deg C
1.4%(0A),7%(375A),10%(750A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM DHAB S/133 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-75A, and +/-750A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/133
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-75 Amp
Load Current Channel 2 (RMS)
+/-750 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.7%(37A),1.3%(75A)
Ch2 Accuracy @ 25 Deg C
1.4%(0A),7%(375A),10%(750A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM DHAB S/118 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-30A, and +/-350A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/118
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-30 Amp
Load Current Channel 2 (RMS)
+/-350 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 1.1kHz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
0.15%(0A),0.45%(20A),0.7%(30A)
CH2 Accuracy @ 25 Deg C
1%(0A),3.5%(175A),5%(350A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM CAB 500-C/SP5, Fluxgate Automotive Battery Sensor, +/-500Amp Measurement, 12VDC Supply, 24.2mm ø Aperture, Accuracy = 0.5%, Unlimited Overcurrent Capability, Cable Mount, Programmable Can Bus ID
Features
Transducer using Fluxgate technology
+/-530Amp Measurement
12VDC Supply
Accuracy = 0.5%
Wide Temperature Range -40 to 105°C
Unlimited Overcurrent Capability
Panel Mount
CAN Bus ID (Programmable)
Nanocrystalline Magnetic Core
Advantages
No Offset Error
High Accuracy
Low Linearity Error
Full Galvanic Seperation
Austomotive Applications
Hybrid and Electric Vehicle Battery Packs
Conventional Lead Acid Batteries
Accurate measurement for battery management applications
Specification
LEM Part Number
CAB 500-C/SP5
Technology
DC Hall Effect
Protection Class
See Datasheet
Supply Voltage
8 - 16VDC
Load Current (RMS)
-530 to 530 Amp
Output
CAN.C Bus (500kbps) ver 2.0A/B
CAN Bus ID
Programmable
Electrostatic Discharge Voltage
4kV at pinout
Isolation
2.5kV (50Hz, 1min)
Aperture
ø 24.2mm
Mounting Style
Panel Mount
Operating Temperature Range
-40 to 105°C
Accuracy
0.5%
Termination Style
Tyco=AMP P/N:1 473672-1
Unit Weight
67g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM ATO 5 B420 D10/SP4, AC Current Transformer, 20-30VDC loop powered, 125 Amp Average RMS 4-20mA output, X = 1.5%
Features
125 Amp AC Current Measurement
Signal Conditioned output
Split Core
4-20mA Current Output
Cable or Din Rail Mounting
20-28VDC Powered
Isolated plastic case recognised according to UL94-V0
UL508 Rated
Advantages
Large aperture for cable up to ? 10mm
High isolation between primary and secondary circuits
Easy installation
Applications
Hybrid Inverter
Power Metering
Power Quality Analysis
Distributed Measurement Systems
Current Measurement
Energy Management
Motor Control
Condition Monitoring
Specification
LEM Part Number
ATO-5-B420-D10-SP4
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
125 Amp
Output
4-20mA (Average RMS)
Isolation
4.3kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount or Cable Mount
Operating Temperature Range
-10°C / 55°C
Accuracy
1.5%
Termination Style
4M Output Cable
Unit Weight
140g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM DHAB S/137 Series O/L Automotive AC/DC Current Transducer, Multirange
Features
Open Loop Transducer using Hall Effect
Low Voltage Application
Unipolar +5V Power Supply
Primary Current Measuring Range up to +/-75A, and +/-1000A for Channel 2
Maximum RMS primary admissable current: defined by busbar to have T° < +150°C
Operating Temperature Range: -40°C < T° < +125°C
Output Voltage: Full ratio-metric (in sensitivity and offset)
Dual Channel Sensor for Wider Measurement Range and Redundancy
Advantages
Good Accuracy for High and Low Current Range
Good Linearity
Low Thermal Offset Drift
Low Thermal Sensitivity Drift
Hermetic Package
Automotive Applications
Battery Pack Monitoring
Hybrid Vehicles
EV and Utility Vehicles
Specification
LEM Part Number
DHAB S/137
Technology
Multirange Open Loop Hall Effect
ROHS
Yes
Supply Voltage
5 VDC
Load Current Channel 1 (RMS)
+/-75 Amp
Load Current Channel 2 (RMS)
+/-1000 Amp
Output
0.25 - 4.75V (2.5Vref)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth(-3dB)
DC - 70Hz
Mounting Style
Panel Mount/Cable Mount
Aperture
⌀22.5mm
Operating Temperature Range
-40°C - 70°C
CH1 Accuracy @ 25 Deg C
15%(0A),0.7%(25A),1.3%(75A)
CH2 Accuracy @ 25 Deg C
3%(0A),9%(500A),15%(900A),20%(1000A)
Termination Style
TYCO 1-1456426-5
Unit Weight
100g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM TOP 90-S10/SP4, AC Current Transformer, 90 Amp 0-90mA rms output, X = 1%
Features
90 Amp AC Current Measurement
Signal Conditioned output
Split Core
0-90mA Instantaneous
Cable or Din Rail Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
UL508 Rated
Advantages
Large aperture for cable up to ? 10mm
High isolation between primary and secondary circuits
Easy installation
Applications
Hybrid Inverter
UPS
Power Metering
Power Quality Analysis
Distributed Measurement Systems
Current Measurement
Energy Management
Motor Control
Condition Monitoring
Specification
LEM Part Number
TOP 90-S10/SP4
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
125 Amp
Output
0-90mA rms
Isolation
4.3kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount or Cable Mount
Operating Temperature Range
-25°C / 70°C (for 100°C Conductors)
Accuracy
1.5%
Termination Style
1M Output Cable
Unit Weight
150g
Factory Pack Qty
6
Datasheet
Product Datasheet
Alterantive
Fastron OEM Alternative
LEM DVC 1000-UI, C/L DC Voltage Transducer, 1000V, +/-15..24VDC Supply, Unipolar 4-20mA Instantaneous Output, Panel Mount, or Din Rail Mount with Optional Clip
Features
Bandwidth DC to 35kHz
8 Pins
+/-15..24VDC Unipolar Supply
4-20mA Unipolar Output
Closed loop transducer using Hall Effect
Compact and versatile
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
AC variable speed drives and servo motor drives
Single and Three Phase Inverters
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVC 1000-UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
+/-15..24VDC
Primary Nominal Voltage
+/-1000V
Measurement Range
+/-1500V
Output
4-20mA Unipolar Instantaneous (0.5mA underange/21mA overrange)
Isolation
4.2 kV
Bandwidth
DC-35 kHz
Mounting Style
Panel Mount or Din Rail Mount with Optional Clip (93.30.R2.000.0)
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Through Hole PCB
Unit Weight
22g
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
LEM LT 505-S, C/L Hall Effect Current Sensor, 500 Amp, 100mA Output, +/-15...24VDC, X = 0.6%
Features
Bipolar and insulated current measurement up tp 1200 Amp
Current output
Bandwidth DC to 150kHz
Closed loop (compensated) current transducer
Panel mounting
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low offset drift over temperature
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Windmill Inverters
Test and Measurement
Substations
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Application Domain
Industrial
Standards
EN 50178:1997
IEC61010-1:2010
UL 508:2010
Specification
LEM Part Number
LT 505-S
Technology
Closed Loop Hall Effect
Aperture
ø40.5mm
ROHS
Yes
Supply Voltage
+/- 15 VDC to +/- 24 VDC Bipolar, Isolated
Load Current (RMS + DC)
500 Amp
Measurement Range
+/- 1200 Amp
Output
100 mA
Isolation
6 kV
Bandwidth
DC-150 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 85°C
Accuracy
0.6%
Termination Style
faston 6.3 x 0.8mm
Unit Weight
400g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron FCT-D16-5-420, AC Split Core Current Transducer, 16mm Aperture, 0-5 Amp Measurement, 4-20mA Average RMS output, 24VDC Loop Powered, Class 0.5, 50-400 Hz Operation
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
24VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
24VDC Loop Powered (10mA)
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
4-20mA (Average RMS)
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 400Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
0.5%
Aperture
16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
140g
Factory Pack Qty
6
Datasheet
Product Datasheet
LEM HTA 400-S Series Open Loop AC/DC Hall Effect Sensor
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 100 to 1000 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
HTA 400-S
Technology
Open Loop Hall Effect
Aperture
ø32mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
400 Amp
Measurement Range
+/-1000 Amp
Output
+/-4 V
Isolation
4 kV
Bandwidth
DC-50 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
230g
Factory Pack Quantity
10
Datasheet
Product Datasheet