Din Rail Mount Current, Voltage and Power Transducers

74 products

  • Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display

    Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display

    Out of stock

    Rishabh Rish Con M+ CM44111411, Class 0.5 Power Transducer 4 wire, 100-600V L-L, 1 or 5Amp measurement, 85-285VAC/DC Aux Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V Outputs, USB Programming Port, Modbus RTU Comms, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V (Programmable) Free Program Software 300mS response time PC 94 UL V0 Input Voltages, Current or Power Measurements can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con CM44111411 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable and Programable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 100 - 600VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-285VAC/DC Accuracy 0.2% Current, Voltage (0.5% Power) Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog Brand Comparison to Iskra UMT540 or MT540 Series  

    Out of stock

    $589.00
    $695.02 inclGST

  • GT-AV(0-150)-A-1, AC Voltage Transducer, 0-150V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output GT-AV(0-150)-A-1, AC Voltage Transducer, 0-150V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-150)-A-1, AC Voltage Transducer, 0-150V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-150)-D-1 Control Output 4-20mA Average RMS Input 0-150VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100 - 240V AC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • Rishabh Instruments AC Power Transducer Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D, Active Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 4-20mA output, with display FE-P 4WUB 100-500V 1/5A 60-300U 10 D Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485

    Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485

    Out of stock

    Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485 Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z Functions Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 57 - 500VAC 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC, or 24-60VAC/DC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog    

    Out of stock

    $379.00
    $447.22 inclGST

  • P43 221300M0, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    P43 221300M0, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    Out of stock

    Lumel P43 221300M0, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Lumel Part Number P43 221300M0 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 20 - 480VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-253VAC/90-320VDC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet 

    Out of stock

    $733.00
    $864.94 inclGST

  • GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV6-A-1 Control Output 4-20mA Average RMS Input 0-300VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-230)-A-1, AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output GT-AV(0-230)-A-1, AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-230)-A-1, AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-230)-A-1, AC Voltage Transducer, 0-230V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-230)-A-1 Control Output 4-20mA Average RMS Input 0-230VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-415)-A-1, AC Voltage Transducer, 0-415V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output GT-AV(0-415)-A-1, AC Voltage Transducer, 0-415V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-415)-A-1, AC Voltage Transducer, 0-415V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-415)-A-1, AC Voltage Transducer, 0-415V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-415-A-1 Control Output 4-20mA Average RMS Input 0-415VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-415)-D-4, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 0-10V Average RMS output GT-AV(0-415)-D-4, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 0-10V Average RMS output

    GT-AV(0-415)-D-4, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 0-10V Average RMS output

    6 pcs in stock

    Fastron Electronics GT-AV(0-415)-D-4, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 0-10V Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 0-10V DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-415)-D-1 Control Output 0-10V Average RMS Input 0-415VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    6 pcs in stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-150)-D-1, AC Voltage Transducer, 0-150V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-150)-D-1 Control Output 4-20mA Average RMS Input 0-150VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-500)-A-1, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-500)-A-1 Control Output 4-20mA Average RMS Input 0-500VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output

    GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output

    Out of stock

    Fastron Electronics GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-AV(0-500)-D-1 Control Output 4-20mA Average RMS Input 0-500VAC Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1   Datasheet Product Datasheet

    Out of stock

    $239.00
    $282.02 inclGST

  • APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability

    APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability

    9 pcs in stock

    LEM APR 50 B420L, Split Core AC Current Sensor, selectable 10, 25, 50 Amp, True RMS 4-20mA output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 10, 20, 50 Amp True RMS 4-20mA output Features Split Core True RMS output 4-20mA current output Busbar, or Din Rail Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 50 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Overload Infinite Output 4-20mA True RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    9 pcs in stock

    $324.47
    $382.87 inclGST

Login

Forgot your password?

Don't have an account yet?