Din Rail Mount Current, Voltage and Power Transducers

76 products

  • AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability

    Out of stock

    Free Aus Post Shipping for $300 Spend

    LEM AP 200 B10, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, Average RMS 10V/5V output, Infinite Overload Capability Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp Average RMS. Selectable 0-5V, 0-10V output Features Split Core Average RMS output 0-10V/0-5V voltage output Busbar, or Din Rail mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 18.5mm x 18.5mm High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AP 200 B10 Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC @ 30mA Nominal Current (RMS + DC) 100,150, 200 Amp Selectable Overload Infinite Output 0-10V/0-5V Average RMS Isolation 5kV (AC, 50Hz, 1 min) Bandwidth 30-2000Hz Mounting Style Din Rail mount or Busbar mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Spring Terminal Block (Female Included) Unit Weight 90g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $226.04
    $266.73 inclGST

  • Last stock! Northern Design Electronics Ltd Solid Core AC Current Transformer with Process Output XD-R420-2, Current Transducer, True RMS, Ipn = Selectable 5,10,15,20,25,30 Amp, 16-36VDC Loop powered FE-XD-R420-2

    XD-R420-2, Current Transducer, True RMS, Ipn = Selectable 5,10,15,20,25,30 Amp, 4-20mA out,16-36VDC Loop powered

    2 pcs in stock

    Northern Design XD-R420-2, Current Transducer, True RMS, Ipn = Selectable 5,10,15,20,25,30 Amp, 4-20mA out,16-36VDC Loop powered Features Ipn = Selectable 5,10,15,20,25,30 Amp True RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-R420-2 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable 5,10,15,20,25,30 Amp Output 4-20mA (True RMS) Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual Application Notes

    2 pcs in stock

    $209.00
    $246.62 inclGST

  • Last stock! Northern Design Electronics Ltd Solid Core AC Current Transformer with Process Output XD-P-2, Current Transducer, True RMS, Ipn = Selectable 7.5,15,22.5,30Amps, Pulse output, 16-36VDC Loop powered FE-XD-P-2

    XD-P-2, Current Transducer, True RMS, Ipn = Selectable 7.5,15,22.5,30Amps, Pulse output, 16-36VDC Loop powered

    2 pcs in stock

    Northern Design XD-P-2, Current Transducer, True RMS, Ipn = Selectable 7.5,15,22.5,30Amps, Pulse output, 16-36VDC Loop powered Features Ipn = Selectable Selectable 7.5,15,22.5,30Amps Average RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-P-2 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable Selectable 7.5,15,22.5,30Amps Output Pulse Output Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual

    2 pcs in stock

    $169.00
    $199.42 inclGST

  • Northern Design Electronics Ltd Solid Core AC Current Transformer with Process Output XD-I420-3, AC Current Transducer, Average RMS, Ipn = Selectable 50,100,150,200,300 Amp, 4-20mA out, 16-36VDC Loop powered FE-XD-I420-3

    XD-I420-3, AC Current Transducer, Average RMS, Ipn = Selectable 50,100,150,200,300 Amp, 4-20mA out, 16-36VDC Loop powered

    12 pcs in stock

    Northern Design XD-I420-3, AC Current Transducer, Average RMS, Ipn = Selectable 50,100,150,200,300 Amp, 4-20mA out, 16-36VDC Loop powered Features Ipn = Selectable 50,100,150,200,300 Amp Average RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-I420-3 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable 50,100,150,200,300 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual  

    12 pcs in stock

    $139.00
    $164.02 inclGST

  • Northern Design Electronics Ltd Solid Core AC Current Transformer with Process Output XD-I420-2, AC Current Transducer, Average RMS, Ipn = Selectable 15,30,45,60,75,100 Amp, 4-20mA out, 16-36VDC Loop powered FE-XD-I420-2

    XD-I420-2, AC Current Transducer, Average RMS, Ipn = Selectable 15,30,45,60,75,100 Amp, 4-20mA out, 16-36VDC Loop powered

    13 pcs in stock

    Northern Design XD-I420-2, AC Current Transducer, Average RMS, Ipn = Selectable 15,30,45,60,75,100 Amp, 4-20mA out, 16-36VDC Loop powered Features Ipn = Selectable 15,30,45,60,75,100 Amp Average RMS Output 4-20mA Current Output Din Rail Mounting 16-36VDC Loop Powered Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀ 16mm High isolation between primary and secondary circuits Easy installation Applications Current Measurement Energy Management Earth Leakage Measurement Motor Control Actuators Lamp Failure Specification Northern Design Part Number XD-I420-2 Technology AC Current Transformer Protection Class IP50 Supply Voltage 16-36VDC Loop Powered (10mA) Load Current (RMS) Selectable 15,30,45,60,75,100 Amp Output 4-20mA Isolation 4kV (AC, 50Hz, 1 min) Bandwidth 55 - 65Hz Mounting Style Din Rail Mount Operating Temperature Range -10°C / 65°C Accuracy Class 1 Termination Style Screw Unit Weight 180g Factory Pack Qty 6   Datasheet Product Brochure Product Manual  

    13 pcs in stock

    $179.00
    $211.22 inclGST

  • Last stock! Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    5 pcs in stock

    Rishabh Rish Con M-22132, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 4 x Analogue -20-20mA/4-20mA/-10-10V output, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting 0-20mA/4-20mA/0-10V 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con M-22132 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4 x 4-20mA/0-20mA/0-10V User Selectable Relay Output N/A Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 20 - 480VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-253VAC/90-320VDC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size 122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog  

    5 pcs in stock

    $529.00
    $624.22 inclGST

  • Last stock! Rish Con M-22122, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V output, 2 Relay Outputs, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Rish Con M-22122, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V output, 2 Relay Outputs, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    Rish Con M-22122, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V output, 2 Relay Outputs, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display

    2 pcs in stock

    Rishabh Rish Con M-22122, Class 0.5 Power Transducer 4 wire, 20-480V L-L, 5Amp measurement, 85-253VAC/90-320VDC Supply, 2 x Analogue -20-20mA/4-20mA/-10-10V output, 2 Relay Outputs, USB Programming Port, Modbus RTU Comms, 750 OHM Load Resistance, without display Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Analogue output setting -20-20mA/4-20mA/-10-10V 2 x Relay Outputs 0.5 Amp @ 250VAC 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 122.5 x 66 x 106.5mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con M-22121 Functions Active Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 2 x 4-20mA/0-20mA/0-10V User Selectable Minimum Load Resistance 750 Ohm Relay Output 2 x 0.5 Amp @ 250VAC NO Voltage Free Contacts Relay Type Voltage Free Contact, 0.5 Amp @ 250VAC Input 20 - 480VAC L-L 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -10 - 55°C Supply Voltage 85-253VAC/90-320VDC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Mounting Size  122.5 x 66 x 106.5mm Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Product User Manual Technical Support Rish Con P setup procedure blog  

    2 pcs in stock

    $529.00
    $624.22 inclGST

  • Last stock! UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    4 pcs in stock

    Iskra Doo UMT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms (U)MT version = Ring type terminal block Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.1 on Comms RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number UMT540-HSHFNAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 4 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations Ring Type Terminal Block Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software

    4 pcs in stock

    $2,099.50
    $2,477.41 inclGST

  • Last stock! Rishabh Instruments AC Voltage Transducer Rish Con-V-50-O1A1-O200-D-2,  AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display FE-Rish Con-V-50-O1A1-O200-D-2

    Rish Con V(500V)-50-H-O1A2-O2A2-Z-Z-Z, AC Voltage Transducer, 50Hz 65-500VAC Full Scale, Dual 0-20mA Output, 60-300VAC/DC Supply, without Display

    4 pcs in stock

    Rishabh Rish Con V(500V)-50-H-O1A2-O2A2-Z-Z-Z, AC Voltage Transducer, 50Hz 65-500VAC Full Scale, Dual 0-20mA Output, 60-300VAC/DC Supply, without Display Dual 0-20mA Output 250mS response time PC 94 UL V0 Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con V(500V)-50-H-O1A2-O2A2-Z-Z-Z Measurement Output Dual 0-20mA Input 65 - 500VAC 50/60Hz Overlaod (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC/DC Accuracy 0.2% Response Time 250mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog  

    4 pcs in stock

    $259.00
    $305.62 inclGST

  • MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms-AC Power Transducer-Iskra Doo-Fastron Electronics Store

    MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT550-SSHFNAASS (DIN), Multifunction Power Transducer, Class 0.1, 4 Wire, 50-500V L-N, 5A AC Input 16-400Hz, 70-300VDC or 80-276VAC Aux Input, 2 Programmable analogue outputs, 2 Pulse Outputs, USB, Ethernet, RS485 Comms Class 0.1 Active, Class 0.2 Reactive (EN 60688) RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT550-SSHFNAASS (DIN) Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 500V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.1(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $1,709.00
    $2,016.62 inclGST

  • Iskra Doo AC Power Transducer MT440 S S U S A A A R A, Multifunction Transducer, Class 0.5, 4 Wire, 500V 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 3 Programmable Analogue Outputs, 1 relay output, RS485 + USB Comms FE-MT440 S S U S A A A R A MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms

    MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms

    24 pcs in stock

    Iskra Doo MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output 4 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS485 2400-115200 b/s (RS232 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer

    24 pcs in stock

    $1,145.00
    $1,351.10 inclGST

  • MT406-1254, AC Voltage Transducer, Class 0.5, 110VAC (0-125V Scale) 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span Iskra Doo AC Voltage Transducer MT406-11, AC Voltage Transducer, Class 0.5, 500VAC 50/60Hz measurement, 57.7V Supply, 0-1mA output FE-MT406-11

    MT406-1254, AC Voltage Transducer, Class 0.5, 110VAC (0-125V Scale) 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span

    23 pcs in stock

    Iskra Doo MT406-1254 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-20mA analogue output for Moving Coil Voltmeter Average RMS values of voltage Features : Measurement of up to 125VAC Self powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-1254 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 110VAC (0-125V Scale) Maximum Measurement Range 132VAC Output 0-20mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software  

    23 pcs in stock

    $199.00
    $234.82 inclGST

  • MT406-34, AC Voltage Transducer, Class 0.5, 69.3VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span Iskra Doo AC Voltage Transducer MT406-11, AC Voltage Transducer, Class 0.5, 500VAC 50/60Hz measurement, 57.7V Supply, 0-1mA output FE-MT406-11

    MT406-34, AC Voltage Transducer, Class 0.5, 69.3VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT406-34 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-20mA analogue Output Average RMS values of voltage Features : Measurement of up to 76.2VAC Self Powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-34 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-69.3VAC Maximum Measurement Range 0-76.2VAC Output 0-20mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $199.00
    $234.82 inclGST

  • MI454, Potentiometer and Tap Position Programable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz , Aux Voltage 57.74V,100V,230V,400V,500VAC-AC Voltage Transducer-Iskra Doo-Fastron Electronics Store MI454, Potentiometer and Tap Position Programable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz , Aux Voltage 57.74V,100V,230V,400V,500VAC-AC Voltage Transducer-Iskra Doo-Fastron Electronics Store

    MI454, Potentiometer and Tap Position Programmable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz, Aux Voltage 57.74V,100V,230V,400V,500VAC

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MI 454, Potentiometer and Tap Position Programmable Transducer, Class 0.5, Universal 20 - 300VDC/40 to 276VAC 40 to 70Hz, Aux Voltage 57.74V,100V,230V,400V,500VAC Class 0.5 (EN 60688) Programable DC Voltage Output 0-1V to 0-10V @ 20mA Programmable DC Current Output 0-1mA to 0-5mA, 0-5mA to 0-20mA @ 15V Features : Measurement of up to 500VAC Universal Supply 20 - 300VDC/40 to 276VAC 40 to 70Hz Accuracy class 0.5 Input frequency 40-70Hz Specification Iskra Doo Part Number MI454 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-500VAC Maximum Measurement Range 0-600VAC Output 0-20mA/0-5mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $485.00
    $572.30 inclGST

  • Last stock! MT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms MT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    MT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable analogue outputs, USB, Ethernet, RS485 Comms

    2 pcs in stock

    Iskra Doo MT540-HSHFNAAAA, Multifunction Power Transducer, Class 0.5S, 4 Wire, 600V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, USB, Ethernet, RS485 Comms Class 0.5S Active, Class 0.2 Reactive (EN 60688) , Class 0.2 on Comms RS485 Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 140 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy Class 0.5s Active, Class 0.2 Reactive (EN 60688), Class 0.1 on Comms 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Optional Remote Display Support Specification Iskra Doo Part Number MT540-HSHFNAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 5 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 4 x Analogue Accuracy Class 0.2 (I,U,F,PF,θ,THD) Class 0.5s(Active), Class 0.2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Terminations EU Style Clamp Terminals Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 900g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software

    2 pcs in stock

    $2,099.50
    $2,477.41 inclGST

  • Iskra Doo MT440 S S U S A A N N A, Multifunction Transducer, Class 0.5, 4 Wire, 500V L-N, 5A AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 Comms FE-MT440 S S U S A A N N A MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms

    MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT440-SSUDAANNA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V L-N, 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 2 Programmable analogue outputs, RS485 & USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAANNA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output(s) 2 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS232 2400-115200 b/s (RS485 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $1,032.00
    $1,217.76 inclGST

  • MT406-54, AC Voltage Transducer, Class 0.5, 110VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span Iskra Doo AC Voltage Transducer MT406-11, AC Voltage Transducer, Class 0.5, 500VAC 50/60Hz measurement, 57.7V Supply, 0-1mA output FE-MT406-11

    MT406-54, AC Voltage Transducer, Class 0.5, 110VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT406-54 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-20mA analogue Output Average RMS values of voltage Features : Measurement of up to 132VAC Self Powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-54 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-110VAC Maximum Measurement Range 0-132VAC Output 0-20mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C   Datasheet Product Datasheet  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $199.00
    $234.82 inclGST

  • MT406-24, AC Voltage Transducer, Class 0.5, 63.5VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span Iskra Doo AC Voltage Transducer MT406-11, AC Voltage Transducer, Class 0.5, 500VAC 50/60Hz measurement, 57.7V Supply, 0-1mA output FE-MT406-11

    MT406-24, AC Voltage Transducer, Class 0.5, 63.5VAC 50/60Hz Measurement, Self Powered, 0-20mA output, Fixed zero and span

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT406-24 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-20mA analogue Output Average RMS values of voltage Features : Measurement of up to 76.2VAC Self Powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-24 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 0-63.5VAC Maximum Measurement Range 0-76.2VAC Output 0-20mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $199.00
    $234.82 inclGST

  • Oztherm DC Current Transducer with Adjustable Trip F923 AC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm

    F923 AC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm

    F923 Series AC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of AC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned AC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-AC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet

    $552.00 - $595.00

  • Last stock! AW-3-5-4-5-A4-BN, Power Transducer Panel Mount,3 Phase, 3 wire, Active Power, 240V supply w/ 415V measurement

    AW-3-5-4-5-A4-BN, Power Transducer Panel Mount,3 Phase, 3 wire, Active Power, 240V supply w/ 415V measurement

    1 pcs in stock

    Power Transducer Panel Mount,3 Phase, 3 wire, Active Power, 240V supply w/ 415V measurement Product Datasheet

    1 pcs in stock

    $150.00
    $177.00 inclGST

  • Rishabh Instruments AC Voltage Transducer Rish Con-V-50-O1A1-O200-D-2,  AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display FE-Rish Con-V-50-O1A1-O200-D-2

    Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z, AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display

    6 pcs in stock

    Rishabh Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z, AC Voltage Transducer, Input Programmable True RMS 50Hz 57-500VAC Full Scale, 0-20mA, 60-300VAC Supply, with Display Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con-V(500)-F-H-O1A1-O200-D-Z-Z Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 57 - 500VAC 50/60Hz Overlaod (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1   Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog  

    6 pcs in stock

    $179.00
    $211.22 inclGST

  • MT406-11, AC Voltage Transducer, Class 0.5, 57.7VAC 50/60Hz Measurement, Self Powered, 0-1mA output, Fixed zero and span Iskra Doo AC Voltage Transducer MT406-11, AC Voltage Transducer, Class 0.5, 500VAC 50/60Hz measurement, 57.7V Supply, 0-1mA output FE-MT406-11

    MT406-11, AC Voltage Transducer, Class 0.5, 57.7VAC 50/60Hz Measurement, Self Powered, 0-1mA output, Fixed zero and span

    Out of stock

    Free Aus Post Shipping for $300 Spend

    Iskra Doo MT406-11 Series Single Phase AC Voltage Transducer, Fixed zero and span Class 0.5 (EN 60688) 0-1mA analogue output for Moving Coil Voltmeter Average RMS values of voltage Features : Measurement of up to 69.25VAC Self powered Accuracy class 0.5 Input frequency 50/60Hz Specification Iskra Doo Part Number MT406-11 Functions Single Phase AC Voltage Transducer Supply Voltage Self Powered Nominal Measurement Range 57.7VAC Maximum Measurement Range 69.25VAC Output 0-1mA Tariff Input N/A Accuracy Class 0.5 Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20   Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software  

    Out of stock

    Free Aus Post Shipping for $300 Spend

    $199.00
    $234.82 inclGST

  • Oztherm DC Current Transducer with Adjustable Trip F923 DC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm

    F923 DC Series Current Transducer with Adjustable High and Low Solid State Relay Alarm

    F923 Series DC Current Transducer with Process Outputs & High and Low Sold State Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase DC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 2Amp @ 40VDC, 2Amp @ 60VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet

    $552.00 - $595.00

  • Oztherm DC Current Transducer with Adjustable Trip F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm

    F923 DC Series Current Transducer with Adjustable High and Low C/O Relay Alarm

    F923 Series DC Current Transducer with Process Outputs & High and Low C/O Alarm Features Isolated measurement of DC currents using internal Hall effect transducer. Incorporates an integrated input level display and power supply. Wide measurement range available Choice of standard outputs Wide range isolated DC input supply DIN Rail mounting Signal Conditioned DC measurement output On board bar graph display User adjustable zero offset and span controls Zero insertion loss in current measurement path Earth leakage via differential Ipn for nominal Input ‘01’ Applications Process control Transportation Petrochemical Industrial Earth Leakage Energy Monitoring/Measurement Automation Delivery Delivery in 3-5 days for small qty. Otherwise 4-6 weeks Specification Oztherm Part Number F923-X-XX-DC-XX Functions Single Phase AC Current Transducer Supply Voltage 9-36VDC Nominal Measurement Range 0-8 Amp (Sensor dependant) Maximum Measurement Range 8 Amp Alarm C/O Relay 4Amp @ 30VDC, 0.5Amp @ 150VAC Response Time 250mS Accuracy @ 25 Deg C Class 1 Bandwidth DC - 1kHz linearity < 0.15% Isolation 2.5kV Comms N/A Weight 250g Enclosure Size 79 x 60 x 85mm Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material Polyamide non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP40 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet

    $552.00 - $595.00

Login

Forgot your password?

Don't have an account yet?
Create account