Eastron Europe ESCT-RJ335-125A/100mA, 3 Phase Current Transformer, Class 1, 0.5VA 125 Amp, 100mA Output, Panel Mount
Features
RJ12 EasyClick CT Connections to suit EasyClick SDM630MCT-ML Series
1M RJ12 Cable Supplied
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Eastron Part Number
ESCT-RJ335-125A/100mA
Technology
3 Phase AC Current Transformer
Ratio
125/100mA
Aperture Size
21 x 25mm
VA Rating
0.5VA
Accuracy Class
Class 1
Output
100mAmp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
125Amp x 1.2
Termination Style
RJ12
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh 3PH140-31(40) 500, Class 1 2.5VA 500 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH105-31(40) 500
Technology
AC Current Transformer
Ratio
500/5
Aperture Size
30 x 36mm
VA Rating
2.5VA
Accuracy Class
Class 1 / Class 2
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
500Amp x 1.2
Termination Style
Screw
Unit Weight
1500g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Rishabh 3PH140-31(40) 400, Class 1 2.5VA 400 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH105-31(40) 400
Technology
AC Current Transformer
Ratio
400/5
Aperture Size
30 x 36mm
VA Rating
2.5VA
Accuracy Class
Class 0.5Â / Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
400Amp x 1.2
Termination Style
Screw
Unit Weight
1500g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Eastron Europe ESCT-RJ335-63A/100mA, 3 Phase Current Transformer, Class 1, 0.25VA 63 Amp, 100mA Output, Panel Mount
Features
RJ12 EasyClick CT Connections to suit EasyClick SDM630MCT-ML Series
1M RJ12 Cable Supplied
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Eastron Part Number
ESCT-RJ335-63A/100mA
Technology
3 Phase AC Current Transformer
Ratio
63/100mA
Aperture Size
21 x 25mm
VA Rating
0.25VA
Accuracy Class
Class 1
Output
100mAmp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
65Amp x 1.2
Termination Style
RJ12
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rishabh 3PH185-37(45) 630, Class 1, 5VA 630 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH185-37(45) 630
Technology
AC Current Transformer
Ratio
630/5
Aperture Size
⌀37mm
VA Rating
5VA
Accuracy Class
Class 1 / Class 0.5
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
630Amp x 1.2
Termination Style
Screw
Unit Weight
1500g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Rishabh 3PH140-31(40) 300, Class 1 2.5VA 300 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH105-31(40) 300
Technology
AC Current Transformer
Ratio
300/5
Aperture Size
30 x 36mm
VA Rating
2.5VA
Accuracy Class
Class 0.5 / Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
1500g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Rishabh 3PH105-21(40) 250, Class 1 1.5VA 250 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH105-21(40) 250
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
20 x 24mm
VA Rating
1.5VA
Accuracy Class
Class 0.5 , Class 1Â
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Rishabh 3PH105-21(40) 125, Class 1, 1.5VA 125 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Rishabh Part Number
3PH105-21(40) 125
Technology
AC Current Transformer
Ratio
125/5
Aperture Size
20 x 24mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
125Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Hobut CT105F-250/5-2.5/1 Class 1, 2.5VA 250 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT105F-250/5-2.5/1
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Over Current (max)
250 Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Hobut CT105F-160/5-2.5/1 Class 1, 2.5VA 160 Amp, 5 Amp Output, 3 Phase Current Transformer, With Feet Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Hobut Part Number
CT105F-160/5-2.5/1
Technology
AC Current Transformer
Ratio
160/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
160Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Hobut CT105D-100/5-2.5/1 Class 1, 2.5VA 100 Amp, 5 Amp Output, 3 Phase Current Transformer, Din Rail Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Hobut Part Number
CT105D-100/5-2.5/1
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
21 x 25mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
100Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â
Eastron Europe ESCT-RJ335-100A/100mA, 3 Phase Current Transformer, Class 1, 0.5VA 100 Amp, 100mA Output, Panel Mount
Features
RJ12 EasyClick CT Connections to suit EasyClick SDM630MCT-ML Series
1M RJ12 Cable Supplied
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Â
Specification
Eastron Part Number
ESCT-RJ335-100A/100mA
Technology
3 Phase AC Current Transformer
Ratio
100/100mA
Aperture Size
21 x 25mm
VA Rating
0.5VA
Accuracy Class
Class 1
Output
100mAmp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
125Amp x 1.2
Termination Style
RJ12
Unit Weight
450g
Factory Pack Qty
9
Â
Datasheet
Product Datasheet
Â