Search results for "프라다지갑가격 싸싸숴러닷컴 sssreo 탤ㄹh문의 50대루이비통가방추천 정품동일급 의령군최고퀄리티 미러급 레플리카 구찌뱀"
-
ISPRO-K BSR 100/440 (3+1), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 100kA, 440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Iskra ISPRO-K BSR 100/440 (3+1), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 100kA, 440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Specifications Iskra Doo part number ISPRO-K BSR 100/440 (3+1) Nominal Voltage 440VAC No of Poles 3 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Overhead power lines Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Additional Remote Contacts YES Protective element MOV + GDT Surge discharge rating Imax up to 75 kA Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$612.00
$722.16 inclGST -
D53TP50DH + KS300, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator, Cover + HSP-3 Thermal pad.
Crydom D53TP50DH + KS300, SSR 3 Phase 4-32VDC Control, 50A, 48-530VAC Load, LED Status Indicator, Cover + HSP-3 Thermal pad. Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number D53TP50DH + KS300 Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 50 Amp (rms) per Phase Surge Capability 597 Amp (peak) Special Feature LED Status Indicator + IP20 Cover + Thermal Pad Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
$384.46
$453.66 inclGST -
ISPRO-K BSR 75/440 (3+0), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Iskra ISPRO-K BSR 75/440 (3+0), Class I,II / Type 1,2 / B,C, Surge Protection Device (SPD) with Remote Contact, 3 Pole 75kA,440VAC, DIN Rail Mount Specifications Iskra Doo part number ISPRO-K BSR 75/440 (3+0) Nominal Voltage 440VAC No of Poles 3 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Protective element MOV + GDT Surge discharge rating Imax up to 75 kA, or 25kA per pole Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$419.00
$494.42 inclGST -
ISPRO BSR 25/440, Class I, II / Type 1,2 / B, C, Surge Protection Device (SPD) with Remote Contacts, 1 Pole 25kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT
Iskra ISPRO BSR 25/440, Class I, II / Type 1,2 / B, C, Surge Protection Device (SPD) with Remote Contacts, 3 Pole 37.5kA,440VAC, DIN Rail Mount, L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Specifications Iskra Doo part number ISPRO BSR 25/440 Nominal Voltage 440VAC No of Poles 3 Category IEC / EN / VDE Class I,II / Type 1,2 / B,C Location of use Main Distribution Boards Protection modes L/N-PE, L-PEN, L-N, N-PE High Energy MOV and GDT Additional Remote Contacts YES Protective element MOV + GDT Surge discharge rating Imax up to 25 kA Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet
$138.70
$163.67 inclGST -
ART-B22-D300-SP4 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 30cm Diameter, SP4 = 4.5M Integrator Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D300-SP4 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 30cm Diameter, SP4 = 4.5M Integrator Cable The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D300-SP4 + AI-P1A - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp output Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 30cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 4.5M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.