VX9-UCMA-A2, Temp Controller, 96x96mm, 100-240VAC, 4-20mA Output, Relay Cooling 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX9-UCMA-A2
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
N/A
Option 2
N/A
Mounting Style
96 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
450g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Risbabh LM1360-MA4L-4-3-01-02-U-H-2, Panel Mount kWh Meter, Class 0.2S, 1/5Amp input, 2 Pulse Outputs, RS485 & USB Comms, Three Section LCD Display, Internal Logging
2 Pulse Outputs
Nominal current up to 1.2/6 A (For 1/5A CT Input) and nominal voltage up to 240V L-N
Three Section Display
RS 485 communication up to 19,200 bit/s
USB Port
8MB Internal Storage
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
THD up to 31sth Harmonic
85 Parameter Measurement
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.2
Simple Menu
RS 485 communication up to 19,200 bit/s
USB Comms
8MB Internal Logger
240V AC power supply
Specification
Rishabh Part Number
LM1360-MA4L-4-3-01-02-U-H-2
Functions
kWh Meter, Energy Meter
Supply Voltage
240VAC < 5VA
Nominal Measurement Range
600V L-L 350V L-N, 5 Amp
Maximum Measurement Range
600V L-L 350V L-N, 6 Amp
Display
Three Line LCD
Pulse Output
2 (input or output)
Accuracy
Class 0.2S (kW,kWh) Class 0.5(Active) Class 2(kVar,PF)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
Ethernet
Optional
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Xmer CT Split 125/50SC 300/5 Class 1 3.75VA, 55 x 85mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 125/50SC 300/5 Class 1 3.75VA
Technology
Split Core AC Current Transformer
Ratio
300/5
Aperture Size
55 x 85mm
VA Rating
3.75VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
1.25kg
Factory Pack Qty
9
Datasheet
Product Datasheet
VX2-UCNA-A2D2, Temp Controller, 48x96mm, 100-240VAC, Multirange Input, 4-20mA Output, 2 Alarms, 2 x SV
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UCNA-A2D2
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
2 x SV Input (2 Setpoint Selection/External Setting Input)
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
VX4-USMA-A2, Temp Controller, 48x48mm, 100-240VAC, Multirange Input, SSR Output, Relay Cooling 2 Alarms
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX4-USMA-A2
Control Output 1 (Heat)
SSR 12-15VDC @30mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
2nd Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
N/A
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Current Transducer, AT-AA9-D-4, AC Current Transducer, Average RMS, 5 Amps, 24VDC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA8-D-4
Control Output
0-10V Average RMS
Input
0-5 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
LEM DVM 4000-UI, Digital Voltage Transducer, Vpn = 4000V, 24VDC Supply, 4-20mA Analogue Output, 12kV Isolation
Features
Bandwidth DC to 13kHz
4-20mA Unipolar Analogue Output
Closed loop transducer using Hall effect
Digital Transducer
Compact and versatile
Panel Mount
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
High accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Voltage overload capability
Low power consumption
Applications
Railway substation or locomotive
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Water Treatment Electronics
Specification
LEM Part Number
DVM 4000-UI
Technology
Closed Loop Hall Effect
Aperture
No Aperture
ROHS
Yes
Supply Voltage
24 VDC, Isolated
Primary Nominal Voltage (RMS + DC)
+/- 4000V
Measurement Range
+/- 6000V
Output
4 mA at 0V, to 20mA @Vpn
Isolation
12 kV
Bandwidth
DC-13 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
M5 Screw
Unit Weight
375g
Factory Pack Quantity
4
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Fastron Electronics GBMT-4-K-ANNNY, 140x420mm Digital Panel Meter, Type K Thermocouple Input, 100-240VAC/VDC supply, with IR Remote Control, RS485 Modbus RTU
Adjustable Zero and Span Setting
Adjustable Display Scaling
Remote Control Included
Modbus RTU RS485
Wall Mount
LED Tile Display
Large 4 Digit 100mm (40 Inch) LED Display
250mS Response Time
PC 94 UL V0
100mm Depth
CE Approved
Specification
Fastron Electronics Part Number
GBMT-4-K-ANNNY
Conditioner Output
N/A
Input
Type K Thermocouple -200°C to 1360°C
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Comms
RS485 Modbus RTU
Termination Style
Screw
Mounting Style
140 x 420 mm Wall Mount
Case Material
PC - UL 94 V0
Weight
3.6kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron Electronics AM5A-A-DV1-A Digital Panel Meter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5P-C4225A-NAN
Signal Conditioned Output
4-20mA
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Fastron Electronics AM5H-A-D-V5-A-R4-AN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 100-240VAC/DC supply, 4 x Relay Alarms, Digital Panel Meter & Transmitter, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-D-V5-A-R4-AN
Conditioner Output
4-20mA
Input
0 - 36VDC
Alarms
4 x Hi/Low, 7 Amp @ 277VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Magnelab MCT-0016-050, 5 Amp, Loop Powered AC Current Transducer, Average RMS, 4-20mA Output, Accuracy +/-2% (Ripple)
Features
Average RMS Output
Split Core
4-20mA Current Output
Cable Mounting
20-30VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
UL, CE, ROHS Approved
Advantages
Large aperture for cable up to ⌀ 24mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
Magnelab Part Number
MCT-0016-005
Technology
AC Current Transducer
Protection Class
IP50
Supply Voltage
20-30VDC Loop Powered (10mA)
Load Current (RMS)
5 Amp
Output
4-20mA (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
50 - 60Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
+/-2% Ripple on output
Termination Style
Screw
Aperture
16mm
Approvals
UL, CE, ROHS
Unit Weight
170g
Factory Pack Qty
6
Datasheet
Product Datasheet