Fastron Electronics AM5S-C-VE-D-N, 48x24mm Digital Totaliser 7kHz, 24VDC, 22-60VAC/DC supply
Large 5 Digit 0.4 Inch LED Display
250mS Response Time
PC 94 UL V0
Input signals can be NPN, PNP, or 24VDC Pulses depending on the model used
Each unit needs just 48 x 24mm Panel Space
86.2mm Depth
Specification
Fastron Electronics Part Number
AM5S-C-VE-D-N
Input
Up to 24VDC
Measurement Range
0 - 7kHz
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Termination Style
Screw
Mounting Style
48 x 24mm Panel Mount
Case Material
PC - UL 94 V0
Safety Approvals
CE
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
Fastron FC5-S-W-1-G-4-C, 24VDC PID Controller with 1 Alarm, RS485 K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-W-1-G-4-C
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA
Input
Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
1 Alarm standard
Mounting Style
48 x 48 Panel Mount
Supply Voltage
24VDC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron Electronics AM5A-A-DV1-A Digital Panel Meter & Transmitter
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5P-C4225A-NAN
Signal Conditioned Output
4-20mA
Input
0 - 50mVDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
110- 240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Fastron Electronics AM5H-A-D-V5-A-R4-AN, 96x48mm Digital Voltmeter 0-36VDC with 4-20mA output, 100-240VAC/DC supply, 4 x Relay Alarms, Digital Panel Meter & Transmitter, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-D-V5-A-R4-AN
Conditioner Output
4-20mA
Input
0 - 36VDC
Alarms
4 x Hi/Low, 7 Amp @ 277VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Current Transducer, GMTA-DV4-A-RN, DC Voltage Transmitter with Alarm, 0-10V DC Input, 100-240VAC/DC Aux, 1 x Relay Output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals, Currents up to 10 Amp, and Voltages up to 600VAC or DC, can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type), or given alarm Setpoint.
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Part Number
GMTA-DV4-A-RN
Control Output
1 x Relay
Input
0-10VDC
Alarm Type
1 x SPST NO Relay 3 Amp
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Magnelab DVT-1000-420, DC Voltage Transducer, Din Rail Mount, 10-1000VDC, 4-20mA output, 15-48VDC Supply Voltage, 10mS Response
10mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Magnelab Part Number
DVT-1000-420
Control Output
4-20mA
Input
10 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
15 - 48VDC
Voltage Isolation (1 min)
4.5kV
Accuracy
1%
Response Time
10mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
UL508C, CSA C22.2
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Rish Xmer Split Core 2500/5 Amp 195/80 Class 0.5, 25VA Series Current Transformer, 85 x 172mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Electronics Part Number
Rish Xmer Split Core 2500/5 195/80
Technology
Split Core AC Current Transformer
Ratio
2500/5
Aperture Size
172 x 85mm
VA Rating
25VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
2kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Northern Design XD-R420-2, Current Transducer, True RMS, Ipn = Selectable 5,10,15,20,25,30 Amp, 4-20mA out,16-36VDC Loop powered
Features
Ipn = Selectable 5,10,15,20,25,30 Amp
True RMS Output
4-20mA Current Output
Din Rail Mounting
16-36VDC Loop Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ⌀ 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Earth Leakage Measurement
Motor Control
Actuators
Lamp Failure
Specification
Northern Design Part Number
XD-R420-2
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
16-36VDC Loop Powered (10mA)
Load Current (RMS)
Selectable 5,10,15,20,25,30 Amp
Output
4-20mA (True RMS)
Isolation
4kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
Class 1
Termination Style
Screw
Unit Weight
180g
Factory Pack Qty
6
Datasheet
Product Brochure
Product Manual
Application Notes
Fastron FDV-1000-420-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 4-20mA output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-1000-420-24
Analogue Output
4-20mA
Input
0 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AM5H-A-DV5-AR4AN, 96x48mm Digital Voltmeter 0-36VDC, 4-20mA Retransmission, 4 Relay Alarms, 20-60VDC supply, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-DV5-AR4AN
Conditioner Output
4-20mA
Alarm Outputs
4 x Relays 7 Amp @ 277VAC
Input
0 - 36VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
20-60VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Display Type
5 Digit RED LED
Termination Style
Screw
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Shinko JCL33AS/M-DR Series Digital Indicating Controllers
• Program control, converter function are standard features
• 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
• Drip-proof / Dust-proof IP66 (front panel only)
• 9-step pattern (for SV and time) is a standard feature
• UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
• Each unit needs just 24 x 48mm panel space
• EC Compliant (Details)
Specification
Shinko Part Number
JCL33AS/M-DR
Control Output
SSR Drive 12VDC +/-15% @ 40mA
Input
Multirange (refer to datasheet)
Alarm
1 x Open Collector(100mA)(EV2)
Option
Relay Cooling Output (EV1)
Mounting Style
24 x 48mm Panel Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
120g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
Download Datasheet
Download Manual
Delivery in 2-3 weeks if not in stock.
RCS-1200-1000 0.333V, 3 Phase 1000Amp AC Measurement 4 Inch ⌀ Rogowski Coils with Integrator, Class 1 Flexible Current Sensor System:
The RCS-1200 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1200 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-1000
Specification
Magnelab Part Number
RCS-1200-1000
Function
AC Current Measurement
Nominal Measurement Current
1000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
4 Inch
Coil Circumference
12 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes