HS212, Heatsink 110mm, Milled, Drilled and Tapped for Single & 3 Phase SSR, 1°C/W
Specifications
3 x 20 Amp @ 40 Deg C
Panel Mount
Datasheet
Product Datasheet
Heatsink products are mostly made to order and require 2-3 days more to produce.
Schurter ILR-11-0001 (ILR1-11-3), Pulse Transformer
Features
High insulation rating (>2.2 kVAC) between the primary and the secondary windings
Small coupling capacitances between primary and secondary windings limit transient feedback from the power supply side to the control electronics
Cost optimized design
The defined partial discharge voltage guarantees an effectively unlimited serviceable live
Applications
Galvanic separation of drive and power-circuit
Mainly used in ignition circuits with Thyristors, Triacs, power transistors and IGBT's
DC/DC converters
Line coupling transformers in high speed data transmission
Specification
Schurter Part Number
ILR-11-0001 (ILR1-11-3)
Rated Voltage
500V
Rated Current (Iz)
1000mA
Inductance
25mH
Transformer Ratio
1:1
Rated Power (Pm)
0.5W
Resistance (RL)
10Ω
Rise Time (Tr)
0.3uS
Operating Temperature
-25°C to 125°C
Mounting
PCB Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
THT Terminals
Weight
14g
Factory Pack Qty
1
Climatic Category
40/125/21 acc. to IEC 60068-1
Isolation
3.2kV
VDE/UL/CSA/ROHS
Yes
Datasheet
Product Datasheet
Shinko WCL13A-AA/MM Series Dual Loop Digital Indicating Controllers
Differential control, Tank level control, converter function are standard features
5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
9-step pattern (for SV and time) is a standard feature
UL/CSA Approved
• Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant (Details)
Note the WCL13A Series Requires Open Ring Lug ask-002-1 or Touch Proof ask-001-1 Terminal base to function.
Specification
Shinko Part Number
WCL13A-AA/MM
Control Output 1
4 - 20mA
Control Output 2
4 - 20mA
Input
Multirange (refer to datasheet)
Option
None
Mounting Style
Din Rail Mount
Supply Voltage
100 - 240VAC
Termination Style
Screw
Weight
180g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
WCL Series Brochure
WCL 2014 Additions Brochure
WCL Series User Manual
Delivery 2-3 weeks delivery if not in stock
Rishabh 3PH105-21(40) 250, Class 1 1.5VA 250 Amp, 5 Amp Output, 3 Phase Current Transformer, Panel Mount, Busbar Mount
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
3PH105-21(40) 250
Technology
AC Current Transformer
Ratio
250/5
Aperture Size
20 x 24mm
VA Rating
1.5VA
Accuracy Class
Class 0.5 , Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
250Amp x 1.2
Termination Style
Screw
Unit Weight
1000g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics SCT-F24-25, 0.333v, 25Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-25
Technology
Split Core AC Current Transformer
Ratio
25/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
25Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics GT-D-A6-A-1, Signal Isolator/Conditioner, 4-20mA input, 100-240VAC/DC aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-D-A6-A-1
Control Output
4-20mA
Input
4-20mA
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F36-5, 0.333V, 5Amp measurement Split Core CT's Class 1, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
1/4" BSPT x 6mm Compression Fitting for use with RTD or Thermocouple, 304 SS Body with Brass Compression Ring Insert
Tapered 1/4" BSP x 6mm
Stainless Steel
BSPT vs NPT Sizes
BSPT vs NPT Fittings
TRB-BG25, Toggle KeySwitch 2 Pos Latched Black 1NO + 1NC, IEC60947-5-1
Toggle Switches are used to Toggle between 2 or 3 Digital or Analogue Input Signals or to simply turn off control signals. Widely used for Rugged Industrial Applications Including Critical Machinery requiring safe and reliable repetitive operation by the user.
Features :
600V Insulation Rating
240VAC @ 3 Amp
22mm Cutout
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRB-BG25
Functions
2 Pole, 3 Position Toggle Switch
Switch Type
Latching 1 x NO, 1 x NC
Nominal Voltage
240VAC @ 50/60Hz
Rated Impulse Voltage
6kV
Nominal Current Range AC
3 Amp @240VAC
Rated Insulation Voltage
600VAC
Humidity
35-85%
Approvals
CE
Standards
IEC60947-5-1, IP20 (IP40 Installed)
Weight
65g
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Trent F170H0069 Series Fuse Indicator for NH Fuses
Features
To Suit trent or Bussmann Nh Fuse with Indicator
Applications
Fault Monitoring/Detection
Specification
Trent Part Number
F170H0069
Contact Rating
1 Amp 250VAC
Operating Temperature Range
-40°C / 125°C
Unit Weight
30g
Factory Pack Qty
10
Datasheet
Fastron Electronics SCT-F24-160, 0.333v, 160Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-160
Technology
Split Core AC Current Transformer
Ratio
150/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
160Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Fastron Electronics SCT-F24-50, 50Amp/0.333V Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
333mV Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-50
Technology
Split Core AC Current Transformer
Ratio
50/333mV
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
333mV (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide