Fastron Electronics SCT-F24-5, 0.333v, 5Amp Measurement, Class 1 Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F24-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 24 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
TRV-22D-R-400, 22mm LED Voltmeter RED 20-500VAC, Plastic, IP40, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
400VAC Supply
20-500VAC Measurement
LED Illumination
Ø 22.5mm Cutout
Long Life
LED Replacement Beads Available
RED, GREEN, AMBER, BLUE, or Clear\White Colour
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRV-22D-R-400
Functions
LED Voltmeter
Measurement Range
20-500VAC
Nominal Voltage
400VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Blue LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron Electronics SCT-F10-50-1A, 1 Amp Output, 50Amp Measurement, Class 1 Split Core CT's Class 1
Features
Quick Release Split Core System
Cable Mount
1 Amp Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-50-1A
Technology
Split Core AC Current Transformer
Ratio
50/1Amp
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
1 Amp (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
Crydom ED10D5, EMR plug in Solid State Relay, 5-15VDC control, 5 Amp 1-80V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED10D5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 80VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
RCS-2400-1500 Three-Phase Flexible Current Sensor System(Rogowski Coils):
The RCS-2400 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-2400 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Specification
Magnelab Part Number
RCS-2400-1500
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
1500 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 1500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
8 Inch
Coil Circumference
24 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Fastron Electronics ESCT-TA36-300A/100mA + HY-2.0, 300A/100mA Measurement, Class 1 Split Core CT's, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
100mAmp Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads with HY-2.0 Connector
Applications
Eastron Modular Metering Equipment
Energy Monitoring
Load Balancing
Power Quality Measurements
Specification
Fastron Part Number
ESCT-TA36-300A/100mA + HY-2.0
Technology
Split Core AC Current Transformer
Ratio
300/100mA
Aperture Size
ø 36 mm
VA Rating
1VA
Accuracy Class
Class 1
Output
100mA (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.9M Flying leads with HY-2.0 Connector
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
CRJ-31 Connector User Guide
TRA-22D-B-230, 22mm LED Ammeter BLUE 0-100Amp 240VAC, Plastic, IP40, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC Supply
0-100Amp Measurement via included solid core CT
LED Illumination
Ø 22.5mm Cutout
Long Life
LED Replacement Beads Available
RED, GREEN, AMBER, BLUE, or Clear\White Colour
Standards :
IP40
IEC60947-5-1
CE
Specification
TRENT Part Number
TRA-22D-B-230
Functions
LED Ammeter
Measurement Range
0-100Amp AC (via included solid core CT)
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Blue LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRI-22-Y24, 22mm LED Indicator AMBER 24VAC/DC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
24VAC/DC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-Y24
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
Amber LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
TRI-22-W240, 22mm LED Indicator WHITE 240VAC, Plastic, IP65, IEC60947-5-1
LED indicator Series will activate while the contacts are connected to the rated voltage. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation and visual Indication by the user.
Features :
240VAC or 24VAC/DC (400VAC Special Orders)
LED Illumination
Ø 22.5mm Cutout
Long Life
Replacement Beads Available
Standards :
IP65
IEC60947-5-1
CE
Specification
TRENT Part Number
TRI-22-W240
Functions
LED Indicator Only
Nominal Voltage
230VAC @ 50/60Hz
Impulse Voltage Wear Resistance
6kV
Illumination Type
White/Clear LED
Short Circuit Protection (Fuse)
Recommend 10A gG Fuse
Mechanical Compression Force at Closing
20N
Mechanical Compression Force at Closing
8N
Humidity
35-85%
Approvals
CE
Standards
IP65, IEC60947-5-1
Weight
Enclosure Material
UL94V0
Factory Pack Qty
1
TRENT(Fastron) Head Office
Australia
Datasheet
Product Datasheet
Fastron Electronics SCT-F36-50, 0.333V, 50Amp measurement Split Core CT's Class 1, 36mm Aperture
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F36-50
Technology
Split Core AC Current Transformer
Ratio
50/0.333V
Aperture Size
ø 35 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
50Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
400g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Northern Design Multicube Modular Master Single and 3 Phase Power Meter with RS485
Up to 20 Meters in 1 with additional modules
Minimum 2 x 3 Phase Circuits with measurement module
Master Unit of Modular Multicube System
Optional 12 way pulse/alarm digital output modules
Nominal current up to 0.383V (For 0.333V CT Input) and nominal voltage up to 240V L-N 415V L-L
Graphic Display
Optional RS485 or Ethernet communication up to 19,200 bit/s
True RMS measurement of currents and voltages
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, reactive power, power factor, harmonics, etc.) from the measured signals.
Features :
20 Meters in same space as 4 traditional meters
Expandable to 20 x 3 Phase or 60 x Single Phase Circuits
Accuracy class 1
In Built Logger
Simple Menu
Optional MODBUS RTU RS485 communication up to 19,200 bit/s or Ethernet communication
5 Year Warranty
240V AC power supply
Specification
Northern Design Part Number
Multicube Modular Master with Logger
Functions
kWh Meter, Energy Meter, Power Quality, Network Recorder
Supply Voltage
240VAC < 15VA
Nominal Measurement Range
415V L-L 240V L-N, 0.333V
Maximum Measurement Range
480V L-L 280V L-N, 0.383V
Display
Graphic LCD
Pulse Output
12 (Optional)
Accuracy
Class 1 (kW,kWh) Class 1(Active), Class 2 Reactive
Ethernet
Optional
Logger
Optional
Isolation
2.11kV
RS232/RS485
Modbus RTU RS485 2400-19200 b/s
Weight
900g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
ABS with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
164 x 96mm x 100mm
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product brochure
User manual
Wiring Diagram
Suitable 0.333V CT's
Split Core CT's