SDM230-LORAWAN-MID-AD915, DIN Rail Mount kWh Meter, Single Phase, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms, MID Approved
100 amp Direct Connect
LoRaWaN AU915 communication
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM230-LORAWAN-MID-AU915
Functions
Single Phase Energy Meter
Supply Voltage
N/A
Nominal Measurement Range
230V L-N 230V L-N, 100 Amp
Maximum Measurement Range
276 L-N 230V L-N,100 Amp
Nominal Current Input
Direct connect 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
LoRaWaN
LoRaWaN AU915
Weight
250g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Modbus Utility
EEM Meter Setting Software Utility
GIC Controls, LA25F1 90-264VAC, Hours Run Meter 90-264VAC, 48x48mm Panel Mount
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
48x48mm Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
Sanrex MBR600100CT, Schottky Diode Rectifier Module, 600 Amp, 100V, NON Isolated BRA PACK
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
2500V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
GeneSiC Part Number
MBR600100CT
Vrrm
100V
Diode Configuration
Schottky Diode Rectifier - Common Cathode
IF(av) @ 125 Deg C (50% Duty)
400 Amp per device, 200 Amp per leg
Package Size
W:20mm L:93mm D:16.5mm
Itsm
4.0 kA
VF(to)
0.84V
Tj(max)
150°C
rF
Not Published
Terminals
1/4"-20UNC
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
R th(c-h)
0.28°C/W
Weight
68g
Mounting Torque
40 Nm (40 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Datasheet
Product datasheet
GIC Controls, LA25F1 90-264VAC, Hours Run Meter 90-264VAC, 48mm Round Panel Mount
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
48mm Round Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
GIC Controls, LA21F1 90-264VAC, Hours Run Meter 90-264VAC, 37x24mm Panel Mount
Features
IP40 (IP66 with Gasket)
90-264VAC
6 Digit Display
99999.9 Hours
37x24mm Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
M3 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V (For Non Insulated Busbar or wire)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
For Non Insulated or Insulated Busbar/ Bare Wire
Rated System Voltage 0.6/3kV (1 Min) NOTE: 30V only with Non Insulated cables, see M2 for 600V Insulated types.
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M3.10.2mA,M3.100.0.1V,M3.100.100mA,M3.100.1A,M3.100.1V,
M3.200.1A,M3.200.2V,M3.UM.1A.1V,M3.UM.50A.1V,M3.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz (customised on request)
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
Littlefuse-IXYS, Single Phase Diode rectifier Bridge, 50Amp, 1600V, Single Phase Diode Rectifier Bridge, 50Amp, 1200V, Replaces Semikron SKB52/16 SKB50/16 IXYS PSB55/16
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
IXYS Part Number
VBO50-16N07
AC Line voltage
533V
Device Configuration
Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
50 Amp
Package Size
W:72mm L:60mm D:28mm
Itsm
750 A
VF(to)
0.85V
Tj(max)
150°C
rF
11mΩ
Terminals
M5 (5Nm)
Hole Centres
60mm (M5)
Gate Terminals
N/A
R th(j-c)
2.6°C/W
R th(c-h)
0.24°C/W
Weight
260g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
IXYS Headquarters
USA
Datasheet
Product Datasheet
Alternatives
See PSD51/18 for Faston Terminal equivalent
RCS-1800-4000 0.333V, 3 Phase 4000Amp AC Measurement 6 Inch Rogowski Coils with Integrator, Class 1:
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-3000
Specification
Magnelab Part Number
RCS-1800-4000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
4000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 3000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
RCS-1800-5000, 0.333V, 3 Phase 5000Amp AC Measurement 6 Inch Rogowski Coils with Integrator, Class 1:
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-3000
Specification
Magnelab Part Number
RCS-1800-5000
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
5000 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 3000 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
DRG-01 (Generic 35mm DIN Rail Adaptor), UL94V0 DIN Rail Clips for Converting Panel Mount devices, Includes 2 mounting screws and 2 side clips, F2.90.98.000.1
SPD1-DC/3-1500/40, 1500VDC Surge Protection Device for Photovoltaic Systems, Type 2
Specifications
Trent part number
T1-1500PV-3+0-S(-R)
Nominal Voltage
1500VDC
No of Poles
3
Category IEC / EN / VDE
Type 2
Location of use
String Box, Inverter
Protection modes
(+)-PE,(-)-PE,(+)-(-) PE
Additional Remote Contacts
NO
Protective element
MOV
No Fault/Fault Indication
Green Flag / Not Green Flag
Surge discharge rating
Per pole 40kA (8/20uS)9KA) Max, 20kA (8/20uS)9KA) Nominal
Internal protection and safety
Thermal disconnector in each MOV
Weight
420g
Standards
IEC50539-11 (TUV Approved)
Datasheet
Product Datasheet
GDT/MOV/TVS Tester
SPD Tester
Risbabh EMDC 6002-1000-HA-C-4R, 4 Channel DC kWh Meter, Class 0.5, 150-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, 4 Line LCD Display, 60-300VAC/DC Aux Supply, Internal Logging, 4 x Configurable Relay Alarms
4 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 201-1000VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DC power supply
Specification
Rishabh Part Number
EMDC 6002-1000-HA-C-2R
Functions
4 Channel DC kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
201-1000VDC
Maximum Measurement Range
201-1000VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YES 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
IP54
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
96 x 96mm x 83.5mm (72mm behind panel)
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.