E62.G85-682G10, 6.8uF, 40x58mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 1000VDC/640VAC
Characteristics and utility
6.8uF 1000VDC/640VAC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M12 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.G85-682G10
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø50x85mm
Mounting
M12 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
1000VDC/640VAC
Operating Temperature Range
-40 to 85 °C
Capacitance
6.8uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
Faston
Unit Weight
0.07kg
Factory Pack Quantity
21 (MOQ = 105)
Datasheet
Product Datasheet
Secure Elite E500C-5202, Panel Mount Network Recorder with Harmonics (15th) & PQ Parameters, Class 0.5S, 50..500VAC 50/60Hz, RS485 Modbus RTU, 35..300V DC/85..300VAC Aux, 16MB Dual Logger , TFT Touch Screen, 10 Years Warranty
Automatic range of nominal current up to 6 A (Includes 5A/1A CT Input) and nominal voltage up to 500 V L-L, 300V L-N
Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs
Dual Loggers, configurable for Instant or accumulated energy
Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs
RMS values of currents and voltages
Measurements of active, reactive, apparent power and power factor
Measurements of energy in all 4 quadrants Average values of measurands per interval
RS 485 communication up to 38400 bit/s as standard
Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850
Optional Modules for Analogue outputs and Relay Alarms
The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals.
Features :
Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 15th
Accuracy class 0.5S
Dual Internal Loggers
Measurement of 20 minimal and maximal values in different time periods
RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication
MODBUS communication protocol
Optional Protocol Modules Modbus TCP, BACNet IP, Profinet, SCADA EC61850
Configurable 2 x Tariff Inputs or 2 x Pulse Outputs, or Alarm Outputs
Universal or AC/DC power supply
Graphic Colour TFT 320 x 240 pixels (53x70mm)
Automatic range of nominal current up to 6 A and nominal voltage up to 500 V
Multilingual support
User-friendly Free ECon Configuration software
Specification
Secure Part Number
E500C-5202
Functions
Power Quality Meter(15th Hamonic), Energy Meter, Network Recorder
Supply Voltage
Universal 35..300V DC, 85..300VAC
Nominal Measurement Range
240V L-N, 1/5 Amp, 415V L-L 1/5 Amp
Maximum Measurement Range
300V L-N, 1/5 Amp, 500V L-L 1/5 Amp
Alarm
Optional Module 2 Relay/Pulse Outputs
Tariff/Digital Inputs
TOU Tarriff Clock
Accuracy
Class 0.5S (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive)
Analogue Output
Optional Module 2 x Programmable Analogue Outputs
Internal Memory
2 x 8MB
Battery Backup
N/A
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS232/RS485
N/A Optional
CT Termination
Ring Terminals
Weight
600g
Certification
CE, CSA, ROHS
Warranty
10 Years from dispatch from Secure Warehouse
Factory Pack Qty
1
EU Directives
Degree on electrical equipment designed for use within certain voltage limits URLRS 53/00 (Directive 73/23/EEC on low voltage): SIST EN 61010-1:2002
Safety Requirement for electrical equipment for measurement, control and laboratory use, part1 : general requirement
Decree on electromagnetic Compatibility (EMC) URLRS 61/00 (Directive 89/336/EEC on electromagnetic compatibility): SIST EN 61036 item 4.5: 1998 Meters for active energy (class 1 and 2)
Safety
Protection Class II
600V rms, installation category II
300V rms, installation category III
Pollution Degree 2 in compliance with SIST EN 61010-1:2002
Enclosure Material
PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0
Enclosure Protection
IP52 (IP00 for terminals) in compliance with SIST EN 60529:1997
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C
Datasheet
Product Datasheet
Cross Reference
The Following meters are close equivalents to Elite 500 Series. For further details please contact Fastron Sales Team
Elite 500_400_300_100 series competition replacement for
Schneider
Siemens
Accuenergy (RS485 +DNP3 default)
Socomec
Selec
PM 5000 series
PAC 2000 series
ACCUVIM-CL + DNP3.0
DIRIS A-20
Selec MFM376
PM 5100
PAC 3200
ACCUVIM-CL + DNP3.0
DIRIS A-20
MFM384, CL-1, RS485
PM 5300
ACCUVIM-IIR
DIRIS A-20
MFM383A
PM 5500
PAC 4200
ACCUVIM-IIR(+ BACnet)
DIRIS A-20
MFM384. RS485
PM 6463
Siemens 7KMPAC4200
ACCUVIM-IIR (+ Profibus)
DIRIS A-30/ DIRIS - A60 (PQ Feature)
MFM384-C-CE-CL05, RS485
PM 5650
ACCUVIM-IIR (+ IEC 61850)
DIRIS A-30 + Profibus
MFM384-C-CE-CL05, RS485
PM 5760
ACCUVIM-EL
DIRIS A-30 +Ethernet
MFM384-C-CE-CL05, RS485
PM5330
ACCUVIM-EL (+ BACnet)
DIRIS A-30/ DIRIS A-60
PM 5560
ACCUVIM-EL (+ Profibus)
DIRIS A-30/ DIRIS A-60
DM6200H
ACCUVIM-EL (+ IEC 61850)
PM2220
ACCUVIM-II R +Ethernet
PM2230 / DM2120 (LED)
PM 5350
Trent I²t Semiconductor Fuse, NBR-FWP-600A 700V AC/DC, Semiconductor Fuse, 600 Amp, 700VAC/DC, Round Barrel 7.09 x 2.0 x 2.5 Inches. Clearing I2t 250kA, Breaking Capacity 200kAand Microswitch
Features
Square Body DIN 43 653
Wide Range of I²t
Ratings up to 2000 Amp
Busbar or Fuse Holder Mounted
IEC Standard 60269.1 AND 4
690 V Voltage Rating complying with IEC 33
Fuse Blown Indicator and Microswitch
Applications
Protection of High Powered Semiconductors according to I²t
Short Circuit Protection
DC or AC Motor I²t Protection
Battery Fuse
Specification
Trent Part Number
NBR-FWP-600A 700V AC/DC
Fuse Type
I²t AR Class
Nominal Voltage
700VAC @ 50Hz
I²t Rating (660V)
250000A²/s
Nominal Current (RMS + DC)
600 Amp
Tested Breaking Capacity
200kA @ 700VAC/DC
Dimensions
138 x 61 x 50mm
Hole Centers
108mm +
Mounting Style
Busbar or Panel Mount with Standoff
Operating Temperature Range
-40°C / 125°C
Watts Dissipation
75W
Termination Style
M10
Unit Weight
350g
Factory Pack Qty
10
Datasheet
Product Datasheet
Sanrex MBR600100CT, Schottky Diode Rectifier Module, 600 Amp, 100V, NON Isolated BRA PACK
Features
Pressure Contact Technology
Electrically insulated base plate
Very low forward voltage drop
Very low leakage current
Planar passivated chips
International standard package
2500V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Rectifiers for UPS
Battery Chargers
Filed Supply for DC Motors
DC supply for PWM inverter
Specification
GeneSiC Part Number
MBR600100CT
Vrrm
100V
Diode Configuration
Schottky Diode Rectifier - Common Cathode
IF(av) @ 125 Deg C (50% Duty)
400 Amp per device, 200 Amp per leg
Package Size
W:20mm L:93mm D:16.5mm
Itsm
4.0 kA
VF(to)
0.84V
Tj(max)
150°C
rF
Not Published
Terminals
1/4"-20UNC
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
R th(c-h)
0.28°C/W
Weight
68g
Mounting Torque
40 Nm (40 Nm Terminals)
Factory Pack Qty
10
Certification
UL Listed, ROHS
Datasheet
Product datasheet
GIC Controls, LC33F1 4-36VAC/DC, Hours Run Meter 36VAC/DC, 48mm Round Panel Mount
Features
IP40 (IP66 with Gasket)
4-36VAC/DC
6 Digit Display
99999.9 Hours
48mm Round Panel Mount
Rectangular Cutout
UL Approved
Datasheet
Product Datasheet
M3 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V (For Non Insulated Busbar or wire)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
For Non Insulated or Insulated Busbar/ Bare Wire
Rated System Voltage 0.6/3kV (1 Min) NOTE: 30V only with Non Insulated cables, see M2 for 600V Insulated types.
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M3.10.2mA,M3.100.0.1V,M3.100.100mA,M3.100.1A,M3.100.1V,
M3.200.1A,M3.200.2V,M3.UM.1A.1V,M3.UM.50A.1V,M3.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz (customised on request)
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
Fastron Electronics GT-AV6-A-1, AC Voltage Transducer, 0-300V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV6-A-1
Control Output
4-20mA Average RMS
Input
0-300VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
M2 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 30V Bare copper, (or 600V insulated cables)
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
600V Insulation (3kv/1min) [Bare bar/wire)
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M2.10.2mA,M2.100.0.1V,M2.100.100mA,M2.100.1A,M2.100.1V,
M2.200.1A,M2.200.2V,M2.UM.1A.1V,M2.UM.50A.1V,M2.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
30V (rms) Bare Copper, 600V (rms) Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
M4 Series Current Clamp, Current Ranges from 1 Amp to 200 Amp, Clip on AC Current Clamp, Insulated to 600V for Busbar/Bare Wire
Features
Quick Release Split Core Clamp System
4mm Safety Socket Terminals
Self Powered
Rated System Voltage 0.6/3kV (1 Min)
600V Insulation (3kv/1min)
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Northern Design Part Numbers
M4.10.2mA,M4.100.0.1V,M4.100.100mA,M4.100.1A,M4.100.1V,
M4.200.1A,M4.200.2V,M4.UM.1A.1V,M4.UM.50A.1V,M4.UM.5A.1V
Technology
Split Core AC Current Clamp
Ratio
1,10,20,50,100,200 : 4mA,10mA,100mA,200mA,1A,1V,100mV
Aperture Size
15 x 17mm
Accuracy Class
Class 1 (1/10/100/200 Amp @ 5000Hz)
Isolation
600V (rms) Non-Insulated cables, 3kV (AC, 50Hz, 1 min)
Bandwidth
40-5000Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10°C / 50°C
Termination Style
Screw
Approvals
Class III per IEC1010-1
Unit Weight
200g
Factory Pack Qty
1
Datasheet
Product Catalogue
M1.100.1A Datasheet
M2.DM.100A.1VDC
M1.10A.4mA Datasheet
M3.M.10A.4mA Datasheet
M4.3D.50.100.200A-1VDC
Littlefuse-IXYS, Single Phase Diode rectifier Bridge, 50Amp, 1200V, Single Phase Diode Rectifier Bridge, 50Amp, 1200V, Replaces Semikron SKB52/12 SKB50/12 IXYS PSB55/12
Features
Package with DCB ceramic base plate
Isolation voltage 3000 V∼
Planar glass passivated chips
Low forward voltage drop
Leads suitable for PC board soldering
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Specification
IXYS Part Number
VBO50-12N07
AC Line voltage
400V
Device Configuration
Phase Diode Rectifier Bridge
DC Output @ 85 Deg C
50 Amp
Package Size
W:72mm L:60mm D:28mm
Itsm
750 A
VF(to)
0.85V
Tj(max)
150°C
rF
11mΩ
Terminals
M5 (5Nm)
Hole Centres
60mm (M5)
Gate Terminals
N/A
R th(j-c)
2.6°C/W
R th(c-h)
0.24°C/W
Weight
260g
Isolation
3kV
Factory Pack Qty
10
Certification
UL Listed
IXYS Headquarters
USA
Datasheet
Product Datasheet