Fastron TC5-W-W-2-A-2 PID Controller 100-240VAC, with 2 3 Amp Relay Alarms, 4-20mA Input, 96x48mm, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-W-W-2-A-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/ 12VDC @20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron FJTY220D80P, Single Phase Intelligent Phase or Burst Control Module with 2 second Soft Start, 4-20mA,0-10V,0-5V,10K POT Input, 220VAC, 80 Amp Per Phase, Voltage Regulator
4-20mA,0-10V, 0-5V or 10K POT Proportional Phase Control Input
Ratings from 25A to 80 Amp @ 180-280 VAC
SCR output for heavy industrial loads
Instantaneous turn-on output
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Trent part Number
FJTY220D80P
Switching Type
Phase Angle (Random Crossing)/ Burst Fire (10 cycles)
Control Voltage
4-20mA,0-10V,0-5V,10K POT Proportional Input
Load Current
80 Amp (rms)
Surge Capability
690Amp (peak)
Special Feature
Single Phase Proportional Controller + 2 Second Soft Start + Selectable Half Wave control
Mounting Style
Panel Mount
Load Voltage Range
170-220VAC +15% (253VAC Max)
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Dimensions
105 x 80 x 55mm
Unit Weight
400g
Factory Pack Qty
20
Datasheet
FJTY Series Voltage Regulators
Rishabh DS96/150A/75mV, Moving Coil Ammeter 150Amp DC for 150A/75mV Shunt Connect
Features
Adjustable Display Scaling
PC 94 UL V0
For robust Measurement
Each unit needs just 96 x 96mm Panel Space
65mm Depth
Specification
Rishabh Part Number
DS96/150A/75mV
Nominal Measurement Range
0 - 150 Amp AC
Shunt Input
0-75mV Unipolar
Maximum Measurement Range
150 Amp
Over Range
Ipn x 2
Operating Temperature
0 - 50°C
Frequency
15...100Hz
Safety Rating
IP52 case, IP20 terminals wiht back cover
Termination Style
Screw
Mounting Style
96 x 96mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
Electronicon 275.105-10120 - Discharge Resistor for 25-40KVAR Capacitors which require external resistors
Rated for 3 x 120kOhm 600VAC
Check Capacitor datasheet to see if they are included . See "Discharging" section. If no "Discharging" section they are required
Datasheet
Product Datasheet
Application Notes
Blog on Discharge Resistor Selection
Gigavac GV121CAB, Contactor SPST-NO, 200+ AMP, 12-100VDC, 24VDC Coil, 38cm Flying leads, IP67, w/SPST-NO Aux Contact
Features
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV121CAB
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
12VDC
Load Current
200+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
None
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 100VDC
Standards
CE, UL1604, IP67, SAEJ1171
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDH12048ZA1B, Solid State Relay, Contactor Style, 480VAC, 120 Amp, 90-280VAC Control, Zero Crossing, Panel Mount Power Module Style for 80mm rails
Ratings from 25A to 125 Amp @ 48-530VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Specification
Fastron Part Number
FDH12048ZA1B
Switching Type
Zero Crossing
CE
Yes
Control Voltage
90-280VAC
Load Current
120 Amp (rms)
Surge Capability
1100 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Load Voltage Range
90-480VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
105g
Factory Pack Qty
20
Datasheet
Product Datasheet
Crydom MCPC2425C, Solid Sate Relay based Phase Angle Controller,170-280VAC, 25 Amp, 0-10V Input
Features
Selectable Proportional Burst Control Input
Ratings from 25A to 90 Amp @ 180-530 VAC
SCR output for heavy industrial loads
Zero voltage turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
MCPC2425C
Switching Type
Phase Angle
ROHS/CE/UL
Yes
Control Voltage
0-10V Proportional Input Requires DC Power Supply
Load Current
25 Amp (rms)
Surge Capability
397Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
170-280VAC
Overvoltage Vpk
1200V
Termination Style
Terminal Plug & Screws
Unit Weight
87g
Factory Pack Qty
10
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Crydom PMP2450W or Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Fastron DTC1-A/M, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 4-20mA output
Optional converter function
2 Input 1 Output, and 1 Input Two Output Versions available
Optional 60 Segment Multi Pattern Program Control feature
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M
Control Output
4-20mA
Input
Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
PWM Control Wiring
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual
Fastron DTC1-A/M1, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 24VAC/DC, 4-20mA output
Optional converter function
2 Input 1 Output, and 1 Input Two Output Versions available
Optional 60 Segment Multi Pattern Program Control feature
4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response)
CE Approved
Each unit needs just 22.5mm width Din Rail space
EC Compliant (Details)
Various specials available for unique applications.
Specification
Fastron Part Number
DTC1-A/M1
Control Output
4-20mA
Input
Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100
Alarm
Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC
Options
None
Mounting Style
22.5 x 75mm Din Rail Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
230g
Factory Pack Qty
1
CE
Yes
??
Selection Chart
PWM Control Wiring
Datasheet
DTC1 Brochure
DTC1User Manual
DTC1 User Manual Comms versions
Alarm Table
DTC1 (Program Control Version) User Manual