LEM FRS 2000-SBI, O/L Coreless Current Transducer, 2000 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Bipolar Output
Features
Bandwidth DC to 1000kHz
Open loop transducer using Coreless Hall effect Technology
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
Low power consumption
Applications
Wind Turbines
Electrolyser
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications.
Specification
LEM Part Number
FRS 2000-SU
Technology
Open Loop Coreless Hall Effect
Aperture
111.4 x 18.7mm Square
ROHS
Yes
Supply Voltage
+12...24VDC, Isolated
Load Current (RMS + DC)
2000 Amp
Measurement Range
+/-6000 Amp
Overload Rating
N/A
Output
4-20mA Bipolar
Isolation
5.3 kV
Bandwidth
DC-1000 kHz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 85°C
Accuracy
1%
Termination Style
Molex 5045-04A
Unit Weight
1500g
Factory Pack Quantity
4
Â
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Â
Crydom HS072 + D1D40, DC Solid State Relay, with Panel Mount Heatsink 3-32VDC control, 36A @ 40 Deg C, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 100-500VDC
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
HS072 + D1D40
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
3.5-32VDC
Load Current @ 40 Deg C
40 Amp DC
Surge Capability (10ms)
106 Amp DC
Special Feature
None
Mounting Style
Panel Mount
Load Voltage Range
0 - 100VDC
EMC Compliant
Level 3
Termination Style
Screw
Dimensions
L:139.7 x W:100.3 x D:66.8mm
Weight
600g
Factory Pack Qty
20
Datasheet
Series 1 DC
HS072
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
See alternative D1D40K with raised terminals for alternative or D1D80 for higher current alternative
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Furison FTC048-A3C, PID Temperature Controller for HVAC, 87.6x34.5mm (71x29m Cutout), 100-240VAC, 2 x Relay Outputs (one prgrammable), 2 x NTC Inputs, 2 x Digital Inputs, Includes single NTC Sensor Only
3-digit display suit refrigeration temperatures to 1 Degree
Drip-proof / Dust-proof IP64 (front panel only)
Each unit needs just 71 x 29mm panel space
3 minute delay protection
Automatic 15 minutes ON, 30 minutes OFF on sensor failure
Overtemperature Alarm including 10 Amp Relay, Buzzer and LED Blinking
Ultra High temperature 99 - 120 Deg C Displays "HH"
Specification
Furison Part Number
FTC048-A3C
Control Output
2 x SPST Relay 10A(Resistive)for Heat/Cool/Compressor/Fan/Alarm
Input
2 x NTC Probe ( 1 only sensor Included with 2 Meter wire length)
Cooling/Cooling Outputs
2 x 230VAC 10 Amp Relay Contact
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
100-240VAC
Termination Style
Screw
Weight
150g
Factory Pack Qty
1
Certifications
UL, CE
Â
Datasheet
Download Datasheet
Risbabh EM94-Z-V3-L-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 201-1000VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60V DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 201-1000VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
Â
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Â
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
60-300VAC/DCÂ power supply
Specification
Rishabh Part Number
EM94-Z-V1-L-D
Functions
kWh Meter, Energy Meter
Supply Voltage
60-300VAC/DC
Nominal Measurement Range
201-1000VDC
Maximum Measurement Range
60-300VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YESÂ 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
Â
IP54
Â
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Â
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Â
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Â
Risbabh EM94-Z-V1-M-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input,10-60VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,10-60VAC/DC Aux Supply, Internal Logging
2 Pulse/Alarm Outputs
50-150mV Shunt Input, and nominal voltage 60-300VDC
RS 485 communication up to 57,600 bit/s
USB Port
8MB Internal Storage
DC Measurement Only
Â
The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals.
Â
Features :
96 x 96mm Panel Mount
Accuracy class 0.5
Simple Menu
RS 485 communication up to 57,600 bit/s
USB Comms
8MB Internal Logger
10-60VAC/DCÂ power supply
Specification
Rishabh Part Number
EM94-Z-V1-M-D
Functions
kWh Meter, Energy Meter
Supply Voltage
10-60VAC/DC
Nominal Measurement Range
60-300VDC
Maximum Measurement Range
60-300VDC
Display
Single Line LCD
Pulse/Relay Output
2
Accuracy
Class 0.5 (Energy)
USB
YES
Real Time Clock
1min/month (30ppm)
Isolation
3.5kV
RS485 Modbus RTU
YESÂ 57,600bps
Weight
450g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Environment
Â
IP54
Â
Safety
Protection Class II
Enclosure Material
Mablex with fire protection to UL94-V-O. Self extinguishing
EnclosureSize
96 x 96mm x 83.5mm (72mm behind panel)
Â
Terminals
Rising Cage 4mm² (12 AWG) cable max
Humidity
< 75% Non Condensing
Operating Temperature
-20 →+70 °C
Â
Datasheet
Product Datasheet
Software
Software User Manual
Software Download Link
Application Notes
1)Reading Data from Registers -> Download file
2)Maximum Memory Size -> Read below
Max Available Memory Locations in 8MB Size = 273030
Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user
Considering your example for 2 parameters:
Number of parameter selected by user = 2 (kwh & kVA)
Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log)
Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257
Timelog Interval setting = 15 minutes
Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs
Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Â
Gigavac GV200MA-1, Contactor SPST-NO, 500+ AMP, 12-800VDC, 12/24VDC PWM Coil
Features
PWM Rated Coil
Hermetically Sealed
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 - Temporary water immersion (30 Min)
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Specification
Gigavac Part Number
GV200MA-1
Main Contact Type
SPST-NO
Auxiliary Contact Type
None
Coil Voltage
12/24VDC (PWM)
Load Current
500+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.5kV rms
Control Input Terminals
38cm Flying Leads
Special Feature
PWM Rated Coil
Mounting Style
Panel Mount (M5)
Load Voltage Range
12 - 800VDC
Standards
CE, UL1604, IP67, SAEJ1171, UL508
Termination Style
M8
Unit Weight
450g
Factory Pack Qty
1
Datasheet
Product Datasheet
TRENT TGD-1PL C 25-10kA, 1 Pole Miniature Bidirectional DC Circuit Breaker C Curve 25 Amp, 10kA, 250VDC
Miniature DC Circuit Breakers are used for over current (overload and short circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
< 50mS Trip Delay Time
1 Pole Disconnect
10kA Short Circuit Rating
Suitable for Isolation
Customised versions available
Type B, C, D Curve available
BidirectionalÂ
Standards :
IEC/EN 60898
IEC/EN/AS60898-1
IP20 (IP40 Installed) IEC 61008
CE,CB,RCM (Pending)
Specification
TRENT Part Number
TGD-1PL C 25-10kA
Functions
1 Pole MCB - C Curve
Nominal Voltage
250VDC @ 50/60Hz
Nominal Current Range
25 Amps RMS
Trip Delay Time
< 50ms
Rated Impulse Voltage
6kV
Operating Temperature
-25 to 40 Deg C
Mechanical Operations
10,000 Ops
Insulation Voltage
690V
Breaking Capacity
10kA
Approvals
CE,CB, RCM (Pending)
Standards
IEC/EN/AS60898-1, IP20 (IP40 Installed) IEC 61008 ;
Weight
350g
Enclosure Material
UL94
Factory Pack Qty
1
TRENT Headquarters
Australia
Â
Datasheet
Product Datasheet
Iskra Doo SQ0214 L 100V RC S6SS, Synchroscope (Synchronoscope)
Measurement of phase difference between bus bar and generator
Five instruments in one (SQ 0x14)
Circular display of ∆ phase difference
Magnifield display of phase difference ∆ = ±20
Microprocessor processing
Simple synchronization conditions setting
Output relay for synchronisation (pulse or continuous)
''Dead busbar or generator'' functionality
Power supply from bus bar or generator
Standard 96x96 mm or 144x144 mm din housing
LCD with backlight for voltage, frequency and/or ∆ monitoring (SQ 0x14 only)
High immunity to EMC disturbances
Special functions set with three jumpers inside the instruments Status output
Green led for indication of both voltages
Ship version (Bureau veritas certificate - SQ 02x4)
Â
Specification
Iskra Doo Part Number
SQ0214 L 100V RC S6SS
Function
Phase Difference (∆ϕ) Measurement
Nominal Voltage (Un)
100VAC ± 20 % Line to Line (UL-N = 400 VMAX) @ 40-70Hz
Digital Output
Relay 250 V, 1 A, 50 Hz, 250 VA
Status Output
Open-Collector 24 Vdc + 20% @30mA
Switch On Delay Time Range
0,1 ... 1 s +/-10%
Phase Difference Setting Range
2 ... 20 °el ± 3 °el
Voltage Difference Setting Range
1 ... 10 % +/-2.5%
Dead Busbar Noise Rejection Range
10%, 20%, 30% or 40%
Power Consumption
< 4VA
Short Term Overload
2 x Un for 3 seconds
LCD Display Accuracy
Voltage 1.5%, Frequency 0.5%, Phase Difference +/-3 °el
Synchronisation Accuracy
+/- 10%
Termination Style
Screw
Weight
530g
Certification
CE
Factory Pack Qty
1
Enclosure Version
Ship Version
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP52 for case, IP20 for terminals with protective cover
Safety
According to EN 61 010-1 400 V, installation category III Pollution degree 2
Operating Temperature
-20...55 °C
Datasheet
Product Datasheet
User Manual
Application Notes & Software Downloads
The following parameters can be set via internal jumper see User Manual for more details.
Dead Busbar Generator Function
Over and Under Frequency Synchronising
Adjustable Length of a Sync Pulse
The following parameters Can be set via MIPack Comms Module & SQset Setting Software
Relay - 300mS/Continuous/Programmable
Dead Busbar - Active DB/Active DB + DG & % Threshold
Â
MIPack User Manual
Download SQSet Settign Software
Iskra IK63-31-24VAC/DC, 3 Pole 3 x SPST NO, Configuration_SPST (1 x NC), Modular Contactor 440VAC 63 Amp, 24VAC/DC Control Voltage
Features
63 Amp (rms) @ 440VAC
DIN Rail Mount
Slim package
CE Compliant to IEC 60664
IP20
Specification
Fastron Part Number
IK63-31-24VAC/DC
Switching Type
3 x SPST NO, Configuration_SPST (1 x NC)
Approvals
CE
Coil Voltage
24VAC/DC
Load Current (RMS/DC)
63 Amp (rms) @ 440VAC
Special Feature
Hum Free
Mounting Style
DIN Rail Mount
Load Voltage Range
440VAC
Isolation
4kV
Termination Style
Screw
Unit Weight
295g
Factory Pack Qty
20
Â
Datasheet
Contactor Datasheet
RCS-1800-0400 Three-Phase Flexible Current Sensor System (Rogowski Coils):
The RCS-1800 three-phase flexible rope CT from Magnelab converts AC input current of up to 5000 amperes to an AC output of 0.333 volt.
A 9 to 36 VDC power supply is required to operate these coils. The RCS-1800 comes with an integrator which includes flexible strain relief cables.
Included is an 12 inch circumference rope CT with Integrator, and 8 feet of twisted pair (600V) output leads.
Magnelab Coils come with 10 year warranty
Suitable Alternative to Solar Edge CTRC-07500-0400
Specification
Magnelab Part Number
RCS-1800-0400
Function
AC Current Measurement
Nominal Measurement Current (Ipn)
400 Amp RMS
Measurement Range
10% - 130% if Ipn
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
9 - 36VDC
Accuracy
1% from 25 to 500 Amp
Phase Angle
< 0.5 Degrees
Coil Diameter (⌀)
6 Inch
Coil Circumference
18 Inch
Integrator to Coil Cable
8 Feet Shielded
Maximum Voltage
600V (on bare conductor)
Operating Temperature
-15°C to 65°C
Storage Temperature
-45°C to 80°C
Power Consumption
< 2VA
Overload
20,000 Amp (continuous)
Termination Style
Screw
Weight
1200g
Certification
CE
Factory Pack Qty
1
Certifications
UL Recognized E96927 to IEEE C57.13, CAN/CSA 60044-1
Meets UL STD 61010-1, CAN/CSA C22.2 No. 61010
CE
ROHS
Datasheet
Product Datasheet
Application Notes
RCS/RCT Series Installation Guide
Crydom HS151DR-D1D20, Din Rail Mount DC Solid State Relay, with Heatsink 3-32VDC control, 18A @ 40 Deg C, 100VDC Load
Features
Ratings from 7A to 100 Amp @ 1-500VDC
Mosfet output for equal load sharing
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Part Number
HS151DR + D1D20
Switching Type
DC Switching
ROHS/CE/UL
Yes
Control Voltage
3.5 - 32VDC
Load Current
18 Amp DC @ 40 Deg C
Surge Capability
42 Amp DC
Special Feature
LED Status Indicator
Mounting Style
Panel Mount
Reccomended Load Voltage
1-72 VDC
Max Load Voltage
100 VDC
Termination Style
Screw Terminals
Dimensions
L:97mm x W:45mm x D:142.8mm
Unit Weight
450g
Factory Pack Qty
10
Â
Datasheet
HS151DR Datasheet
Series 1 DC
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies