H-10-2-24, Split Core Hall Effect DC Current Transducer, 0-10 Amp DC, 4-20mA unipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, 0-10 Amp DC, 4-20mA Unipolar Output
Features
⌀31mm Aperture
Split Core
DC Unipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
H-10-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
0-10 Amp
Response Time
< 200mS
Output
Unipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron Electronics FTF-240-120-160VA, Step Down Transformer, 240VAC input, 120VAC output 160VA
Features
Rugged Design
Panel Mount
Iron Core
Applications
Step Down Voltage for 110VAC/120VAC Systems
Aux Power for USA based equipment
Specification
Fastron Part Number
FTF-240-120-160VA
Technology
AC Power Transformer
Ratio
240/120
Secondary Voltage
120VAC rms
Primary Voltage
240VAC rms
Secondary Current
1.33 Amp rms
Primary Current
0.66 Amp rms
Power Rating (VA)
160VA
Bandwidth
50-60Hz
Mounting Style
Panel Mount Sides or Bottom
Operating Temperature Range
-15°C / 60°C
Unit Weight
4kg
Factory Pack Qty
1
Fastron FDV-500-V05-24, DC Voltage Transducer, Din Rail Mount, 0-500VDC, 5V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-500-V05-24
Analogue Output
5V
Input
0 - 500VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Accuracy
1%
Response Time
150mS
Voltage Isolation (1 min)
2.5kV
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-1000-V10-24, DC Voltage Transducer, Din Rail Mount, 0-1000VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-1000-V10-24
Analogue Output
0-10V
Input
0 - 1000VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron FDV-50-V10-24, DC Voltage Transducer, Din Rail Mount, 0-50VDC, 0-10V output, 24VDC Supply Voltage, 150mS Response
150mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 5V DC output (for voltage output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Part Number
FDV-50-V10-24
Analogue Output
0-10V
Input
0 - 50VDC
Measurement Range
120%
Overload
150% Continuous
Operating Temperature
-30 - 70°C
Operating Voltage
24VDC +/-15%
Voltage Isolation (1 min)
2.5kV
Accuracy
1%
Response Time
150mS
Termination Style
Screw
Mounting Style
DIN Rail Mount
Safety
CE, UL94V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics AM5H-A-DV7-A, 96x48mm Digital Voltmeter 0-600VDC with 1 x Relay Alarm, 110/240VAC Aux supply, 5 Digit
Adjustable Zero and Span Setting
Adjustable Display Scaling
Large 5 Digit 20.3mm (8 Inch) LED Display
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 96 x 48mm Panel Space
90mm Depth
Specification
Fastron Electronics Part Number
AM5H-A-DV7-A
Alarm Output
1 x Relay, 3 Amp 250VAC
Input
0 - 600VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
110/240VAC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Display Type
5 Digit RED LED
Mounting Style
96 x 48mm Panel Mount
Case Material
PC - UL 94 V0
Weight
320g
Factory Pack Qty
1
Datasheet
Product Datasheet
User Manual
Application Notes
Panel Meters Blog Articles
Fastron Electronics GT-AV(0-500)-D-1, AC Voltage Transducer, 0-500V AC input, 22-60VAC/DC aux, 4-20mA Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV(0-500)-D-1
Control Output
4-20mA Average RMS
Input
0-500VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
RODN303015, Steel Enclosure, 300mmH x300mmW x 150mmD, IP66, RAL 7035 Gray 1.5mm Galvanised Steel
Features
Injected Polyurethane Sealing gasket
3 x M20 cable glands
4pcs Wall Mounts and dynabolts included
Lockable Door via Key
RAL7035 GREY AS3000/AS3100 Compliant
IP66
Specification
Fastron Part Number
RODN303015
Function
Steel Water Proof Enclosure
Configuration
Enclosure with Hinged Door, Key Lock, 4 Mounting Clips, DYnabolts, and Cable Glands
Termination Style
Screw Mount to gear tray
Dimensions
H:300 x W:300 x D:150mm
Weight
7kg
Certification
AS 3000
AS 3100
Factory Pack Qty
1
Material of housing
1.5mm Galvanised Steel Painted RAL 7035
Enclosure protection
IP66
Operating Temperature
-20...55 °C
Datasheet
Datasheet
DCBT-300-24-10-10, Hall Effect DC Current Transducer, +/-300 Amp DC, +/-10VDC bipolar output, 24VDC supply, 20mm Aperture
Compact and versatile Split Core DC current sensor, +/-300 Amp DC, +/-10VDC Bipolar Output
Features
⌀20mm Aperture
DC Bipolar Measurement
+/-10VDC analogue output
Busbar, or panel mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
DCBT-300-24-10-10
Technology
DC Hall Effect Current Transducer with Instant Output
Yes
Supply Voltage
24VDC
Nominal Current (RMS + DC)
+/-300 Amp
Response Time
< 1uS
Output
Bipolar +/-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Aperture
20mm
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Molex 4 Pin
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
Fastron FC5-S-W-1-G-2-C, 100-240VAC PID Controller with 1 Alarm, RS485 K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-W-1-G-2-C
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/SSR 12VDC @20mA
Input
Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
1 Alarm standard
Mounting Style
48 x 48 Panel Mount
Supply Voltage
100-240VAC +/-15%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol