Fastron Electronics GT-MV(0-415)-D-1, AC Voltage Transducer, 0-415V AC input, 22-60VAC/DC aux, 4-20mA TRUE RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-MV(0-415)-D-1
Control Output
4-20mA TRUE RMS
Input
0-415VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics GT-AV7-D-4, AC Voltage Transducer, 0-600V AC input, 22-60VAC/DC aux, 0-10V Average RMS output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
GT-AV7-D-4
Control Output
0-10V Average RMS
Input
0-600VAC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F50-300, 0.333V, 300Amp measurement Split Core CT's
Features
Quick Release Split Core System
Cable Mount
0.333V Output
Self Powered
Rated System Voltage 0.60/3kV
0.9M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F50-300
Technology
Split Core AC Current Transformer
Ratio
300/0.333V
Aperture Size
ø 50 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333V (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
300Amp x 1.2
Termination Style
0.9M Flying leads
Unit Weight
300g
Factory Pack Qty
9
Datasheet
Product Datasheet
Stocked Split Core CT's Listing
Application Notes
Installation Guide
Types of Current Transformers - Blog
Cable Losses and CT's
High Accuracy or High Burden Requirements for CT's
Techsem MD110-16-223F3, Single Diode Module, 110 Amp, 1600V, 22mm Package
Features
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
2900V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Deep Cycle Operation
Rectifiers for UPS
Battery Chargers
Specification
Techsem Part Number
MD110-16-223F3
Vrrm
1600V
Diode Configuration
Single Diode Module
IF(av) @ 100 Deg C
110 Amp
Package Size
W:20mm L:93mm D:30mm
Itsm
2.6 kA
VF(to)
0.8V
Tj(max)
150°C
rF
1.74mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.27°C/W
R th(c-h)
0.20°C/W
Weight
175g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
15
Certification
UL Listed
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See VSKE91/14 for Solder Contact alternative of Contact Us for Possible Replacement for alternative part
Current Transducer, AT-DV7-D-1, AC Voltage Transducer, 600VDC, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-DV7-D-1
Control Output
4-20mA
Input
0-600VDC
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-DV6-D-1, AC Voltage Transducer, 300VDC, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-DV6-D-1
Control Output
4-20mA
Input
0-300VDC
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AV7-D-1, AC Voltage Transducer, 600V Average RMS, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AV7-D-1
Control Output
4-20mA Average RMS
Input
0-600V Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22-60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Electronicon 275.269-611500/221K02 30kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 245(+32)mm Gas Filled, 3 x 115.5uF, Requires Discharge Resistor
Characteristics and utility
30kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminum case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.269-611500/221K02 30kvar 525V 50Hz
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
95 x 245(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
30 Kvar
Capacitance
3 x 115.5uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 33 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
2.5kg
Factory Pack Quantity
25
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
H71/110M + A53TP50D Three Phase Solid State Relay 90-280VAC Control, 3 x 13Amp, 48-530VAC Load
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Specification
Crydom Part Number
H71/110M + A53TP50D
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90-280VAC
Load Current
3 x 13 Amp (rms) per Phase @ 50 Deg C
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Dimensions
L:110mm x W:100mm x D:90mm
Termination Style
Screw
Weight
650g
Factory Pack Qty
10
Datasheet
H71 Datasheet
A53TP Series
Product Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Fastron FTH12053ZD3, Solid State Relay, 3 Phase 4-32VDC Control, 120A, 70-530VAC Load 3 Phase Solid State Relays, with IP20 Cover
Ratings from 25 to 120 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
IP20 Cover Included
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Includes IP20 Cover
Specification
Fastron Part Number
FTH12053ZD3
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
120 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator, with IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
70-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent Parts
Contact Us for Possible Replacement
Fastron Electronics FWBV414H29-500AC-420, AC Voltage Transducer, 0-500V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request)
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
FWBV414H29-500AC-420
Control Output
4-20mA Average RMS
Input
0-500VAC, 50/60Hz (25Hz - 1kHz Available on Request)
Over Range
x 1.5
Operating Temperature
0 - 60°C
Load Voltage
100-240VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet