Search results for "선불유심20만원 Gora43430aa 휴대폰미납소액대출 고라통신 선불유심 현금화 정식업체 저신용자비상금소액대출 청송군 24시 당일소액급전대출"
-
KC60-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 30, 60, 80 kVar, 100,000 Operations, AC-6B
Free Aus Post Shipping for $300 SpendIskra Doo KC60-12-230-50, Capacitor Duty Contactor 240/480/600VAC @ 30, 60, 80 kVar, 100,000 Operations, AC-6B Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : Capacitor Duty Discharge Resistors Three-pole contactors Seven ratings from 12,5 kVAr to 60 kVAr IEC 60947-4-1 for AC-6b utilization category UL Approved Advantages : Conforms to utilization category AC-6b Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Switching of capacitor bank in parallel without de-rating Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 220 V 50/60 Hz, 230 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KC60-12-230-50 Functions 3 Pole Capacitor Duty Contactor Nominal Voltage 230/480/600VAC @ 50Hz Current Carrying Capacity as per UL 30kVar/Amp @230VAC, 60kVar/Amp@480VAC, 80kVar/Amp@600VAC, AC-6B Auxiliary Contacts 1 x NO and 2 x NC Trip Delay Time 2-10ms Electrical Life 100,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 16,000,000 Ops Control Voltage 230VAC Power Dissipation 5.2W Approvals UL Standards IEC/EN 60947-4-1, AS/NZ 61009-1, AC-6B Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Application Notes Discharge Resistor Usage Power Factor Correction Blog
-
CWA4890E, Solid State Relay, Single Phase 18-36VAC Control, 90A, 48-660VAC Load. High surge
Free Aus Post Shipping for $300 SpendCrydom CWA4890E, Solid State Relay, Single Phase 18-36VAC Control, 90A, 48-660VAC Load. High surge Features Ratings from 25A to 125 Amp @ 48-660VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number CWA4890E Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 24VAC (18-36VAC) Load Current 90 Amp (rms) Surge Capability 1350 Amp (peak) Special Feature LED Status Indicator, High Surge Mounting Style Panel Mount Load Voltage Range 48-660VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485
Rishabh Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z, Active Power/Reactive Power/Apparrent Power/Phase Angle/Power Factor Transducer 4 wire, 100-500V, 5Amp measurement,60-300VAC/DC Supply, 1 x 0-20mA/4-20mA/0-10V Output, with Display & RS485 Measures Active Power/Phase Angle/Power Factor Measures Apparent/Reactive/Active Power Digital output setting 0-20mA/4-20mA/0-10V Dual output version available 300mS response time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 43.75 x 100.9 mm depth DIN Rail cabinet space Specification Rishabh Part Number Rish Con P 4WUB 100-500V 1/5A 60-300U 10 D Z Functions Power/Phase Angle/Power Factor Transducer 4 wire Measurement Output 4-20mA/0-20mA/0-10V User Selectable Input 57 - 500VAC 50/60Hz Overload (Continuous) 120% Overload (1 second) 150% Operating Temperature -40 - 70°C Supply Voltage 60 - 300VAC, or 24-60VAC/DC Accuracy 0.2% Response Time 300mS Termination Style Screw Mounting Style DIN Rail Mount Safety IP40/IP20 EN60529 Protection Class II EN61010 Weight 400g Factory Pack Qty 1 Datasheet Product Datasheet Technical Support Rish Con P setup procedure blog
$379.00
$447.22 inclGST -
KNL90-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 24VAC Coil
Free Aus Post Shipping for $300 SpendIskra Doo KNL90-11-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 90 Amps, 24VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL90-11-24VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 90 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional BFX10-40, 4 Pole Snap On Aux Contacts Trip Delay Time 2-10ms Electrical Life 1,200,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 15,000,000 Ops Control Voltage 24VAC Power Dissipation 9.4W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 1.25kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
KNL250-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 250 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL250-00-24VAC Contactor Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL250-00-24VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 250 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO Trip Delay Time 2-10ms Electrical Life 1,100,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VAC Power Dissipation 24.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 9.5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation
Free Aus Post Shipping for $300 SpendLEM DVM 2000-B, Digital Voltage Transducer, Vpn = 2000V, +/-12...24VDC, 6.66V output, 12kV Isolation Features Bandwidth DC to 13kHz Digital Transducer (ASIC based) Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVM 2000-B Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/-2000V Measurement Range +/- 3000V Output 6.66V @ +/- Vpn Isolation 12 kV Bandwidth DC-13 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style M5 Screw, M5 Inserts on Input Unit Weight 375g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
G18WP-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G18WP-12VDC, HV Relay, 15kV, 30A, SPDT-CO, 12VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G18WP-12VDC Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 12VDC Load Current 30 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 17kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
DCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols, PTB Approved for Billing Purposes
Free Aus Post Shipping for $300 SpendDCBM LEM DC kWh Meter, Class B, DIN Rail Mount, 1000VDC, with 400 or 600 Amp Shunt, IP Enabled, OCMF, DHCP Protocols. PTB Germany Approved, or MID Approved for Billing 0-400/600 Amp Shunt Measurement Options (Included) Bi-Directional DC Measurement Voltage Measurement Range 150V to 1150V Backlit LCD 12VDC to 24VDC Supply Voltage Meter Operating Temperature -25°C to 70°C Sensor Operating temperature -40°C to 85°C Busbar Operating temperature 105°C max IP Enabled with DHCP 12 - 24VDC Supply Accuracy Class B The meter is intended for measuring, and monitoring DC electrical power and in particular EV charger networks. The meter records DC power according to the principle of fast sampling of voltage and current signals and is approved for billing purposes. A built-in microprocessor calculates measurands. Features : Measurement of DC kWh Power Graphic LCD with illumination Specification LEM Part Number DCBM400, DCBM600 Functions DC Energy Meter Supply Voltage 12-24VDC Nominal Measurement Range 150VDC to 1000VDC Maximum Measurement Range 150 - 1150VDC Nominal Current Input Shunt Provided IP Conficguration Fixed or DHCP Accuracy Class B Mounting Din Rail Mount Real Time Clock NTP Time Sync over HTTPS/REST Dimensions 96 x 96 x 82mm (2 DIN) Pulse Output Optional Isolation 1000VDC Reinforced (4.4kV Vrms Isolation test), PD2, OVC2, Impulse Withstand Voltage 1.2/50uS at 8kV, Altitude = 2000m Comms HTTPS/REST, Ethernet IP, OCMF/SAFE Signed Data Weight 5/6kg Certification PTB, VDE-AR-E-2418-3-100 Factory Pack Qty 1 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Operating Temperature -25 →+70°C (Meter), -40 →+85 °C (Busbar 105°C ) Datasheet Product Datasheet Leaflet
-
CV 3-1200 Digital Voltage Transducer Flux Gate, Vpn = 2828V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-1200 Digital Voltage Transducer Flux Gate, Vpn = 2828V, +/-15VDC, 10V output, 9kV Isolation Features Bandwidth DC to 800kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-1200 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 840V Measurement Range +/- 1200V Output 10V @Vp(max) Isolation 6 kV Bandwidth DC-800 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
CV 3-200 Digital Voltage Transducer Flux Gate, Vpn = 140V, +/-15VDC, 10V output, 6kV Isolation
Free Aus Post Shipping for $300 SpendLEM CV 3-200 Digital Voltage Transducer Flux Gate, Vpn = 140V, +/-15VDC, 10V output, 6kV Isolation Features Bandwidth DC to 300kHz Closed loop transducer using Flux Gate Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive High Frequency Drives AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number CV 3-200 Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 140V Measurement Range +/- 200V Output 10V @Vp(max) Isolation 6 kV Bandwidth DC-300 kHz Mounting Style Panel Mount Operating Temperature Range -25°C / 75°C Accuracy 1% Termination Style M5 Screw Unit Weight 650g Factory Pack Quantity 4 Datasheet Product Datasheet
-
VA8046, Moisture Meter for Concrete Wall. 10 Different Concrete Options. Automatic Temperature Compensation, Measurement through High Frequency Electromagnetic wave
Free Aus Post Shipping for $300 SpendVA8046, Moisture Meter for Concrete Wall. 10 Different Options. Automatic Temperature Compensation, Measurement through High Frequency Electromagnetic wave Features Portable /Battery Powered 3 x AAA For 10 Different Concrete Options Setting Upper Limit and Moisture Content Ratio Automatic Prompting of Low Voltage Prompting of Overrunning Environment Temperature -5 Deg C to 40 Deg C, Humidity 0-80% Measurement through High Frequency Electromagnetic wave Specification Datasheet Datasheet
-
ITC 2000-S/SP1 High Precision Hall Effect Current Sensor, 2000 Amp, 800mA Output, 63mm Aperture, +/-24V Supply
Free Aus Post Shipping for $300 SpendITC 2000-S/SP1 High Precision Hall Effect Current Sensor, 2000 Amp, 800mA Output, 63mm Aperture, +/-24V Supply Datasheet Product Datasheet