TGLW26-1022250, 2 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1022250, 2 Pole Rotary Switch BLACK, 250 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1022250 Functions 2 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 250Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 1.64kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
KNL250-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 250 Amps, 240VAC Coil
Heavy Item - No free ShippingIskra Doo KNL250-00-240VAC Capacitor Duty Contactor Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL250-00-240VAC Functions 3 Pole Contactor Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 250 Amp Continuous @ 55 Deg C Auxiliary Contacts 3 x NO Trip Delay Time 2-10ms Electrical Life 1,100,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 24.5W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 5kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact
Free Aus Post Shipping for $300 spendGigavac MX11BCC, DC Contactor, Milspec SPST-NO, 150 AMP, 12-48VDC, 12VDC Coil, 122cm Flying leads, IP67, IP69K, 1 x SPST-NC Auxiliary Contact Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MX11BCC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 12VDC Load Current 150 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 122cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
GX26FAC, Contactor SPST-NO, 600+ AMP, 12-800VDC, 48VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Heavy Item - No Free ShippingGigavac GX26FAC, Contactor SPST-NO, 600+ AMP, 12-800VDC, 48VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX26FAC Main Contact Type SPST-NO Auxiliary Contact Type SPST-NC Coil Voltage 48VDC Load Current 600+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 580g Factory Pack Qty 1 Datasheet Product Datasheet
-
MXNC14CA, Contactor Military Grade SPST-NC, 400 AMP, 12-48VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69K
Free Aus Post Shipping for $300 spendGigavac MXNC14CA, Contactor Military Grade SPST-NC, 400 AMP, 12-48VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69K Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K Milspec MIL-R-6106 ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number MXNC14CA Main Contact Type SPST-NC Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 400 Amp Mechanical Life @ 0 Amp 300,000 Cycles Dielectric at Sea Level (leakage <1mA) 1.5kV rms Control Input Terminals 38cm Flying Leads Aux Contact Terminals N/A Special Feature Hermetically Sealed rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-48VDC Standards MIL-R-6106, IP67, IP69K, ROHS Termination Style M8 Unit Weight 500g Factory Pack Qty 1 Datasheet Product Datasheet
-
DK 100 C10, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-10V unipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 100 C10, Hall Effect DC Current Transducer, 50, 75, 100A DC, 0-10V unipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 50, 75, 100 Amp DC. Choice of output types: 0-20mA, 4-20 mA, 0-5 V or 0-10 V Features ⌀19.1mm Aperture DC Unipolar Measurement 0-10V voltage output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 100 C10 Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-50VDC Nominal Current (RMS + DC) 50,75,100 Amp Selectable Response Time < 100ms Output 0-10V Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
VX2-UCMD-A2CTD4H2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input, Current Feedback
VX2-UCMD-A2CTD4H2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 2 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input, Current Feedback Multirange Input (Programmable) 4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) Drip-proof / Dust-proof IP65 (front panel only) UL/CE Approved Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 60 mm depth panel space EC Compliant Specification Hanyoung Nux Part Number VX2-UCMD-A2CTD4H2R Control Output 1 (Heat) 4-20mA Control Output 2 (Cool) Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals. Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 2 x Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 2 Event Input (2x SV), 4-20mA Remote Setting Input, Retransmission, Current Feedback Mounting Style 48 x 96mm Panel Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 350g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet VX Series Brochure VX Series Instruction Manual Free Software Hanyoung Nux TCS Software Hanyoung Nux TCS Software User Manual USB Driver (Windows 7) Not required for Windows 10 or 11
$271.00
$319.78 inclGST -
DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved
Eastron Europe DCM230 2-4-1-1 V1, DIN Rail Mount DC kWh Meter, 5-60VDC, 85-265VAC aux, Class 1, 45/60/75mV Shunt Connect, w/ 1 x pulse outputs and RS485 Modbus RTU Comms, Single Tariff, MID Approved 45/60/75mV Shunt Connect RS 485 communication up to 38,400 bit/s as standard 1 x Pulse Outputs (1 Configurable) Bidirectional Measurement The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records DC Current and Voltage (DC Power) value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, energy, power) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number DCM230 2-4-1-1 V1 Functions DC Energy Meter Supply Voltage 9-60VDC Nominal Measurement Range 5-60VDC Maximum Measurement Range 5-60VDC Nominal Current Input Shunt up to 2000Amp See our DC Current Shunt Section for Suitable Shunt Pulse Output 1 x Configurable 60/100/200ms Tariff Input N/A Accuracy Class 1 (I,U,kW,kWh) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 36mm x 100mm x 66mm (2 modules wide) Isolation 4kV RS485 2400-38400 b/s Weight 250g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Utility EEM Meter Setting Software Utility
$249.00
$293.82 inclGST -
AKR 200 B420L, Split Core AC Current Sensor, selectable 100, 150, 200 Amp, True RMS Average RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR 200 B420L Series True RMS Split Core AC Current Sensor with Process Outputs Compact and versatile Split Core AC current sensor, selectable 100, 150, 200 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AKR 200 B420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 100,150,200 Amp Selectable Maximum Measurement Current (Peak) 120,180,240 Amp Output 4-20mA True RMS Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator
Free Aus Post Shipping for $300 SpendCrydom D53TP25D, Solid State Relay, 3 Phase 4-32VDC Control, 25A, 48-530VAC Load, LED Status Indicator Features Ratings from 25A to 50 Amp @ 70-480 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Approved IP20 Cover Available AC & DC control types Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number D53TP25D Switching Type Zero Crossing ROHS/CE/UL Yes Control Voltage 4-32VDC Load Current 25 Amp (rms) per Phase Surge Capability 239 Amp (peak) Special Feature LED Status Indicator Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 315g Factory Pack Qty 10 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
LTC 600-S/SP2, C/L Hall Effect Current Sensor, 600 Amp, 200mA Output, +/-15..24V, Panel Mount, ø42mm, X = 0.7%
Free Aus Post Shipping for $300 SpendLEM LTC 600-S/SP2 Open Loop AC/DC Hall Effect Sensor Features Bipolar and insulated current measurement up tp 1500 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Railway Equipment Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Traction Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LTC 600-S/SP2 Technology Closed Loop Hall Effect Aperture ø42mm ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 600 Amp Measurement Range +/- 1500 Amp Output 200 mA Isolation 13.4 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.7% Termination Style Faston 45° 6.3 x 0.8mm and M5 threaded studs Unit Weight 750g Factory Pack Quantity 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition Accessories For Feet Kit or Busbar Kit see datasheet or LEM accessories for more details
-
HD48125, Solid State Relay, Single Phase 3-32VDC Control, 125A, 48-530VAC Load
Free Aus Post Shipping for $300 SpendCrydom HD48125, Solid State Relay, Single Phase 3-32VDC Control, 125A, 48-530VAC Load Features Ratings from 25A to 125 Amp @ 48-480VAC SCR output for heavy industrial loads Zero voltage or instantaneous turn-on outputs UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers AC & DC control types Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number HD48125 Switching Type Zero Crossing ROHS Yes (Details) Control Voltage 3-32VDC Load Current 125 Amp (rms) Surge Capability 1670 Amp (peak) Special Feature None Mounting Style Panel Mount Load Voltage Range 48-530VAC EMC Compliant Level 3 Termination Style Screw Unit Weight 75g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies