Search results for "텔레@UPCOIN24*"
-
DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation
LEM DVL 150 UI, Digital Voltage Transducer 150V Input, 4-20mA output, +/- 15V…24VDC, 8.5kV Isolation Features Bandwidth DC to 14kHz Multi Range through pin selection Closed loop transducer using Hall effect Compact and versatile Panel Mount Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference Voltage overload capability Low power consumption Applications Railway substation or locomotive AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Water Treatment Electronics Specification LEM Part Number DVL 150 UI Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/-15..24 VDC Bipolar, Isolated Primary Nominal Voltage (RMS + DC) +/- 150V Measurement Range +/- 225V Output 4 - 20mA Isolation 8.5 kV Bandwidth DC-14 kHz Mounting Style Panel Mount Operating Temperature Range -40°C / 70°C Accuracy 1% Termination Style M5 Screw Unit Weight 270g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$661.00
$779.98 inclGST -
Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 100kvar 400VAC L-L, 100kVar Smart Capacitor Bank for Plug and Play Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 3 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 100kvar 400VAC Function Reactive Power Correction Steps 4 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Steps 4 x 25kvar Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-10 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-10A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-010-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-10 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
N2083QK080, Thyristor(SCR) PUK 1412 Amp, 800V, 58/14, Replaces T1258N04TOF or T1410N06T
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N2083QK080, Thyristor(SCR) Capsule 1412 Amp, 800V, 58/14, Replaces T1258N04TOF or T1410N06T. Features Very low forward voltage drop Very low leakage current International standard package 58/14 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode-IXYS Part Number N2083QK080 Vrrm 800V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 84 Deg C 1412 Amp Package Size ø58 x 14mm Itsm 22 kA VF(to) 0.955V Tj(max) 125°C rF 0.177mΩ Gate Terminals Faston R th(j-k) (double sided cooled 180°sin) 0.018°C/W R th(c-h) (double sided cooled) Weight 200g Clamping Force 16 - 20kN Factory Pack Qty 6 Certification ROHS Westcode Headquarters UK Datasheet Product Datasheet Alternatives Contact Us for Possible Replacement IXYS replacement W2058LC060 Heatsink Heatsink Profiles
-
SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR
Free Aus Post Shipping for $300 SpendCrydom SSC1000-25-12, 8-16VDC Input, 1kV, 25Amp DC Output SSR Features Ratings from 20 Amp @ 1-1000VDC Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Improved SEMS screw and washer Redesigned housing with anti-rotation barriers Direct bond copper substrate EMC compliant to Level 3 Direct power lead frame Epoxy free design Spec Crydom Part Number SSC1000-25-12 Switching Type DC Load ROHS Yes (Details) Control Voltage 8-16VDC Load Current 25 Amp DC Surge Capability (10ms) 75 Amp DC Special Feature None Mounting Style Panel Mount Load Voltage Range 0 - 1000VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 82g Factory Pack Qty 20 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
11.131.006 AZJ3353 MAHLE - Letrika(Iskra) Starter Motor, 24VDC, 4kW (MS360) (IS1002)
Heavy Item - No Free ShippingISKRA LETRIKA (MAHLE) 11.131.006 AZJ3353 (AZJ3223) (11130676) MAHLE - Letrika(Iskra) Starter Motor, 24VDC, 4kW (MS360) (IS1002) We recommend using the Reduction Gear version IS1081 Specification ISKRA (MAHLE) Part Number 11.131.006 AZJ3353 ISKRA/LETRIKA/MAHLE 11131006 AZJ3353 MS360 IS1002 Voltage 24VDC Power 4kW No of Pinon Teeth 10 Module 3mm Unit Weight 14.8kg Factory Pack Qty 1 Applications Manufacturer Vehicle Type Engine Ltr Date HATZ 2L41 C 2L41C 2L41; 2-cyl; Stage V; 24kW 1.7 - HATZ 2M41 2M41; 2-cyl 1.7 - HATZ 3L41 C 3L41C 3L41; 3-cyl; Stage V; 37kW 2.6 - HATZ 3M41 3M41; 3-cyl 2.6 - HATZ 3M43 3M43; 3-cyl; EGR/DPF 2.6 - HATZ 4M41 4M41; 4-cyl 3.4 - HATZ 4M42 4M41; 4-cyl; EGR 3.4 - HATZ 4M43 4M43; 4-cyl; EGR/DPF 3.4 - HATZ M - Series 2-4L/M41 - HATZ M - Series 2M41 2-Cyl 1.7 - HATZ M - Series 3M41 3-Cyl 2.6 - HATZ M - Series 3M43-EGR/DPF 3-Cyl 2.6 - HATZ M - Series 4M41 4-cyl 3.4 - HATZ M - Series 4M42-EGR 4-cyl 3.4 - HATZ M - Series 4M43-EGR/DFP 4-cyl 3.4 - HATZ SILENT PACK 2L41C 2M41; 2-cyl 1.7 - HATZ SILENT PACK 2L41C 2M41; 2-cyl; EPA 1.7 - HATZ SILENT PACK 3L41C 3M41, 3-cyl 2.6 - HATZ SILENT PACK 4L41C 4M41, 4-cyl 3.4 - HATZ SILENT PACK 4L42C 4M42, 4-cyl 3.4 - Cross Reference Manufacturer Manufacturer P/N CARGO 113356 LESTER 18547 LUCAS LRS01945 MAGNETON 9172 780 MINSK TRACTORS (BELARUS) 2007 3708 000 WILSON 91-23-6506 MAHLE -> MAHLE Letrika P/N OEM P/N MAHLE P/N IS1002 11.131.006 AZJ3353 24V 4,0kW MS 360 Available IS1002 11.130.676 AZJ3223 24V 4,0kW Superseded unit, see available P/N IS1002 Spare Parts Pos. Letrika P/N MAHLE P/N Description 1 16.283.287 MSX 1266 Drive end bracket 2 15.120.243 MSX 684 Bearing 3 16.281.299 MSX 379 Central cover 4 16.905.159 MSX 357 Switch 6 16.902.098 MSX 415 Pinion with clutch 7 16.905.853 MSX 370 Lever 9 16.361.529 MSX 846 Armature 10 15.120.155 MSX 697 Bearing 11 16.908.360 MSX 828 Fixing set 12 16.906.637 MSX 803 Stator 13 16.906.638 MSX 388 Brush holder 14 16.906.639 MSX 389 Set of brushes 15 16.905.689 MSX 1328 Rear-end bracket
-
Smart ONE 75kvar 400VAC L-L, 75kVar Smart Capacitor Bank for Reactive Power Correction, IP21
Free Aus Post Shipping for $300 SpendFastron Electronics Smart ONE 75kvar 400VAC L-L, 75kVar Smart Capacitor Bank for Reactive Power Correction, IP21 For Automatic Switching of Power Factor Correction Capacitors according to changing site conditions. Features Automatic Power Factor Correction up to Cos φ = 0.95 Auto rotation of same capacitors for long life Overtemperature Alarm Optional RS485 Comms IEC 654-1, UL Approved 5 Year Fastron Electronics Warranty PR-14D.12, Automatic Reactive Power Controller 1 CT Sensing Automatic Power Factor Correction Automatic C/K Ratio Setting (0.05 -> 0.95) Cos ϕ Setting 0.85 to 0.95 CAP Backlit LCD Display Various Program Combinations IP41 Measurement System - Automatic/Manual 230VAC Aux Supply Optional Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio 2 x 10Kvar, 1 x 5Kvar Caps Specification Fastron Electronics Part Number Smart ONE 75kvar 400VAC Function Reactive Power Correction Steps 2 x 12.5kvar, 2 x 25kvar Dimensions W:475mm x D:215mm x L:610mm Nominal Voltage (Un) 110-440VAC Line to Line Supply Voltage 11-300VAC (L-N), 15VA 45-65Hz Relay Rating 250VAC/5Amp Switch Delay Time 1 - 999s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 1 - 999s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays Up to 4 Smallest Capacitor Current (0.002 - 2A) x CT ratio CT Input Range 0 - 6 Amp, or 0-1.2Amp (three CT) LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Comms RS485 (Optional) Termination Style Screw Weight 15kg Certification IEC 654-1, UL Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0, & Stainless Steel Painted RAL 1013 Enclosure protection IP21 Safety According to EN 61 010-1, installation category III Pollution degree 2 Operating Temperature -20...55 °C Datasheet Product Datasheet Controller user Manual Installation Guide MSDS for Vishay PhMKPg Series Capacitors
-
G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet
-
T1190N16TOF VT, Thyristor(SCR) PUK 1190 Amp, 1600V, 74/26
Free Aus Post Shipping for $300 SpendInfineon T1190N16TOF VT, Thyristor(SCR) PUK/Capsule1190 Amp, 1600V, 74/26 Features Very low forward voltage drop Very low leakage current International standard package 74/26 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Controlled Rectifiers AC Switch Field Supply for DC Motors Water Cooled Rectifiers Phase Controlllers Power Factor Correction Specification Infineon Part Number T1190N16TOF VT Vrrm 1600V Diode Configuration Diode Capsule (PUK) IF(av) @ 85 Deg C 1190 Amp Package Size ø74 x 26mm Itsm 25.5 kA VF(to) 0.9V Tj(max) 180°C rF 0.19mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-c) (double sided cooled 180°sin) 0.023°C/W R th(c-h) (double sided cooled) 0.0035°C/W Weight 520g Clamping Force 16 - 32kN Factory Pack Qty 12 Certification ROHS Infineon Headquarters Germany Datasheet Product Datasheet Alternatives B1815NC160 Heatsink Heatsink Profiles
-
ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D70-SP6 + AI-PMUL - 3Pcs, 3 Phase Rogowski Coil Set, Class 1, User Selectable 0.333v, 0.166v, True RMS 4-20mA, 0-20mA, 0-10V, 0-5V Outputs, Sensitivity, and Measurement Range, 7cm Diameter, SP6 = 6M Cable The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V. 2 selectable instantaneous output signals: 225 mV, 333 mV. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Included Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D70-SP6 + AI-PMUL - 3Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon) Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 7cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 3M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-PMUL Datasheet ART Series Datasheet Applicaton Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
RER02P5BX, MiniTactor Contactor, 1000VDC, 25Amp, SPST-NO, 24VDC Coil, 500,000 Cycles, 3kV Isolation, M4 Load, M3 Coil
Free Aus Post Shipping for $300 SpendRincon Power RER02P5BX, MiniTactor Contactor, 1000VDC, 25Amp, SPST-NO, 24VDC Coil, 500,000 Cycles, 3kV Isolation, M4 Load, M3 Coil Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24DC options Ideal for battery powered systems or where low power is needed Small and lightweight Flexible package for installation Specification Rincon Power Part Number RER02P5BX Main Contact Type SPST-NO Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 20A @ 85°C Mechanical Life @ 0 Amp 500,000 Operations Impulse Withstand 3kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1000VDC Standards See datasheet Termination Style M4 Screw Unit Weight 135g Factory Pack Qty 1 Datasheet Product Datasheet
-
E500M-1052, IEC 61850 SCADA Communication Module for Secure, Elite 500 Series
Elite E500M-1052, IEC 61850 SCADA Communication Module for Secure, Elite 500 Series The meter is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Elite 500 Features : Measurement of instantaneous values and accumulated energy. Includes Harmonics to the 31st Accuracy class to 0.2S Dual Internal Loggers Measurement of 20 minimal and maximal values in different time periods RS 232/RS 485 communication up to 38400 bit/s or Ethernet communication MODBUS communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs Universal or AC power supply Graphic Colour TFT 320 x 240 pixels (53x70mm) Automatic range of nominal current up to 6 A and nominal voltage up to 500 V Multilingual support User-friendly Free ECon Configuration software
$1,415.00
$1,669.70 inclGST