Search results for "텔레@UPCOIN24*"
-
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-400-010-24, Hall Effect DC Current Transducer, +/-400 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-400-010-24, Hall Effect DC Current Transducer, +/-400 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-400 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-400A ~+/-400A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-400-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-400 Amp Response Time < 1uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Molex 4 Pin Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-020-420-24, DC Current Transducer, 0-20 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-020-420-24, DC Current Transducer, 0-20 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-20 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-20mA ~0-20A AC) 10uS Response (0-0-20A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-020-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-20 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-200-010-24, Hall Effect DC Current Transducer, +/-200 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-200-010-24, Hall Effect DC Current Transducer, +/-200 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-200 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-200A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-200-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-200 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-20-420-1.0, Hall Effect DC Current Transducer, 0-20 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-20 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-20-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-20 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-25 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-25-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-25 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 25Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
11.203.645 AAK5732 MAHLE - Letrika(Iskra) Alternator, 14VDC 120Amp
Heavy Item - No Free ShippingISKRA LETRIKA AAK4569 11.203.645 AAK5732 MAHLE - Alternator, 14VDC 120Amp OEM MAHLE(Letrika) 11.203.645 (MG 119) Letrika IA1588 MAHLE LETRIKA (ISKRA) IA1588, 11203645, AAK5732, MG119 SAME (DEUTZ- FAHR GROUP) 294397340 Specification ISKRA (MAHLE) Part Number 11.203.645 AAK5732 ISKRA/LETRIKA/MAHLE 11203645 AAK5732 IA1588 MG 119 Voltage 14VDC Current 120 Amp No of Pinon Teeth 9 Special feature Dust Proof Unit Weight 5.6kg Factory Pack Qty 1 Applications MAKE MODEL TYPE ENGINE POWER YEARS DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE HD5090.4 FAR (SDF) 65kW 4-Cyl; Tier 4 3.8 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE HD5105.4 FAR(SDF) 75kW 4-Cyl; Tier 4 3.8 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE HD5115.4 FAR(SDF) 80kW 4-Cyl; Tier 4 3.8 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE LD5080 55kW 3-Cyl; Tier 4 2.9 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE LD5090 65kW 3-Cyl; Tier 4 2.9 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE LD5100 71kW 3-Cyl; Tier 4 2.9 - DEUTZ-FAHR (SAME DEUTZ-FAHR GR.) 5G SERIE MD5100 71kW 4-Cyl; Tier 4 3.8 - SAME (DEUTZ- FAHR GROUP) EXPLORER 4 105.4 SDF KD475TA; 75kW; Tier 4 3.8 2015.01- SAME (DEUTZ- FAHR GROUP) TRACTORS Different Same - Spare Parts Spare Parts List
-
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-010-24, Hall Effect DC Current Transducer, +/-30 Amp , +/-10V Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar +/-10V Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
ACD15AR/M Servo Motor Controller, 96x96mm, 100-240VAC
Free Aus Post Shipping for $300 SpendShinko ACD15AR/M Series Digital Indicating Servo Controllers • Program control, converter function are standard features • 5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response) • Drip-proof / Dust-proof IP66 (front panel only) • 9-step pattern (for SV and time) is a standard feature • UL/CSA Approved • Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) • Each unit needs just 60 mm depth panel space • EC Compliant (Details) Specification Shinko Part Number ACD15AR/M Control Output 4 - 20mA Input Multirange (refer to datasheet) Alarm 2 x Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Option 1 None Mounting Style 96 x 96mm Panel Mount Supply Voltage 100 - 240VAC Termination Style Screw Weight 330g Factory Pack Qty 1 ROHS Yes UL Yes CE Yes Datasheet ACD Series Brochure ACD Series Instruction Manual ACD Series RS485 Comms Instruction Manual Delivery 3-4 weeks delivery if not in stock
-
PFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux
Free Aus Post Shipping for $300 SpendPFC 08-8-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 96x96mm with RTC, 8 Step, 30-550V 50/60HZ, 240VAC Aux Single 1/5A CT Sensing Automatic Step Sensing (After start up sequence) Isolated Switching of Power Factor Correction Contactors Cos ϕ Setting 0.85 to 0.95 CAP Auto CT Secondary Selection Backlit LCD Display Various Program Combinations IP41 Up to 12 steps Measurement System - Automatic/Manual 240VAC Aux Supply Modbus RS485 Configurable Alarms Dual Password Protection Programmable Fan Control Programmable 1A/5A CT Ratio Specification Rishabh Part Number PFC 08-8-R-RTC Function Reactive Power Correction Nominal Voltage (Un) 110-480VAC Line to Line Supply Voltage 240VAC (L-N), 15VA 40-70Hz +/-10% Relay Rating 250VAC/10Amp Panel Size 96 x 96mm Switch Delay Time 10s - 1800s User Adjustable Alarm 1 x Relay as above Temperature Alarm 1 x Relay as above Re-connection Delay Time 10 - 1800s User Adjustable Desired Power Factor 0.80 IND - 0.80 CAP Number of Output Relays 9 Smallest Capacitor Current 10mA CT Input Range 1/5 Amp LCD Display Accuracy Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1 Phase Angle Error +/- 1% at I > 3% of range Panel Size 96x96mm Panel Mount Comms RS485 Termination Style Screw Weight 700g Certification IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water) Factory Pack Qty 1 Material of housing PC/ABS Unflammable, according to UL 94 V-0 Enclosure protection IP50 for case, IP20 for terminals Safety According to IEC 61010-1-2010, installation category III Pollution degree 2 Operating Temperature -20...60 °C Datasheet Product Datasheet User Manual Application Notes Discharge Resistor Usage Power Factor Correction Blog Quick Start Guide(Blog)
-
N2154JK060, Thyristor(SCR) PUK 1562 Amp, 600V, 41/14
N2154JK060, Thyristor(SCR) PUK 1562 Amp, 600V, 41/14 Capsule Features Very low forward voltage drop Very low leakage current International standard package 41/14 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Controlled Rectifiers AC Switch Battery Chargers Phase Controllers Water Cooled AC switches Power Factor Correction Specification Wescode Part Number N2154JK060 Vrrm 600V SCR Configuration Thyristor(SCR) Capsule PUK IF(av) @ 85 Deg C 1562 Amp Package Size ø41 x 14mm Itsm 22.7 kA VF(to) .89V Tj(max) 125°C rF 0.107mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-k) (double sided cooled 180°sin) 0.027°C/W R th(c-h) (double sided cooled) NA Weight 135g Clamping Force 10-20kN Factory Pack Qty 12 Certification ROHS IXYS-Westcode Headquarters USA Datasheet Product Datasheet Alternatives Replaces T1080N06T Contact Us for other Possible Replacements Heatsink Heatsink Profiles
$345.00
$407.10 inclGST -
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms
SDM630MCT-LORAWAN-MID-AU915, DIN Rail Mount kWh Meter, 3 Phase, 240VAC aux, Class 1, 1/5 Amp CT Connect, w/ 2 x pulse outputs and LoRaWaN AU915 Wireless Comms 1/5 Amp CT Input LoRaWaN AU915 Optional Mbus Model available True RMS values of currents and voltages 1 x Configurable Pule Output (via Display Menu or Modbus) 1 x Fixed Pulse Output (1000imp/kwh) The meter is intended for measuring, and monitoring single-phase or 3 phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals. Features : Accuracy class 1 Measurement of Active and Reactive Power Modbus RTU communication up to 38,400 bit/s communication Pulse output as standard Graphic LCD with illumination Specification Eastron Europe Part Number SDM630MCT-LORAWAN-MID-AU915 Functions Three Phase Energy Meter Supply Voltage 230V L-N +/-15% < 5VA Nominal Measurement Range 415V L-L 230V L-N, 1/5 Amp +/-15% Maximum Measurement Range 480V L-L 230V L-N, 1/5 Amp Nominal CT Current Input 1/5 Amp Pulse Output 2 x Passive, (1 x Configurable 60/100/200ms) Tariff Input N/A Accuracy Class 1 (I,U,F,kW,kWh) Class 2 (Reactive) Mounting Din Rail Real Time Clock 1min/month (30ppm) Internal Memory N/A Dimensions 72mm x 100mm x 66mm (4 modules wide) Isolation 4kV Comms LoRaWaN AS915 Weight 150g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Safety IP51(Indoor) Enclosure Material Noryl with fire protection to UL94-V-O. Self extinguishing Enclosure Size DIN 42880 4 Modules Operating Temperature -20 →+70 °C Documents Product Datasheet User Manual Modbus Protocol Setup Video - CT Ratio Unlock Modbus Utility EEM Meter Setting Software Utility
$339.00
$400.02 inclGST