Gigavac PNC113CDA, Normally Closed DC Contactor SPST-NC, 50 AMP, 1200VDC, 24VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Features
Perfect for Capacitor Discharge or Dump Switch Applications
Hermetically Sealed (Patented) rated to 175 Deg C
High Efficiency Dual DC Coils - 12,24,48VDC options
Ideal for battery powered systems or where low power is needed
Built in Coils suppression for all DC Coils
Small and lightweight
Flexible package for installation
CE Approved
Specification
Gigavac Part Number
PNC113CDA
Main Contact Type
SPST-NC
Auxiliary Contact Type
N/A
Coil Voltage
24VDC
Load Current
50 Amp
Mechanical Life @ 0 Amp
50,000 Operations
Impulse Withstand
6kV rms
Control Input Terminals
M3 Screw
Special Feature
N/A
Mounting Style
Panel Mount (M4)
Load Voltage Range
1500VDC
Standards
CE Approved
Termination Style
M4 Screw
Unit Weight
135g
Factory Pack Qty
1
Datasheet
Product Datasheet
Oztherm F431 Series 3 Phase SCR Burst Controller Spare Card Set
100% Australian Made
3 Phase Burst Controller
4-20mA, 0-5V, 0-10V or POT input Proportional Phase Control
Fully enclosed IP20
Burst Fired switching
Aluminium Frame
Removable perspex Cover
Applications
Electrical Ovens, Kilns, or Furnaces
Secondary or Direct Control only
Controlled Power Applications
Electric Boilers
Smelting of Raw Metals
Suitable for extreme environments such as mining
Room/Chamber heating
Available Options
Current Limit and Trip AC (C)
Power Limit (PW)
Phase Loss Output (PH)
Partial Load Failure (PLF)
Loose Semiconductor Fuses (F)
Internal Semiconductor Fuses (FI)
Thermal Overlad Protection (T)
Special Features
Contact Us for Possible Replacement for customised features
Specification
Oztherm Part Number
F431 Series 3 Phase Burst Controller (Cards Only)
Rated Operationg Temperature
50°C
SCR Configuration
3 Phase AC Swtich
Control Voltage
4-20mA, 0-5V, 0-10V, 10K POT (4-20mA default calibration)
Load Current
30 - 120Amps Per Phase
Control Range
0-100%
Special Feature
(Optional) Current Limit & Trip AC, Power Limit, Phase Loss Alarm, Partial Load Failure Alarm, Thermal Overload Protection, Fuses
Mounting Style
Panel Mount
Supply Voltage Range
380-440VAC +/-10%
Soft Start
1-20mS
Termination Style
Screw
Unit Weight
up to 3kg
Factory Pack Qty
1
Datasheet
F431 Brochure
F431 Installation and Commissioning Manual
Fastron FRW8-01, Temperature Control Relay, Heat/Cool, 24 - 240VAC/DC, Din Rail Mount, 1 x SPST 16 Amp Relay, Includes PTC Probe for -15 to 45 Deg C Range
Features :
Range -15°C to 45°C
Multi-voltage 24 →240 V AC/DC
LED status indicator
Heating or Cooling ON/OFF Control With Hysteresis
Specification
Fastron Part Number
FRW8-01
Function
Temperature Control Relay
Nominal Voltage
24 → 240 V AC/DC
Digital Output
1 x SPST, 250VAC/DC @ 16 Amp
Sensor Type
PTS-N-3.0M PTC Sensor
Min Breaking Current
10mA/12VDC
Temp Control Ranges
-15°C to 45°C
Repeatability
0.5%
Isolation
4kV
Repetition Accuracy
0.5%
Termination Style
Screw
Weight
80g
Factory Pack Qty
1
Certification
CE
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
Fastron FRTD-6-3-2000-2000 Resistance Temperature Detectors (RTD's)
Class A Accuracy
CE, ANSI, ROHS
Pt100 output 4 wire
Teflon Cable
Low Long Term Drift
Rated for -50 to 350 Deg C Max
2000 x 3mm (6 x 50mm Tip)
MIMS
Specification
Fastron Part Number
FRTD-6-3-2000-2000
Sensor Type
RTD - Resistance Temperature Detectors
No of Wires
4
Shaft Length
2000mm
Shaft Thickness
3mm (6mm Tip)
Approvals
CE, ANSI, ROHS
Accuracy
Class A
Cable length
2 Meter
Cable Type
Teflon/Screened/Teflon
Maximum Temperature
-50 to 350 Deg C
Special Feature
Spring Cable Strain Relief
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
800g
Factory Pack Qty
1
Datasheet
Datasheet
Xmer CT Split 125/50SC 800/5 Class 1 10VA, 55 x 85mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 125/50SC 800/5 Class 1 10VA
Technology
Split Core AC Current Transformer
Ratio
800/5
Aperture Size
55 x 85mm
VA Rating
10VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
600Amp x 1.2
Termination Style
Screw
Unit Weight
1.25kg
Factory Pack Qty
9
Datasheet
Product Datasheet
Crydom A53TP50D + KS300, Solid State Relay, 3 Phase 90-280VAC Control, 50A, 48-530VAC Load, LED Status Indicator + Cover
Features
Ratings from 25A to 50 Amp @ 70-480 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
A53TP50D + KS300
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
90 - 280VAC
Load Current
50 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator + IP20 Cover
Mounting Style
Panel Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
Product Datasheet
Equivalent
Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
LEM ART-B22-D300-SP4 + AI-PMUL - 3 Pcs, 3 Phase Rogowski Coils & Universal Multi Range Integrator with Signal Conditioner
The universal Rogowski coil integrator AI-PMUL complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-PMUL is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation.
Input signal
Accuracy Class 1 (IEC 61869-2) [1].
Linearity error ≤ 0.10 %. Protection degree IP2X.
35 mm DIN rail mounted.
Push-in terminals.
4 selectable true RMS output signals: 0…20 mA, 4…20 mA, 0…5 V, 0…10 V.
2 selectable instantaneous output signals: 225 mV, 333 mV.
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz.
12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A.
Ambient operating temperature −25...+70 °C.
Advantages
Compact design for DIN rail assembly
High accuracy Class 1 (IEC 61869-2)
Setup by user via Select / Edit buttons
Clear status indication via bi-color led
Applications
MV/LV substations on LV side: Transformer Condition Monitoring
Power metering: current measurement for active power calculation
Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation
Power quality monitoring: electrical loads and distribution system equipment
Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault
Remote Terminal Units (RTU)
Phasor Measurement Units (PMU)
Standards
IEC 61010-1: 2010
UL
EMC: IEC 61326-1:2012
Options
Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply.
Specification
LEM Part Number
ART-B22-D300-SP4 + AI-PMUL - 3 Pcs
Function
3 Phase AC Current Measurement
Measuring Range
Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp
Sensitivity
Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz
Output
Selectable; Signal Conditioned True RMS 0-20mA, True RMS 4-20mA, True RMS 5V, True RMS 10V or 225mV, 333mV Direct Output (1 Amp output coming soon)
Frequency Measuring Range
50-1500Hz (15th Harmonic)
Operating Voltage
10-32VDC
Accuracy
1% from 25 to 5000 Amp
Current Consumption
100mA (max)
Dimensions
100mm x 78mm x 15mm (Integrator), 30cm Diameter (Coils)
Mounting
Din Rail Mount
Integrator to Coil cable
4.5M Twisted and Screened
Integrator to Meter cable
User Supplied Shielded cable 1.5mm sqr, up to 6m long
Operating Temperature
-25°C - 70°C
Storage Temperature
-45°C to 80°C
Isolation (50Hz, 1 min)
1.5kV
True RMS Response Time
160-190ms
Termination Style
Push-in for 1.5mm sqr wire
Weight
58g
Factory Pack Qty
1
Certifications
UL, ROHS
Datasheet
AI-PMUL Datasheet
ART Series Datasheet
Application Notes
User Notice
1) The Rogowski coil can measure any primary current as there is no saturation effect.
2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts)
3) Frequency bandwidth and phase shift modelling schematic can be provided on request.
4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer)
5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil.
6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
TPR-3SL040H, SCR Phase/Burst Controller FANLESS, 400VAC 3 Wire (400V L-L, 230V L-N), 3 Phase, 1-5V/4-20/0-20mA/10K POT Input, with In built Fuses, 32 Amps per Phase @ 50 Deg C
Features
Phase Angle, Distributed Burst, and Time Proportional Burst Control Functions
3 Phase, or Single Phase, Angle/Burst Controller
4-20mA/1-5V/10K POT Input Proportional Control
Fully enclosed IP20
Phase Angle or Burst switching
Aluminium/Plastic Frame
Removable Cover
Applications
Electrical Ovens, Kilns, or Furnaces
HVAC Heaters
Controlled Power Applications
Electric Boilers
Brewery Heating
Industrial Light Dimming
Suitable for HVAC or Industrial Environments
Specification
Fastron Part Number
TPR-3SL040H
Rated Operating Temperature
50°C
SCR Configuration
3 Phase AC Switch
Control Voltage
4-20mA (Default), 0-5V, 10K POT)
Load Current
32 Amps Per Phase @ 50 Deg C
Derating
2% per 1 Deg C (approx)
Control Range
0-100%
Alarms
2 x NO Relay Contact
Comms
Optional RS485 Modbus RTU
Special Feature
Internal Fuse
Mounting Style
Panel Mount
Switching Voltage Range
400VAC +/-10%
Supply Voltage
100-240VAC +/-10%
Delay on Start
NA
Soft Start
Programmable from 0 to 60 seconds
Termination Style
Screw
Unit Weight
4kg (6kg Packed)
Factory Pack Qty
1
Technical Docs
User Manual
Fastron TC5-S-S-2-G-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, Pt100 or Cu20, 48x48mm,12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
TC5-S-S-2-G-2
Control Output
12VDC
Input
Multirange Multirange Type K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Gigavac GXC15CEBV, CAN Bus Contactor SPST-NO, 350+ AMP, 12-800VDC, 24VDC Coil, 8 Pin Deutsch Connector, SPST-NO Auxiliary Contact, IP67, IP69K, with Voltage Sensing
Features
CAN Bus Comms
Voltage Sensing
Hermetically Sealed (Patented) rated to 175 Deg C
UL1604 for Class I & II Div 2 and Class III for use in hazardous locations
IP67 & IP69K
SAE J1171 External ignition protection
ISO8846 Protection against ignition around flammable gasses
CE Approved
High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power
Ideal for battery powered systems or where low power is needed
PWM option provides additional drive control flexibility
Built in Coils suppression for all DC Coils
Flexible package for installation
Chassi level power terminals
Salt Fog MIL-STD-810
Specification
Gigavac Part Number
GXC15CEBV
Main Contact Type
SPST-NO
Auxiliary Contact Type
SPST-NO
Coil Voltage
24VDC
Load Current
350+ Amp
Mechanical Life @ 0 Amp
1,000,000 Operations
Dielectric at Sea Level (leakage <1mA)
2.2kV rms
Control Input Terminals
38cm Flying Leads
Aux Contact Terminals
38cm Flying Leads
Special Feature
Hermetically Seal rated to 175 Deg C
Mounting Style
Panel Mount (M5)
Voltage Sensing
YES
Comms
CAN BUS
Load Voltage Range
12-800VDC
Standards
UL1604, IP67, IP69K, SAE J1171, ISO8846
Termination Style
M8 & Deutsch 8 Pin Connector
Unit Weight
440g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron TC5-H-1A-2-T/R-2 PID Controller, 100-240VAC with 2 3 Amp Relay Alarms, K,E,J Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x96mm,4-20mA Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-H-1A-2-T/R-2
Control Output
4-20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
TC5 Datasheet and User Manual
Fastron TC5-H-W-2-G-2, 100-240VAC PID Controller with 2 3 Amp Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Now available will full Multirange input (K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,4-20mA Output)
Specification
Fastron Part Number
TC5-H-W-2-G-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA
Input
Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 3 Amp Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Approvals
CE
Datasheet
TC5 Datasheet and User Manual