D53TP50D + HS212DR-F, Solid State Relay, and Heatsink Assembly, 3 Phase 4-32VDC Control, 36 Amp per phase @ 40 Deg C, 48-530VAC Load, LED Status Indicator
Features
Ratings from 25A to 50 Amp @ 70-530 VAC
SCR output for heavy industrial loads
Zero voltage or Instantaneous turn-on outputs
UL/CE/ROHS Approved
IP20 Cover Available
AC & DC control types
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D53TP50D + HS212DR-F
Switching Type
Zero Crossing
ROHS/CE/UL
Yes
Control Voltage
4-32VDC
Load Current
3 x 36 Amp (rms) per Phase
Surge Capability
597 Amp (peak)
Special Feature
LED Status Indicator
Mounting Style
Din Rail Mount
Load Voltage Range
48-530VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
315g
Factory Pack Qty
10
Datasheet
D53TP Series
3 Phase SSR and Heatsink Mounted
HS212 Datasheet
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Eastron Europe SDM230Modbus-MID-V2 (SLX), DIN Rail Mount kWh Meter, Single Phase, 240VAC aux, Class 1, 100Amp Direct Connect, w/ 2 x pulse outputs and RS485 Modbus RTU Comms, MID Approved,SAA212516
Fast CPU for 100ms Communication response time For Solaxx or Growatt Inverters.
Can be used for any 100 Amp Direct Connect application
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
1 x Configurable Pule Output (via Display Menu or Modbus)
1 x Fixed Pulse Output (1000imp/kwh)
SAA Approved
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy Class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM230Modbus-MID-V2 (SLX)
Functions
Single Phase Energy Meter
Supply Voltage
230V L-N +/-15% < 5VA
Nominal Measurement Range
230V L-N 230V L-N, 100 Amp
Maximum Measurement Range
276 L-N 230V L-N,100 Amp
Nominal Current Input
Direct connect 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
36mm x 100mm x 66mm (2 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (100ms Response)
Weight
250g
Certification
EN 61010-1 Installation Category III, SAA212516
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
Crydom M505012F, Bridge, single phase, half controlled, 240VAC input, 50 Amp, with freewheeling diode
Features
Package with DCB ceramic base plate
Isolation voltage 2500 V∼
Planar glass passivated chips
Low forward voltage drop
UL registered, E 148688
Applications
Heat and temperature control for industrial furnaces and chemical processes
Lighting control
Motor control
Power converter
Advantages
Easy to mount with two screws
Space and weight savings
Improved temperature and power cycling capability
High power density
Spec
Crydom Part Number
M505012F
AC Line voltage
240V
Device Configuration
Single Phase Half Controlled Rectifier Bridge
DC Output @ 100 Deg C
100 Amp
Package Size
W:57.5mm L:44mm D:34.6mm
Itsm
600 A
VF(to)
1.7V
Tj(max)
125°C
rF
N/A
Terminals
M5 (1.5Nm)
Hole Centres
41.2mm (M5)
Gate Terminals
N/A
R th(j-c)
0.7°C/W
R th(c-h)
N/A
Weight
106g
Isolation
2.5kV
Factory Pack Qty
10
Certification
UL Listed
Crydom Headquarters
USA
Datasheet
Product Datasheet
Alternatives
M5010012F
SDM630Modbus-MID-V2-CL1 (SDM630-M), DIN Rail Mount kWh Meter, 3 Phase, Class 1, 100 Amp Direct Connect input, w/ 2 x pulse outputs and RS485 Comms, MID Approved
3 x 100 amp Direct Connect
RS 485 communication up to 38,400 bit/s as standard
Optional Mbus Model available
True RMS values of currents and voltages
2 x Pulse Outputs (1 Configurable)
The meter is intended for measuring, and monitoring single-phase or electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power to the 30th Harmonic) from the measured signals.
Features :
Accuracy class 1
Measurement of Active and Reactive Power
Modbus RTU communication up to 38,400 bit/s communication
Pulse output as standard
Graphic LCD with illumination
Specification
Eastron Europe Part Number
SDM630Modbus-MID-V2-CL1 (SDM630-M)
Functions
Three Phase Energy Meter
Supply Voltage
NA
Nominal Measurement Range
415V L-L 230V L-N, 100 Amp
Maximum Measurement Range
480V L-L 230V L-N, 100 Amp
Nominal Current Input
Direct connect 3 x 100 Amp
Pulse Output
2 x Passive, (1 x Configurable 60/100/200ms)
Tariff Input
N/A
Accuracy
Class 1 (I,U,F,kW,kWh) Class 2 (Reactive)
Mounting
Din Rail
Real Time Clock
1min/month (30ppm)
Internal Memory
N/A
Dimensions
72mm x 100mm x 66mm (4 modules wide)
Isolation
4kV
RS485
2400-38400 b/s (400ms Response Time)
Weight
150g
Certification
EN 61010-1 Installation Category III
Factory Pack Qty
1
Safety
IP51(Indoor)
Enclosure Material
Noryl with fire protection to UL94-V-O. Self extinguishing
Enclosure Size
DIN 42880 4 Modules
Operating Temperature
-20 →+70 °C
Documents
Product Datasheet
User Manual
Modbus Protocol
Alternatives
WM3-6 230DB
Modbus Utility
EEM Meter Setting Software Utility
VX2-UCMD-A4TD2R, Temp Controller, 48x96mm, 24VAC/DC, Multirange Input, 4-20mA Output, Relay Cooling Output, 4 Alarms, Retransmission, Event Input (2x SV), Remote Setting Input
Multirange Input (Programmable)
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP65 (front panel only)
UL/CE Approved
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type)
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
VX2-UCMD-A4TD2R
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type K/J/E/T/R/B/S/L/N/U/W/PLII/PT100/JPT100/4-20mA/0-20mA/1-5V/0-5V/0-10V/0-50mV/0-100mV. Note for Direct Current Input please use 250 Ohm Resistor in Parallel to the input terminals.
Alarm
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 1
4 x Alarm Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Option 2
Event Input (2x SV), 4-20mA Remote Setting Input, Retransmission
Mounting Style
48 x 96mm Panel Mount
Supply Voltage
24VAC/DC
Termination Style
Screw
Weight
350g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
VX Series Brochure
VX Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
Crouzet 88975111, Millenium EVO Ethernet, Smart Relay with Display, 24 I/O, 24VDC, 8 Configurable Analogue/Digital Inputs, 4 x High Speed 15kHz Inputs, 4 x Std Digital Inputs, 2 x 6 Amp Relay, 6 x 8 Amp Relay
Up to 44 I/Os - 16 DI (4 HighSpeed / 8 AI) - 8 DO
Wireless programming & Control with bluetooth Interface and Crouzet Virtual Display
Modbus RTU Network (Slave)
Local datalog management
Up to 1000 programing blocks with intuitive Crouzet Soft to go from simple to complex applications
HMI Screens Available
Specification
Crouzet Part Number
88975111 (Millenium EVO)
Analogue Inputs
0 - 10VDC, 0-V Power Supply or Voltmeter
Digital Inputs
24VDC @ 2.1mA (8 Standard and 4 High Speed)
Digital Outputs
Relay, 24VDC, 250VAC @ 100mA minimum (2 x 6 Amp, 6 x 8 Amp)
PWM SSR Output
None
Expandable
Yes
Comms
Ethernet. (RS485, Bluetooth). Standard and Wifi versions available
LCD Display
Yes
Mounting Style
DIN Rail Mount (124.6mm)
Supply Voltage Range
24VAC (21.6 - 28.8VAC)
Termination Style
Screw
Weight
350g
Environmental
Reach, RoHS, Halogen free 1272/2008/CE
Certification
CE, cULus Listed
Factory Pack Qty
1
Over Voltage Category
3 in accordance with IEC/EN 60664-1
Pollution Degree
2 in accordance with IEC/EN 61131-2
Protection rating
IP40 (Front), IP20 (Rear)
Mechanical Resistance
Immunity to vibrations IEC/EN 60068-2-6, test Fc
Immunity to shock IEC/EN 60068-2-27, test Ea
Resistance to HF Interference
Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12
Conducted and radiated emissions
Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure)
Operating Temperature
-20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22
Datasheet
Product Datasheet
Launching Note
Software
Crouzet Touch Soft V6.00.02.173
Software M3-soft-AC9-V3.1.2.0_ML
Remote Control Software CVD_PC_V2_3_01_02
Crouzet Soft EVO EM4 1.12.01.14
Fastron Electronics BTCS/A-M1-A2-DA, PID Controller 48x48mm, 15-50VDC, 4-20mA output 2 Alarms, 4-20mA Cooling, Multirange TC/RTD/4-20mA Input
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Dust-proof IP56 (front panel only)
Optional 32 Step pattern (for SV and time) is a standard feature
CE Approved
Each unit needs just 80 mm depth panel space
Specification
Fastron Part Number
BTCS/A-M1-A2-DA
Control Output
4-20mA
Input
Multirange 4-20mA/RTD/Thermocouple (Optional Linear Voltage/Current other than 4-20MA Refer to datasheet)
Option 1
2nd Alarm
Option 2
4-20mA Cooling
Mounting Style
48x48mm Panel Mount
Load Voltage Range
15-50VDC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
CE
Yes
Datasheet
BTC Series Brochure
BTC Series User Manual
BTC Series RS485 Comms Manual
Fine Tuning PID Adjustments
BR6-FNMP3, Temp Controller, 48x24mm, 10-24VDC, TH-540N or NTC Input, Relay Output
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNMP3
Control Output 1 (Heat)
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
10-24VDC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
BR6-FNCP3, Temp Controller, 48x24mm, 10-24VDC, TH-540N or NTC Input, 4-20mA Output
4-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
CE Approved
Each unit needs just 60 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BR6-FNCP3
Control Output 1 (Heat)
4-20mA
Control Output 2 (Cool)
N/A
Input
TH-540N or NTC Input
Alarm
N/A
Option 1
N/A
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
10-24VDC
Termination Style
Screw
Weight
200g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BR6 Series Instruction Manual
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11
BS1-ND101, Digital DC Voltmeter, 48x24mm, 85-265VAC, Range : 0-199mVDC
3.5-digit displays suit most industries including Temperature, Humidity, Pressure (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
UL/CE Approved
Each unit needs just 100.2 mm depth panel space
EC Compliant
Specification
Hanyoung Nux Part Number
BS1-ND101
Input
0-199mVDC
Mounting Style
48 x 24mm Panel Mount
Supply Voltage
85 - 265VAC
Termination Style
Screw
Weight
250g
Factory Pack Qty
1
ROHS
Yes
UL
Yes
CE
Yes
Datasheet
BS1 Series Instruction Manual
BS1 Series Wiring and Selection Tables
Free Software
Hanyoung Nux TCS Software
Hanyoung Nux TCS Software User Manual
VX Series SB Driver (Windows 7) Not required for Windows 10 or 11