Furison SPS NET2, Miniature UPS, 230V input, 5/9/12VDC Output 18W (20W max), Lithium-Ion Battery 3/6V. 4 Hours Charging & Backuptime,
Features
10000 mAh lithium ion battery.
Cold start (battery start-up).
Multiple outputs 3 DC (5, 9 and 12 V) + 1 USB (5 V).
Supports up to 4 devices simultaneously. (Provided they don’t exceed 18 W)
Dual output cable with DC connectors and adapters (x2) compatiblewith the vast majority of routers on the market.
Rapid response from AC to DC in 0 ms
Silent advanced cooling system.
Compact and lightweight design.
V-0 flame-proof housing for extra safety
Short-circuit protection.
4 LEDs to indicate back-up time and failure
Automatic restart on network recovery.
ON/OFF button.
Wall mounting possible.
Specification
Furison Part Number
SPS NET2
Power Output
5/9/12VDC 18W(20W max)
Input
230VAC Plugpack / 12VDC Output to UPS
Output Connections
1 x USB, 3 x 2.5mm
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Weight
310g
Factory Pack Qty
1
Standards
EN62368-1, EN55032 Class B / EN61000-3-2 / EN61000-3-3 / EN55035
Datasheet
Download Datasheet
Electronicon 275.545-701900/221K02, 5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 75 x 164(+25 +5/-2)mm Gas Filled, 3 x 19uF, Internal Discharge Resistors
Characteristics and utility
5kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.545-701900/221K02
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75 x 164(+25)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
5 Kvar
Capacitance
3 x 19uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 9 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.6kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Fastron FRV 8-02/AD240, 50 to 270VAC Voltage Monitoring Relay, Single Phase Over/Under Voltage Detection, 1 x CO SPDT 10 Amp Contact, Adjustable Timer Delay, Adjustable Upper and Lower Voltage Limits
FRV 8 Series serves to monitor under/over voltage in switchboards, protection of devices in single phase 2 wire mains
Features
Upper and lower level of monitoring voltage
Adjustable time delay eliminates short voltage peaks and failures in the main
Supply is done from monitored voltage
Faulty state is indicated by red LED and by opening of output relay contact
Output contact 1 x Changeover / SPDT 10 A /250 V AC1
In case supply voltage falls below 60 %Un (U lower level) relay off immediately opens without delay
1-MODULE, DIN rail mounting
Specification
Technical Data
FRV 8-02
Supply and measuring
50-270VAC
Measured voltage
65-260VAC / 50 Hz
Level Umax
112.5 % Un
Level Umin
83 % Un
Burden
max. 2 VA
Hysteresis
2 %
Max. permanent overload
270 VAC/DC
Time delay T1
max. 500 ms
Time delay T2
adjustable 0.1-10 s
Output
Number of contacts
1 x changeover/ SPDT (AgNi / Silver Alloy)
Rating
10 A / AC1
Breaking capacity
2500 VA / AC1, 240 W / DC
Inrush current
10 A
Switching voltage
250 V AC1 / 24 V DC
Min. breaking capacity DC
500 mW
Indication of state
red LED
Mechanical life
1 x 107
Electrical life (AC1)
1 x 105
Other information
Operating temperature
-20 ... +55 °C
Storage temperature
-30 ... +70 °C
Electrical strength
4 kV (supply - output)
Operating position
any
Mounting
DIN rail EN 60715
Protection degree
IP 40 from front panel / IP 10 terminals
Overvoltage cathegory
III.
Pollution degree
2
Max. cable size (mm )2
solid wire max. 2x2.5 or 1x4 ; with sleeve max. 1x2.5 or 2x1.5
Dimensions
90 x 17,6 x 64 mm
Weight
69 g
Standards
EN 60255-6, EN 61010-1, RoHS, CE, CE
Datasheet
Product Datasheet
Fastron Monitoring/Time Relays Catalogue
For items in our catalogue which are not listed online please Contact Us for Possible Replacement
Application Notes
Relay in 3-phase main monitors size of phase voltage. It is possible to set two independent voltage levels and thus it is possible to set two independent voltage levels and monitor e.g. undervoltage and overvoltage independently. In normal state when voltage is within set levels, output relay is closed and red LED shines.
In case voltage exceeds or falls below the set levels, output relay opens and red LED shines ( LED indicates faulty state – flashes when timing). In case supply voltage falls below 60 % Un (UOFF lower level)relay immediately opens without delay and faulty state is indicated by red LED.In case timing is in progress and faulty state is indicated, timing is immediately stopped.
Crydom ED10F5, EMR plug in Solid State Relay, 48-72VDC control, 5 Amp 1-80V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED10F5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
48-72VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 80VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh Rish SIGMA 150 CTR5+5+5+5+5+5+5+5+5/5.CL1.5VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 150 CTR5+5+5+5+5+5+5+5+5/5.CL1.5VA
Technology
AC Current Transformer
Ratio
5+5+5+5+5+5+5+5+5/5
VA Rating
5VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
Crydom ED06D5, EMR plug in Solid State Relay, 5-15VDC control, 5 Amp 1-48V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED06D5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 48VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
HAIS 400-P O/L Hall Effect Current Sensor, 400 Amp, vref 0-5V Output, PCB Mount, 15x8mm sqr, X = 1%
Features
Bandwidth DC to 50kHz
Open loop transducer using Hall effect
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Wide dynamic range, 50 to 600 A in one package.
Applications
AC variable speed drives and servo motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies (UPS)
Switched Mode Power Supplies (SMPS)
Power supplies for welding applications
Specification
LEM Part Number
HAIS 400-P
Technology
Open Loop Hall Effect
Aperture
15 x 8mm Square
ROHS
Yes
Supply Voltage
5 VDC
Load Current (RMS + DC)
400 Amp
Overload Capability
+/- 600 Amp
Output
2.5 Vref
Isolation
2.5kV
Bandwidth
DC-50 kHz
Mounting Style
PCB Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
PCB
Unit Weight
30g
Factory Pack Quantity
10
Datasheet
Product Datasheet
Xmer CT Split 93/30SC 300/5 Class 0.5 2.5VA, 23 x 33mm Aperture
Features
Quick Release Split Core System
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Xmer CT Split 93/30SC 300/5 Class 0.5 2.5VA
Technology
Split Core AC Current Transformer
Ratio
300/5
Aperture Size
23 x 33mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
200Amp x 1.2
Termination Style
Screw
Unit Weight
600g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron Electronics GBMC-5-N2-R2NN, 140x420mm, Pulse Input Counter/Totaliser NPN 12V input 4 Digit, Large Panel Meter, 100-240VAC/DC Supply
Adjustable Zero and Span Setting
Adjustable Display Scaling
Remote Control Included
Wall Mount
LED Tile Display
Large 4 Digit 100mm (40 Inch) LED Display
250mS Response Time
PC 94 UL V0
100mm Depth
CE Approved
Specification
Fastron Electronics Part Number
GBMC-5-N2-R2NN
Conditioner Output
None (optional)
Relay Outputs
2
Input
0-3kHz NPN 12VDC
Over Range
x 1.5
Operating Temperature
0 - 60°C
Supply Voltage
100-240VAC/DC
Span Adjustment Range
N/A
Zero Adjustment Range
N/A
Termination Style
Screw
Mounting Style
140 x 420 mm Wall Mount
Case Material
PC - UL 94 V0
Weight
3.6kg
Factory Pack Qty
1
Datasheet
Product Datasheet
Application Notes
Panel Meters Blog Articles
LEM AT 5 B10, AC Current Transformer, Self Powered, 5 Amp Average RMS 0-10V output
Features
Split Core
0-10V Average RMS Current Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B420L
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
0-10V (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
45 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet