Crydom ED24D5, EMR plug in Solid State Relay, 3-15VDC control, 5 Amp 24-280VAC output
Features
Ratings 5 Amp @ 24-280VAC
Plug in EMR relay style
Motor controller rated
SCR output for reliable AC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED24D5
Switching Type
AC Load
ROHS
Yes (Details)
Control Voltage
5-15VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base, PCB Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
38g
Factory Pack Qty
10
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh CT 50/5 Class 1 10VA 74W (45) Series Current Transformer, HIGH BURDEN, Without Aperture
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (45mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
CT 50/5 Class 1 10VA 74W (45)
Technology
AC Current Transformer
Ratio
50/5
Aperture Size
No Apeture. Cable passed through P1(Incoming) and P2(Load Side) terminals
VA Rating
10VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
50Amp x 1.2
Termination Style
Screw
Unit Weight
450g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer 62-30 (40) 600/5 Class 0.2S, 6.25VA, 31mm Aperture
Features
High Accuracy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 62-30 (40) 600/5 Class 0.2S
Technology
AC Current Transformer
Ratio
600/5
Aperture Size
31x11mm (30mm)
VA Rating
6.25VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Hobut CTSC CLIP 300/5 Series Current Transformer
Features
Low Price Point
Split Core
1m Flying Leads
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Flame Retardent UL94V0
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Site Measurements
Specification
Hobut Part Number
CTSC CLIP 300/5
Technology
Split Core AC Current Transformer
Ratio
300/5
Aperture Size
⌀ 40mm
VA Rating
2.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount
Operating Temperature Range
-30°C / 80°C
Continuous Current (max)
300Amp x 1.2
Termination Style
Screw
Unit Weight
800g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer 62-30 (40) 500/5 Class 0.2S, 5VA, 31mm Aperture
Features
High Accuracy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 62-30 (40) 500/5 Class 0.2S
Technology
AC Current Transformer
Ratio
500/5
Aperture Size
31x11mm (30mm)
VA Rating
5VA
Accuracy Class
Class 0.2S
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Rish Xmer 74-20 (45) 100/5 Class 1 7.5VA, 21mm Aperture
Features
High Accuravcy Class 0.2S
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish Xmer 74-20 (45) 100/5 Class 1 7.5VA
Technology
AC Current Transformer
Ratio
100/5
Aperture Size
21x11mm
VA Rating
1.5VA
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-25°C / 40°C
Continuous Current (max)
Ipn x 1.2
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
9
Datasheet
Product Datasheet
Fastron FTCK Series Type K Thermocouples MIMS Class A, Standard Sizes and Lengths 3mm or 5mm Shaft, Braided SS/Fibreglass/Teflon Tail, 304 Stainless Steel Sheath, CE ANSI ROHS Approved, -20 to 800 Deg C
Class A Accuracy
CE, ANSI, ROHS Approved
Kink proof Fiberglass Reinforced SS Braided Cable
Low Long Term Drift
Rated for -20 to 800 Deg C Max
Spring Cable Connection
50 - 500mm or custom
Sheath Thickness 3/5/9mm or custom
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FTCK Series
Sensor Type
Type K Thermocouple
No of Wires
2
Probe Length
50-500mm or custom
Sheath Thickness
3/6/9mm or custom
Sheath Material
SS 304 Stainless Steel
Aprovals
CE, ANSI, ROHS
Accuracy
Class A
Cable length
3 Meters (Standard) or custom
Cable Type
Teflon/Fibreglass/Braided Stainless Steel
Temperature Range
-20 to 800 Deg C
Special Feature
Spring Cable Strain Relief
Mounting Style
BSP Bayonet or Flange Fitting Recommended
Weight
300-500g
Factory Pack Qty
1
Datasheet
Type K Datasheet
Type K 100mm Datasheet
Type K 50mm Datasheet
Crydom ED10C5, EMR plug in Solid State Relay, 18-32VDC control, 5 Amp 1-80V DC output
Features
Ratings 5 Amp @ 60/80VDC
Plug in EMR relay style
Motor controller rated
Mosfet output for reliable DC switching
Multiple modules can be wired in parallel for higher currents
UL/CSA/VDE Approved, CE Compliant to EN60950-1
EMC compliant to Level 3
Epoxy free design
Spec
Crydom Part Number
ED10C5
Switching Type
DC Load
ROHS
Yes (Details)
Control Voltage
18-32VDC
Load Current
5 Amp DC
Surge Capability (10ms)
60 Amp DC
Special Feature
Plug in EMR style
Mounting Style
EMR Base
Load Voltage Range
1 - 80VDC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
11g
Factory Pack Qty
20
Datasheet
Product Datasheet
Socket
DRSED
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Rishabh Rish SIGMA 75 CTR5+5+5+5+5/5.CL1.15VA Summation Current Transformer
Features
DIN Rail Mounting Clip Included
Built In Sealable Terminal Covers
Mounting Feet Supplied
Narrow Width (30mm)
Self Powered
Rated System Voltage 0.72/3kV
IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1
Applications
Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Rishabh Part Number
Rish SIGMA 75 CTR5+5+5+5+5/5.CL1.15VA
Technology
AC Current Transformer
Ratio
5+5+5+5+5/5
VA Rating
15VA Class 1
Accuracy Class
Class 1
Output
5 Amp AC (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Din Rail Mount
Operating Temperature Range
-30°C / 85°C
Continuous Current (max)
8 Amp
Termination Style
Screw
Unit Weight
500g
Factory Pack Qty
5
Datasheet
Product Datasheet
Furison SPS NET2, Miniature UPS, 230V input, 5/9/12VDC Output 18W (20W max), Lithium-Ion Battery 3/6V. 4 Hours Charging & Backuptime,
Features
10000 mAh lithium ion battery.
Cold start (battery start-up).
Multiple outputs 3 DC (5, 9 and 12 V) + 1 USB (5 V).
Supports up to 4 devices simultaneously. (Provided they don’t exceed 18 W)
Dual output cable with DC connectors and adapters (x2) compatiblewith the vast majority of routers on the market.
Rapid response from AC to DC in 0 ms
Silent advanced cooling system.
Compact and lightweight design.
V-0 flame-proof housing for extra safety
Short-circuit protection.
4 LEDs to indicate back-up time and failure
Automatic restart on network recovery.
ON/OFF button.
Wall mounting possible.
Specification
Furison Part Number
SPS NET2
Power Output
5/9/12VDC 18W(20W max)
Input
230VAC Plugpack / 12VDC Output to UPS
Output Connections
1 x USB, 3 x 2.5mm
Mounting Style
71 x 29mm Panel Mount
Supply Voltage
230VAC
Termination Style
Screw
Weight
310g
Factory Pack Qty
1
Standards
EN62368-1, EN55032 Class B / EN61000-3-2 / EN61000-3-3 / EN55035
Datasheet
Download Datasheet
LEM AT 5 B5, Split Core AC Current Transformer, Self Powered, 5 Amp Avg RMS 0-5V outputFeatures
Split Core
0-5V Average RMS Output
Cable Mounting
Self Powered
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable up to ? 16mm
High isolation between primary and secondary circuits
Easy installation
Applications
Current Measurement
Energy Management
Motor Control
Actuators
Lamp Failure
Specification
LEM Part Number
AT 5 B5
Technology
AC Current Transformer
Protection Class
IP50
Supply Voltage
Self Powered
Load Current (RMS)
5 Amp
Maximum Measurement Current (RMS)
6 Amp
Output
0-5V (Average RMS)
Isolation
3.5kV (AC, 50Hz, 1 min)
Bandwidth
55 - 65Hz
Mounting Style
Din Rail Mount
Operating Temperature Range
-10°C / 65°C
Accuracy
1.5%
Aperture
? 16mm
Termination Style
Screw
Approvals
CE,UL,ROHS
Unit Weight
90g
Factory Pack Qty
6
Datasheet
Product Datasheet