Search results for "텔레@koreatalk77$*안전한라우터판매카카오톡해킹가격"
-
MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms
Iskra Doo MT440-SSUDAAAAA, Multifunction Power Transducer, Class 0.5, 4 Wire, 600V 1/5/10Amp AC Input 50/60Hz, 24-300VDC or 40-276VAC Aux Input, 4 Programmable Analogue Outputs, RS485 + USB Comms Class 0.5 (EN 60688) USB Comms as standard Up to 4 I/O Modules (analogue output, Multiple break point, non-linear characterstics Automatic range of nominal current up to 12.5 A (Includes 5A/1A CT Input) and nominal voltage up to 600 V L-N Adjustable tariff clock, display of electric energy consumption in optional currency RMS values of currents and voltages Measurements of active, reactive, apparent power and power factor Measurements of energy in all 4 quadrants Average values of measurands per interval Certified ship version available The Power Transducer is intended for measuring, analysing and monitoring single-phase or three-phase electrical power network. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current, frequency, energy, power, power factor, phase angles, etc.) from the measured signals. Features : Measurement of instantaneous values of more than 50 quantities (U, I, P, Q, S, PF, PA, f, f, MD, etc.). Accuracy class 0.5 32 Adjustable Alarms Input frequency 50/60 Hz or 400 Hz RS 232/RS485 communication up to 115,200 bit/s (Optional) or USB communication as standard MODBUS RTU communication protocol Up to 4 inputs or outputs (pulse outputs, alarm outputs, tariff inputs) Universal Supply 24-300VDC or 40-276VAC Automatic range of nominal current up to 12.5 A and nominal voltage up to 600 V User-friendly PC MiQen software Specification Iskra Doo Part Number MT440-SSUDAAAAA Functions 3 Phase Power Transducer Supply Voltage 24-300VDC or 40-276VAC Nominal Measurement Range 600V L-N, 1/5/10 Amp Maximum Measurement Range 600V L-N, 12.5 Amp Alarm N/A Tariff Input N/A Output 4 x Analogue Accuracy Class 0.5 (I,U,F,PF,θ,THD) Class 1(Active), Class 2 (Reactive) Battery Backup N/A Real Time Clock 1min/month (30ppm) Isolation 3.5kV Comms USB (standard) RS485 2400-115200 b/s (RS232 Optional) Weight 370g Enclosure Material UL94, Factory Pack Qty 1 EU Directives EN61010, EN60688,EN61326-1,60529,60068-2-1/-2/-6/-27/-30 Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software MiQen Setting Software MIPACK Programmer
$1,145.00
$1,351.10 inclGST -
DEVD200E1DA4, Contactor SPST-NO Non Polar, 200 AMP, 12-800VDC, 12-36VDC Coil, SPST-NO Auxiliary Contact
Fastron Electronics DEVD200E1DA4, Contactor SPST-NO Non Polar, 200 AMP, 12-800VDC, 12-36VDC Coil, SPST-NO Auxiliary Contact Features Hermetically Sealed with inert gas CE, CCC Approved Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Side mounted version available Specification Fastron Part Number DEVD200E1DA4 Main Contact Type SPST-NO (silver plated copper) Auxiliary Contact Type SPST-NO Coil Voltage 12-36VDC Load Current 200 Amp Mechanical Life @ 0 Amp 200,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals Lead Wire Connection Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 800VDC Standards CE, CCC Termination Style M8 Unit Weight 550g Factory Pack Qty 1 Datasheet Product Datasheet
$200.00
$236.00 inclGST -
Rish Xmer 155/80 1500/5 Split Core CT Class 0.5 20VA, 85 x 125mm Aperture
Rishabh Xmer CT Split 155/80 1500/5 Class 0.5 20VA Series Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 1500/5 SCCT Class 0.5 20VA Technology Split Core AC Current Transformer Ratio 1500/5 Aperture Size 85 x 125mm VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
$295.00
$348.10 inclGST -
EM94-Z-V2-M-R, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 61-200VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60V AC/DC Aux Supply, Internal Logging
Free Aus Post Shipping for $300 spendRisbabh EM94-Z-V2-M-M, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 61-200VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,10-60V AC/DC Aux Supply, Internal Logging 2 Pulse/Alarm Outputs 50-150mV Shunt Input, and nominal voltage 60-300VDC RS 485 communication up to 57,600 bit/s USB Port 8MB Internal Storage 4 x DC Measurement Only The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.5 Simple Menu RS 485 communication up to 57,600 bit/s USB Comms 8MB Internal Logger 10-60VAC/DC power supply Specification Rishabh Part Number EM94-Z-V2-M-M Functions kWh Meter, Energy Meter Supply Voltage 10-60VAC/DC Nominal Measurement Range 61-200VDC Maximum Measurement Range 61-200VDC Display 4 Line LCD Pulse/Relay Output 2 Accuracy Class 0.5 (Energy) USB YES Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS485 Modbus RTU YES 57,600bps Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Free Aus Post Shipping for $300 spend$259.00
$305.62 inclGST -
IKA40-31-R-24VAC, 4 Pole Configuration_SPST (1 x NC), 3 x SPST NO Modular Contactor 440VAC 40 Amp, 24VAC/DC Control Voltage, with Manual Overide
Iskra IKA40-31-R-24VAC/DC, 4 Pole Configuration_SPST (1 x NC), 3 x SPST NO Modular Contactor 440VAC 40 Amp, 24VAC/DC Control Voltage, with Manual Overide Features 40 Amp (rms) @ 440VAC DIN Rail Mount Changeover Contact Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number IKA40-31-R-24VAC Switching Type 3 x SPST NO, Configuration_SPST (1 x NC) Approvals CE Coil Voltage 24VAC/DC Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Manual Overide Mounting Style DIN Rail Mount Load Voltage Range 440VAC Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Contactor Datasheet
$63.00
$74.34 inclGST -
GT-DVO(10-30V)A-1, DC Voltage Transducer, 10-30VDC input, 100 - 240VAC/DC aux, 4-20mA output
Free Aus Post Shipping for $300 SpendFastron Electronics GT-DVO(10-30V)A-1, Signal Isolator/DC Voltage Transducer, 10-28VDC input, 100 - 240VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-DVO(10-30V)A-1 Control Output 4-20mA Input 10-30V Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100 - 240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$219.00
$258.42 inclGST -
GT-DVO(10-30V)D-1, DC Voltage Transducer, 10-30VDC input, 22-60VAC/DC aux, 4-20mA output
Free Aus Post Shipping for $300 SpendFastron Electronics GT-DVO(10-30V)D-1, Signal Isolator/DC Voltage Transducer, 10-28VDC input, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-DVO(10-30V)D-1 Control Output 4-20mA Input 10-30V Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
Free Aus Post Shipping for $300 Spend$219.00
$258.42 inclGST -
DKIH-3242-16D9, Schurter Choke 16Amp, 2 x 0.9mH
Schurter DKIH-3242-16D9 Choke Features Current compensated choke 1-phase choke THT-terminals Flange for mounting onto printed circuit board Compact size and light weight Open design for optimal cooling Nanocrystalline or ferrite ring cores Customer specific pin outs available Applications Frequency converter Charge stations UPS-systems Switching power supplies Specification Schurter Part Number DKIH-3242-16D9 Rated Voltage 300VAC (UL,IEC), 425VDC max Rated Current 16A Inductance 2 x 0.9mH -30%, +50% Operating Temperature -25°C to 125°C Resistance (Rcu) 5.6mΩ Resonant Frequency 0-400 Hz Mounting THT PCB Mount Material Thermoplastic, black, UL 94V-0 Termination Style THT Terminals Weight 50g Factory Pack Qty 1 Climatic Category 40/125/21 acc. to IEC 60068-1 Isolation 2.5kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet Application Notes
$26.88
$31.72 inclGST -
100BF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 100BF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style Features Equivalent to Mersen 6.9 URGL 36/110 P097165 British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 100BF Fuse Type I²t aR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 6000 A²/s I²t Rating (IP > 30IN) 6700 A²/s Nominal Current (RMS + DC) 100 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 79.4 x 24 x 110mm Hole Centers 75.2 x 93.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 50W Termination Style M6 Unit Weight 220g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$48.00
$56.64 inclGST -
GFIN/100M-DR + PMP4850WP, DIN Mount, Proportional Controller, 380-480VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection
GFIN/100M-DR + PMP4850WP, DIN Mount, Proportional Controller, 380-480VAC 50 Amp @ 40 Deg C, Selection for Burst/Phase Angle, 4-20mA, 0-10V, 0-5V Input, Din Rail Mount, with Overvoltage Protection Selectable Proportional Phase or Burst Control Input Ratings from 25A to 90 Amp @ 170-600 VAC SCR output for heavy industrial loads Zero voltage or Instantaneous turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Specification Crydom Part Number GFIN/100M-DR + PMP4850WP Switching Type Phase Angle or Burst (Selectable) ROHS/CE/UL Yes Control Voltage 0 - 10V/0 - 5V/4 - 20mA Proportional Input (Selectable) Note Requires DC Power Supply for 0-5V/0-10V input modes Load Current 50 Amp (rms) Surge Capability 597 Amp (peak) Special Feature Proportional Controller + SSR + Overvvoltage Protection Mounting Style Panel Mount Load Voltage Range 345-530VAC Dielectric Strength 4kV Termination Style Terminal Plug Unit Weight 1000g Factory Pack Qty 20 Datasheet PMP24 Series Datasheet PMP24 Installation/Wiring Guide GFIN Equivalent Parts Contact Us for Possible Replacement
$298.00
$351.64 inclGST -
EM94-Z-V2-L-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 61-200VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60V DC Aux Supply, Internal Logging
Free Aus Post Shipping for $300 spendRisbabh EM94-Z-V2-L-D, Panel Mount DC kWh Meter, Class 0.5, 50-150mV Shunt input, 61-200VDC, 2 Alarm/Pulse Outputs, RS485 & USB Comms, Single Line LCD Display,12-60V DC Aux Supply, Internal Logging 2 Pulse/Alarm Outputs 50-150mV Shunt Input, and nominal voltage 60-300VDC RS 485 communication up to 57,600 bit/s USB Port 8MB Internal Storage DC Measurement Only The meter is intended for measuring, analysing and monitoring DC Power. The meter records TRMS value according to the principle of fast sampling of voltage and current signals. A built-in microprocessor calculates measurands (voltage, current,, energy, power.) from the measured signals. Features : 96 x 96mm Panel Mount Accuracy class 0.5 Simple Menu RS 485 communication up to 57,600 bit/s USB Comms 8MB Internal Logger 60-300VAC/DC power supply Specification Rishabh Part Number EM94-Z-V2-L-D Functions kWh Meter, Energy Meter Supply Voltage 60-300VAC/DC Nominal Measurement Range 61-200VDC Maximum Measurement Range 61-200VDC Display Single Line LCD Pulse/Relay Output 2 Accuracy Class 0.5 (Energy) USB YES Real Time Clock 1min/month (30ppm) Isolation 3.5kV RS485 Modbus RTU YES 57,600bps Weight 450g Certification EN 61010-1 Installation Category III Factory Pack Qty 1 Environment IP54 Safety Protection Class II Enclosure Material Mablex with fire protection to UL94-V-O. Self extinguishing EnclosureSize 96 x 96mm x 83.5mm (72mm behind panel) Terminals Rising Cage 4mm² (12 AWG) cable max Humidity < 75% Non Condensing Operating Temperature -20 →+70 °C Datasheet Product Datasheet Software Software User Manual Software Download Link Application Notes 1)Reading Data from Registers -> Download file 2)Maximum Memory Size -> Read below Max Available Memory Locations in 8MB Size = 273030 Actual parameter stored in Each log (Memory locations used) = Date +time+Number of parameter selected by user Considering your example for 2 parameters: Number of parameter selected by user = 2 (kwh & kVA) Actual parameter stored in Each log = 1(Date) +1(time)+ 2 (Parameters) = 4 (memory locations used per log) Maximum log that can be stored = Max Memory Location/Actual parameter stored in Each log =273030/4= 68257 Timelog Interval setting = 15 minutes Log in one day = (60 /Timelog Interval setting) * 24 =(60/15)*24 = 96 Logs Max Days = Maximum log that can be stored / log in one day = 68257 / 96 = 711 days = 1 Year & 11 Months = 23 Months.
Free Aus Post Shipping for $300 spend$309.00
$364.62 inclGST -
100AF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style 200kA Breaking
Trent 100AF Series 690V, 100 Amp aR Semiconductor I²t Fuse BS88 Style Features Equivalent to Bussmann 100FE, ETI BS17UQ/63/100A/690V British Standard Fuse Links Package Wide Range of I²t Ratings up to 1000 Amp Busbar or Standoff Mounting IEC Standard 60269.1 AND 4 690 V Voltage Rating complying with IEC 33 Applications Protection of High Powered Semiconductors according to I²t Short Circuit Protection DC or AC Motor I²t Protection Battery Fuse Specification Trent Part Number 100AF Fuse Type I²t AR Class Nominal Voltage 690VAC @ 50Hz I²t Rating (IP < 30IN) 4800 A²/s I²t Rating (IP > 30IN) 6200 A²/s Nominal Current (RMS + DC) 100 Amp Tested Breaking Capacity 200kA @ 690VAC Dimensions 17 x 49mm Hole Centers 60.9 - 65.6mm Mounting Style Busbar or Panel Mount with Standoff Operating Temperature Range -40°C / 125°C Watt Loss 25W Termination Style M6 Unit Weight 61g Factory Pack Qty 10 Datasheet Product Datasheet Cross Reference Chart
$36.10
$42.60 inclGST