Iskra IPO-24, 24 Module Compact Distribution Boards, Flush Mounted IP40, 15 x PE and 15 x N Conductor Terminals
Features
IP40 Protection Class
RAL 7035
Double Insulation
IEC 60670-1, IEC 60670-24
INstallation Temperature -20 to 60 Deg C
Glow Wire Test 650 Deg C
15 x PE and 15 x N Conductor Terminals
Datasheet
Product Datasheet
PFC 12-6-R-RTC, Power Factor Regulator & Kwh Power Quality Meter 144x144mm (Epcos BR 6000) wit RTC, 6 Step, 30-550V 50/60HZ, 240VAC Aux
Single 1/5A CT Sensing
Automatic Step Sensing (After start up sequence)
Isolated Switching of Power Factor Correction Contactors
Cos ϕ Setting 0.85 to 0.95 CAP
Auto CT Secondary Selection
Backlit LCD Display
Various Program Combinations
IP41
Up to 6 steps
Measurement System - Automatic/Manual
240VAC Aux Supply
Modbus RS485
Configurable Alarms
Dual Password Protection
Programmable Fan Control
Programmable 1A/5A CT Ratio
Specification
Rishabh Part Number
PFC 12-8-R-RTC
Function
Reactive Power Correction
Nominal Voltage (Un)
110-480VAC Line to Line
Supply Voltage
240VAC (L-N), 15VA 40-70Hz +/-10%
Relay Rating
250VAC/10Amp
Panel Size
144 x 144mm
Switch Delay Time
10s - 1800s User Adjustable
Alarm
1 x Relay as above
Temperature Alarm
1 x Relay as above
Re-connection Delay Time
10 - 1800s User Adjustable
Desired Power Factor
0.80 IND - 0.80 CAP
Number of Output Relays
7
Smallest Capacitor Current
10mA
CT Input Range
1/5 Amp
LCD Display Accuracy
Voltage +/-0.5%, Frequency +/-0.1%, Power +/-1% Energy Class 1
Phase Angle Error
+/- 1% at I > 3% of range
Comms
RS485
Termination Style
Screw
Weight
700g
Certification
IEC 61326-1:2012, Table 2 (EMC), IEC 62053-21 (Accuracy), IEC 61010-1-2010 (Safety), IEC60529 (IP Rating Dust & Water)
Factory Pack Qty
1
Material of housing
PC/ABS Unflammable, according to UL 94 V-0
Enclosure protection
IP50 for case, IP20 for terminals
Safety
According to IEC 61010-1-2010, installation category III Pollution degree 2
Operating Temperature
-20...60 °C
Datasheet
Product Datasheet
User Manual
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Quick Start Guide(Blog)
LEM AHR 500 B420, Hall Effect Current Transducer, 500A, 4-20mA True RMS output, 20-50VDC supply
Compact and versatile transducers for high AC and DC currents from 500 to 2000A True RMS with signal conditioning. Choice of output types: 4-20 mA, 0-5 V or 0-10 V, Bandwidth: DC 20..6000 Hz
Features
Split Core
VFD and SCR waveforms current measurement
True RMS output
4-20mA current output
Busbar mounting
Eliminates insertion loss
Isolated plastic case recognised according to UL94-V0
Advantages
Large aperture for cable or busbar up to 104 x 40mm
High isolation between primary and secondary circuits
Easy installation
Applications
-AC Power Supplies or Motors
True RMS sensing - the most accurate way to monitor power supply or input power
-VFD Controlled Loads
VFD output indicates how the motor and attached load are operating
-SCR Controlled Loads
Accurate measurement of phase angle fired or burst fired(time proportional) SCR's and switch mode rectifiers. Current measurement gives faster response than temperature measurement.
-Renewable Energy Installations or Backup Batteries
Continuous condition monitoring allowing automatic failure detection and prediction
-Application Domain
Energy and Automation
Specification
LEM Part Number
AHR 1500 B420
Technology
Open Loop Hall Effect
ROHS
Yes
Supply Voltage
20 - 50V
Nominal Current (RMS + DC)
500 Amp
Maximum Measurement Current (Peak)
2000 Amp
Output
4-20mA
Isolation
5.8kV (AC, 50Hz, 1 min)
Bandwidth
20-6000Hz
Mounting Style
Panel Mount
Operating Temperature Range
-40°C / 70°C
Accuracy
1%
Termination Style
SFKC 2.5/4-ST-5.08-RF(Phoenix Contact)
Unit Weight
650g
Factory Pack Qty
6
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
MTC400-36-415F3D, Dual Thyristor Module, 400 Amp, 3600V, 60mm package
Features
Thyristor for line frequency
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
Long-term stability
3600V Isolation
50mm Base Width
Applications
Power Converter
Line rectifying 50/60 Hz
Deep Cycle Applications
Controlled Rectifiers
Softstart AC motor control
AC power control
Lighting and temperature control
Specification
Techsem Part Number
MTC400-36-415F3D
Vrrm
3600V
Diode Configuration
Dual Thyristor Module
IF(av) @ 85 Deg C
400 Amp
Package Size
W:60mm L:115mm D:52mm
Itsm
12.5 kA
VF(to)
0.98V
Tj(max)
125°C
rF
0.88mΩ
I(gt) @ 25 Deg C
30-200mA
Terminals
M10 Screw
Hole Centres
112mm x 48mm(M6)
Gate Terminals
Spade (A 2.8 - 0.8 DIN 46244)
R th(j-c)
0.054°C/W
R th(c-h)
0.024°C/W
Weight
1500g
Mounting Torque
5 Nm (12 Nm Terminals)
Factory Pack Qty
8
Certification
UL Listed, ROHS
Techsem Headquarters
China
Datasheet
Product Datasheet
Schurter 4783.0000, IEC Appliance Inlet C13/F Plug, Black, Rewirable, for 10mm Cable, 70 Deg C Pin Temp
Features
Panel Mount : Snap-in Mounting from Front Side
Appliance Inlet C13/F Plug acc to IEC 60320-1
Screw On Mounting
70 °C pin Temperature
Characteristics
UL 60320-1, CSA C22.2 no. 60320-1 (for hot conditions) pin-temperature 120 °C, 10A, Protection Class I
Other Pin versions available on request
Types for enhanced glow wire test requirements acc. IEC 60695-2- 12 and -13 for the use in unattended household equipment acc. IEC 60335-1
Specification
Schurter Part Number
4782.0000
Rated Voltage
250V
Rated Current
10A (CE) 15A (UL/CSA)
Operating Temperature
-25°C to 70°C
Filter Type
N/A
Fuse Holder
N/A
Line Switch
N/A
Mounting
Wire Screw Mount
Material
Thermoplastic, black, UL 94V-0
Termination Style
C13 Female to Screw Terminal
Weight
40g
Factory Pack Qty
1
Protection Class
From front side IP30 acc. to IEC 60529
Isolation
2kV
VDE/UL/CSA/CE/ROHS
Yes
Datasheet
Product Datasheet
FPT-135 2000/1A 5P20 15VA Protection Class CT, 2000/1A, Class 5P20 15VA, 135 x 81mm Aperture
Features
Built In Sealable Terminal Covers
Mounting Feet Supplied
Self Powered
Rated System Voltage 0.72/3kV
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Applications
Protection Relays
Safety Equipment
Fault Monitoring
Specification
Fastron Electronics Part Number
FPT-135 2000/1A 5P20 15VA
Technology
Protection Class Current Transformer
Ratio
2000/5
Aperture Size
81 x 135mm
VA Rating
15VA
Accuracy Class
Class 5P20
Output
1 Amp AC (?%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Panel Mount/Busbar Mount
Operating Temperature Range
-10??C / 50??C
Continuous Current (max)
2000Amp x 1.3
Termination Style
Screw
Stanbards
VDE0414-44-1, GB1208-2006, EN 60044-1 and IEC 61869-2
Unit Weight
7kg
Factory Pack Qty
1
??
Datasheet
Product Installation Guide and Datasheet
??
Crydom D2440D, Dual Solid State Relay, Two Pole 4-15VDC Control, 2 x 40A, 24-280VAC Load
Features
Ratings from 2 x 25A to 2 x 40 Amp @ 24-530 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
D2440D
Switching Type
Zero Crossing (Dual)
ROHS
Yes (Details)
Control Voltage
4-15VDC
Load Current
2 x 40 Amp (rms)
Surge Capability
597 Amp (peak)
Special Feature
Dual SSR
Mounting Style
Panel Mount
Load Voltage Range
24-280VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Iskra IPO-12, 12 Module Compact Distribution Boards, ABS/PC, Panel Mounted IP40, 15 x PE and 15 x N Conductor Terminals Terminals
Features
IP40 Protection Class
RAL 7035
Double Insulation
IEC 60670-1, IEC 60670-24
Installation Temperature -20 to 60 Deg C
Glow Wire Test 650 Deg C
10 x PE and 10 x N Conductor Terminals
Datasheet
Product Datasheet
Crydom 10PCV2425, 2-10V Input Proportional Solid State Relay/Controller, 100-240VAC, 25 Amp
Features
2-10V Proportional Phase Control Input
Ratings from 25A to 90 Amp @ 70-280 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
UL/CE/ROHS Compliant
Includes Plastic IP20 Terminal Cover
Direct bond copper substrate
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
10PCV2425
Switching Type
Phase Angle (Random Crossing)
ROHS/CE/UL
Yes
Control Voltage
2 - 10V Proportional Input
Load Current
25 Amp (rms)
Surge Capability
250Amp (peak)
Special Feature
Proportional Controller + SSR
Mounting Style
Panel Mount
Load Voltage Range
180-280VAC
Max Non Repetitive Peak Voltage
600 Vp
Termination Style
Barrier Strip Screw
Unit Weight
160g
Factory Pack Qty
20
Datasheet
Product Datasheet
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
Relequick RS1APV010DC280040R Contact Us for Possible Replacement
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
Crydom CY9007, Solid State Relay 660VAC 25A, w/ Terminal Cover and LED Status Indicator, Equivalent to D2425, HD4825, HD6025
Features
Ratings from 25A to 125 Amp @ 24-660 VAC
SCR output for heavy industrial loads
Zero voltage or instantaneous turn-on outputs
CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
AC & DC control types
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
Spec
Crydom Part Number
CY9007
Switching Type
Zero Crossing
ROHS
Yes
Control Voltage
4-32VDC
Load Current
25 Amp (rms)
Surge Capability
297 Amp (peak)
Special Feature
LED Status Indicator, IP20 Terminal Cover
Mounting Style
Panel Mount
Load Voltage Range
90-660VAC
EMC Compliant
Level 3
Termination Style
Screw
Unit Weight
75g
Factory Pack Qty
20
Datasheet
Product Datasheet
Heatsink Options
Notifications
Please note Changes from Gen 3 to Gen 4 (current) package design here
Equivalent
D2425T, HD4825
App Notes
Why Use SSR's?
The inside story
Selecting a SSR
DC Output SSR's
Selecting a Suitable Heatsink
Use of Thermal Interface Material
How to Verify the Proper Heatsink
Effect of Forced Air Cooling
Fuse Protection of SSR's
Overvoltage Protection "P" Option MOV
SSR Reliability Whitepaper
3 Phase Motors and Heating Applications
3 Phase Motor Reversing
How to test a SSR
SSR Precautions
SSR Life Expectancy MTBF
ROHS & Reach Statement
Heatsink
SSR and Heatsink Assemblies
E62.C58-471E10, 0.47uF, 30x58mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 2000VDC/1200VAC
Characteristics and utility
0.47uF 2000VDC/1200VAC
Metalized Polypropylene Film
Connector type - M6 x 12mm Studs
M8 Stud mounting
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
E62.C58-471E10
Technology
Metalized Polypropylene Film Capacitor
Dimensions
ø30x58mm
Mounting
M8 Stud
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
2000VDC/1200VAC
Operating Temperature Range
-40 to 85 °C
Capacitance
0.47uF
Tolerance On Capacitance
+10 / -10%
Lifetime
200,000 Hours @ 85 °C (Statistical Life)
Termination Style
Faston
Unit Weight
0.05kg
Factory Pack Quantity
21 (MOQ = 105)
Datasheet