Search results for "텔레@upcoin24」:신용카드코인전송탈세하는방법"
-
SCT-F36-250, 0.333V, 250Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-250, 0.333V, 250Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-250 Technology Split Core AC Current Transformer Ratio 250/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 250Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F36-50, 0.333V, 50Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-50, 0.333V, 50Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-50 Technology Split Core AC Current Transformer Ratio 50/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 50Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's
Fastron Electronics SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-1000 Technology Split Core AC Current Transformer Ratio 1000/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 1000Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-800, 0.333V, 800Amp measurement Split Core CT's
Fastron Electronics SCT-F50-800, 0.333V, 800Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-800 Technology Split Core AC Current Transformer Ratio 800/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 800Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 800g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's
Fastron Electronics SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 600g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's
Fastron Electronics SCT-F50-500, 0.333V, 500Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-500 Technology Split Core AC Current Transformer Ratio 500/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 500Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 500g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-400, 0.333V, 400Amp measurement Split Core CT's
Fastron Electronics SCT-F50-400, 0.333V, 400Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-400 Technology Split Core AC Current Transformer Ratio 400/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 400Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
GT-D-A6-D-1, Signal Isolator/Conditioner, 4-20mA input, 22-60VAC/DC aux, 4-20mA output
Fastron Electronics GT-D-A6-D-1, Signal Isolator/Conditioner, 4-20mA input, 22-60VAC/DC aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number GT-D-A6-D-1 Control Output 4-20mA Input 4-20mA Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 22 - 60VDC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$219.00
$258.42 inclGST -
AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output
Current Transducer, AT-AAO(0-1)-A-1, AC Current Transducer, 1 Amp Average RMS, 100-240VAC/DC Aux, 4-20mA output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-AAO(0-1)-A-1 Control Output 4-20mA Average RMS Input 0-1 Amp Rms Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$209.00
$246.62 inclGST -
AT-AAO(0-1)-D-4, AC Current Transducer, Average RMS, 1 Amps, 22-60AC/DC Aux, 0-10V output
AT-AAO(0-1)-D-4, AC Current Transducer, Average RMS, 1 Amps, 22-60VAC/DC Aux, 0-10V output Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type) Each unit needs just 50mm x 120mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number AT-AAO(0-1)-D-4 Control Output 0-10V Average RMS Input 0-1 Amp Rms Over Range x 1.2 Operating Temperature 0 - 60°C Load Voltage 22-60VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$209.00
$246.62 inclGST -
SI01-5H55L00000000, Signal Isolator/Conditioner, 0-10V input, 20-60VAC/DC aux, 4-20mA output, Fixed zero and span
SI01-5H55L00000000 (SI-101-4-2-L), Signal Isolator/Conditioner, 0-10V input, 20-60VAC/DC aux, 4-20mA output, Fixed zero and span Fixed Zero and Span Setting 150mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number SI01-5H55L00000000 Control Output 4-20mA Input 0-10V Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 20-60VAC/DC Span Adjustment Range Fixed Zero Adjustment Range Fixed Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$169.00
$199.42 inclGST -
E62.F81-203D10, 20uF, 40x81mm Heavy Duty AC Film Power Capacitor w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC
E62.F81-203D20, 20uF, 40x81mm Heavy Duty AC Film Power Capacitor, D1 Design w/Stud -40 to 85 °C 200,000 hrs, 640VAC/1000VDC Characteristics and utility 20uF 640VAC/1000VDC Metalized Polypropylene Film Connector type - M6 x 12mm Studs M12 Stud mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E62.F81-203D10 Technology Metalized Polypropylene Film Capacitor Dimensions ø40x81mm Mounting M12 Stud Standards IEC 60831-1/2, EN 60831-1/2 Voltage 640VAC/1000VDC Operating Temperature Range -40 to 85 °C Capacitance 20uF Tolerance On Capacitance +10 / -10% Lifetime 200,000 Hours @ 85 °C (Statistical Life) Termination Style 4 x Faston Terminals Unit Weight 0.14kg Factory Pack Quantity 21 (MOQ = 105) Datasheet Product Datasheet
$87.50
$103.25 inclGST