Trent FGM6DC-2PL-320 80A, 2 Pole DC Moulded Case Circuit Breaker (MCCB) Fixed Type 20kA 80 Amp, 1000VDC
Miniature Circuit Breakers are used for over-current (overload and short-circuit) protection of installations and devices, and as a disconnector in case of electric shock
Features :
2 Pole Disconnect
20kA Short Circuit Rating @1000VDC
Suitable for DC Power Systems Including Solar and Battery
Standards :
IEC/EN 60947-3
IP20 (IP40 Installed) IEC 61008
Specification
Trent Part Number
FGM6DC-2PL-320 80A
Functions
2 Pole DC MCCB
Nominal Voltage
1000VDC
Nominal Current Range
80 Amps
Trip Delay Time
< 50ms
Rated Impulse Voltage
12kV
Operating Temperature
-35 to 70 Deg C
Electrical Operations
5,000 Ops
Insulation Voltage
1500V
Short Circuit Current Ics=Icu (Ics/Icu)
20kA
Approvals
CE
Standards
GB/T14048.2, IEC/EN 60947-3, IP20 (IP40 Installed)
Weight
2.2kg
Enclosure Material
UL94
Factory Pack Qty
1
Datasheet
Product Datasheet
CE Declaration
Fastron FRTD-PT100-50, Pt100 Air Temperature Sensor, 50mm shaft length, 77 x 77 x 55mm Body
4-20mA Output 2 Wire
Temp Measurement for 0 to 100 Deg C Max
190 x 18mm with 1M Cable
20 Second Response Time
12-30VDC Supply 150mA max
Pt100 Temp Sensing Elements
Specification
Fastron Part Number
FRTD-PT100-50
Sensor Type
RTD (Temperature) & Thin Film Capacitor (Humidity)
No of Wires
3
Shaft Length
190mm
Shaft Thickness
18mm
Approvals
CE, ROHS
Cable length
1 Meter
Temperature Range
0 to 100 Deg C
Mounting Style
Through Hole
Weight
45g
Factory Pack Qty
1
Datasheet
Datasheet
Installation Guide
Wiring Diagram
Current Transducer, AT-AA9-D-4, AC Current Transducer, Average RMS, 5 Amps, 24VDC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA8-D-4
Control Output
0-10V Average RMS
Input
0-5 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
24VDC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA9-D-1, AC Current Transducer, Average RMS, 10 Amps, 22-60VAC/DC Aux, 4-20mA output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-D-1
Control Output
4-20mA Average RMS
Input
0-10 Amp rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Current Transducer, AT-AA9-D-4, AC Current Transducer, Average RMS, 10 Amps, 22-60VAC/DC Aux, 0-10V output
Adjustable Zero and Span Setting
250mS Response Time
PC 94 UL V0
Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) or 0-10V/0-5V (For Direct Voltage Type)
Each unit needs just 50mm x 120mm depth DIN Rail cabinet space
Specification
Fastron Electronics Part Number
AT-AA9-D-4
Control Output
0-10V Average RMS
Input
0-10 Amp Rms
Over Range
x 1.2
Operating Temperature
0 - 60°C
Load Voltage
22 - 60VAC/DC
Span Adjustment Range
+/-10%
Zero Adjustment Range
+/-5%
Termination Style
Screw
Mounting Style
DIN Rail Mount
Case Material
PC - UL 94 V0
Weight
170g
Factory Pack Qty
1
Datasheet
Product Datasheet
Techsem MDK110-16-223F3, Dual Diode Module, Common Cathode, 110 Amp, 1600V, 22mm Package
Features
Pressure Contact Technology
Electrically insulated base plate
Industrial standard package
2900V Isolation
20mm Base Width
Applications
Power Supplies
Rectifier for drives applications
Uncontrolled Rectifiers
Deep Cycle Operation
Rectifiers for UPS
Battery Chargers
Specification
Techsem Part Number
MDK110-16-223F3
Vrrm
1600V
Diode Configuration
Dual Diode Module, Common Cathode
IF(av) @ 100 Deg C
110 Amp
Package Size
W:20mm L:93mm D:30mm
Itsm
2.6 kA
VF(to)
0.8V
Tj(max)
150°C
rF
1.74mΩ
Terminals
M5 Screw
Hole Centres
80mm (M6)
Gate Terminals
N/A
R th(j-c)
0.27°C/W
R th(c-h)
0.20°C/W
Weight
175g
Mounting Torque
4 Nm (4 Nm Terminals)
Factory Pack Qty
15
Certification
UL Listed
Techsem Headquarters
China
Datasheet
Product Datasheet
Alternatives
See VSKC91/14 for Solder Contact alternative of Contact Us for Possible Replacement for alternative part
VA1021B, Liquid PH Tester & Temperature Tester Portable with External BNC Connected Sensor. Range 0-14PH, 0-50 Deg C Accuracy 0.02PH/0.5 Deg C, WITH BLUETOOTH AND APP
Features
Portable /Battery Powered 3 x AAA (500 Hours)
External Sensor (BNC)
Range 0-14PH, 0-50 Deg C
Accuracy 0.02PH/0.5 Deg C
Bluetooth Comms
Free App
Specification
Datasheet
Datasheet
VAT810, CO2 Indoor Air Quality Monitor. Desktop Mount, 5VDC Supply (1.5W). Temperature Measurement Range -20 to 50 Deg C Accuracy +/-0.5 Deg C. Humidity 0-100% +/-3%RH, CO2 300-3000ppm +/-(50ppm + 3%). With Sound and Light Alarm, Modbus RS485
Features
Desktop Mount
5VDC Supply (1.5W)
Temperature Measurement Range -20 to 50 Deg C Accuracy +/-0.5 Deg C Humidity 0-100% +/-3%RH
CO2 300-3000ppm +/-(50ppm + 3%)
With Sound and Light Alarm
Capacitive Humidity Sensor
NDIR CO2 sensor
IP40
125x85x30mm
Touch Key Operation
Specification
Datasheet
Datasheet
LEM CD 100-S/SP5, O/L Hall Effect Current Sensor, 2 x 1000 Amp, +/-5V Output
Features
Bandwidth DC to 5kHz
Closed loop transducer using Hall effect (Compensated)
Compact and versatile
Panel mounting-Horizontal or Vertical
Insulated plastic case recognized according to UL 94-V0
Advantages
Very good linearity
Very good accuracy
Low temperature drift
Wide frequency bandwidth
Very low insertion losses
High immunity to external interference
Current overload capability
Low power consumption
Applications
Single or 3 Phase Inverter
Propulsion and Breaking Chopper
Propulsion Converter
Auxiliary Converter
Railway Security System
Specification
LEM Part Number
CD100-S/SP5
Technology
Closed Loop Hall Effect
Aperture
ø40mm
ROHS
Yes
Supply Voltage
+/-15 VDC Bipolar, Isolated
Load Current (RMS + DC)
2 x1000 Amp
Output
+/-5 V
Isolation
6 kV
Bandwidth
DC-5 kHz
Mounting Style
Panel Mount
Operating Temperature Range
-10°C / 80°C
Accuracy
2.5%
Unit Weight
1kg
Factory Pack Quantity
10
Datasheet
Product Datasheet
Application Notes
LEM Applications Manual 3rd Edition
Electronicon 275.166-804800, 12.5kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 95 x 230(+32 +5/-2)mm Gas Filled, 3 x 48.1uF
Characteristics and utility
12.5kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.166-804800
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
95 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
12.5 Kvar
Capacitance
3 x 48.1uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 13.7 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.6kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage
Power Factor Correction Blog
Electronicon 275.546-703800/221K02, 10kvar 525V 50Hz, Power Factor Correction Capacitor, 3 Phase, 75 x 230(+32 +5/-2)mm Gas Filled, 3 x 38.5uF
Characteristics and utility
10kVar @ 525V @ 50 Hz 10.0kvar 10kvar
Three phase capacitor DUAL WINDING internally delta connected
Discharge resistors Incorporated
Reactive power factor correction
Gas Filled Lightweight Construction
Connector type - single sided terminal
Indoor mounting
Triple safety
Overpressure disconnection system
Protection by internal fuses
Self Healing
Construction and materials
Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ
Aluminium case with bottom fixing M12x16
Standards
IEC 60831-1/2
EN 60831-1/2
Specification
Electronicon Part Number
275.546-703800/221K02
Technology
Gas Filled, Low Loss, Self Healing
Dimensions
75 x 230(+32)mm
Standards
IEC 60831-1/2, EN 60831-1/2
Voltage
525V @ 50Hz
Kvar
10 Kvar
Capacitance
3 x 38.5uF
Tolerance On Capacitance
-5% + 10% (others on request)
Current (In)
3 x 11 Amp
Overpressure Disconnection System
YES
Self Extinguishing Resin
YES
Internal Fuses
YES
Self Healing
YES
Mounting
M12 x 16mm (Indoor)
Operating Temperature Range
50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs)
Lifetime
120,000 Hours
Termination Style
Filter Type Terminal
Approvals
UL 810, CSA C22.2 No.90
Unit Weight
1.6kg
Factory Pack Quantity
30
Datasheet
Product Datasheet
Application Notes
Discharge Resistor Usage