Search results for "선불유심20만원 Gora43430aa 휴대폰미납소액대출 고라통신 선불유심 현금화 정식업체 저신용자비상금소액대출 청송군 24시 당일소액급전대출"
-
KNL630-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 630 Amps, 240VAC Coil
Heavy Item - No free ShippingIskra Doo KNL630-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 630 Amps, 240VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL630-00-240VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 630 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional G350 Snap On (2NO + 1NC or 1NO + 2NC) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 90W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 17kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
GX11BAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 12VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67, IP69K
Free Aus Post Shipping for $300 SpendGigavac Contactor GX11BAB, Contactor SPST-NO, 150+ AMP, 12-800VDC, 12VDC Coil Features Hermetically Sealed (Patented) rated to 175 Deg C UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 & IP69K SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48,72,120VDC, or 120,240VAC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Chassi level power terminals Salt Fog MIL-STD-810 Specification Gigavac Part Number GX11BAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.2kV rms Control Input Terminals 38cm Flying Leads Special Feature Hermetically Seal rated to 175 Deg C Mounting Style Panel Mount (M5) Load Voltage Range 12-800VDC Standards UL1604, IP67, IP69K, SAE J1171, ISO8846 Termination Style M8 Unit Weight 440g Factory Pack Qty 1 Datasheet Product Datasheet
-
AKR 50 C420L, AC Current Sensor, selectable 10, 20, 50 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 10, 20, 50 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 50 C420L, Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 10,20,50 Amp Selectable Maximum Measurement Current (Peak) 17,34,85 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
DRA1-CMXE100D6, Solid State Relay, 20-28VDC Control, 6 Amp, 0-100VDC Load, Din Rail
Free Aus Post Shipping for $300 SpendCrydom DRA1-CMXE100D6, Solid State Relay, 20-28VDC Control, 6 Amp, 0-100VDC Load, Din Rail Features Ratings from 3A to 20 Amp @ 60-200VDC DIN Rail Mount Mosfet output for reliable DC switching Multiple modules can be wired in parallel for higher currents UL/CSA/VDE Approved, CE Compliant to EN60950-1 Redesigned housing with anti-rotation barriers EMC compliant to Level 3 Epoxy free design Spec Crydom Part Number DRA1-CMXE100D6 Switching Type DC Load ROHS Yes (Details) Control Voltage 20-28VDC Load Current 6 Amp DC Surge Capability (10ms) 100 Amp DC Special Feature LED Status Indicator Mounting Style DIN Rail Mount Load Voltage Range 0 - 100VDC EMC Compliant Level 3 Termination Style Screw Unit Weight 11g Factory Pack Qty 20 Datasheet Product Datasheet Equivalent Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement Heatsink SSR and Heatsink Assemblies
-
GV241MAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 12/24VDC PWM Rated Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67
Free Aus Post Shipping for $300 SpendGigavac GV241MAB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 12/24VDC PWM Rated Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV241MAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12/24VDC PWM Rated Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 100 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
-
LT 4000-T C/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +/-24VDC Supply, 10mm Bubsar Mount, X = 0.5%
Free Aus Post Shipping for $300 SpendLEM LT 4000-T C/L Hall Effect Current Sensor, Ipn = 4000 Amp, Isn = 800mA, +/-24VDC Supply, 10mm Bubsar Mount, X = 0.5% Features Bipolar and insulated current measurement up tp 6000 Amp Current output Bandwidth DC to 100kHz Closed loop (compensated) current transducer Panel mounting Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity High accuracy Low offset drift over temperature Wide frequency bandwidth Very low insertion losses High immunity to external interference Current overload capability Low power consumption Applications Windmill Inverters Test and Measurement Substations AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications Application Domain Industrial Standards EN 50178:1997 IEC61010-1:2010 UL 508:2010 Specification LEM Part Number LT 4000-T Technology Closed Loop Hall Effect Aperture No Aperture ROHS Yes Supply Voltage +/- 15 VDC to +/- 24 VDC Bipolar, Isolated Load Current (RMS + DC) 4000 Amp Measurement Range +/- 6000 Amp Output 800 mA Isolation 6 kV Bandwidth DC-100 kHz Mounting Style Busbar Mount Operating Temperature Range -10°C / 85°C Accuracy 0.5% Termination Style M5 threaded studs Unit Weight 12.1kg Factory Pack Quantity 1 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FRS 2500-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version
LEM FRS 2500-SUIH, O/L Coreless Current Transducer, 2500 Amp, +12V...24VDC Supply, 111.4 x 18.7 Square Aperture, 4-20mA Unipolar Output, Traction Version Features Bandwidth DC to 1000kHz Open loop transducer using Coreless Hall effect Technology Compact and versatile Panel mounting-Horizontal or Vertical Insulated plastic case recognized according to UL 94-V0 Advantages Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses Low power consumption Applications Wind Turbines Electrolyser AC variable speed drives and servo motor drives Static converters for DC motor drives Battery supplied applications Uninterruptible Power Supplies (UPS) Switched Mode Power Supplies (SMPS) Power supplies for welding applications. Specification LEM Part Number FRS 2500-SUIH Technology Open Loop Coreless Hall Effect Aperture 111.4 x 18.7mm Square ROHS Yes Supply Voltage +12...24VDC, Isolated Load Current (RMS + DC) 2500 Amp Measurement Range +/-7500 Amp Overload Rating N/A Output 4-20mA Unipolar Isolation 18.5 kV Bandwidth DC-1000 kHz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style Molex 5045-04A Unit Weight 1500g Factory Pack Quantity 4 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
$529.00
$624.22 inclGST -
ITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +/-24V Supply
Free Aus Post Shipping for $300 SpendITL 4000-S High Precision Hall Effect Current Sensor, 4000 Amp, 1600mA Output, 268mm Aperture, +/-24V Supply Datasheet Product Datasheet
-
P105FDA, MiniTactor Contactor SPST-NO, 50 AMP, 1200VDC, 48VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals
Free Aus Post Shipping for $300 SpendGigavac P105FDA, MiniTactor Contactor SPST-NO, 50 AMP, 1200VDC, 48VDC Coil, M3 Coil Screw Terminals, M4 Power Terminals Features Perfect for Photovoltaic/Battery Systems Hermetically Sealed (Patented) rated to 175 Deg C High Efficiency Dual DC Coils - 12,24,48VDC options Ideal for battery powered systems or where low power is needed Built in Coils suppression for all DC Coils Small and lightweight Flexible package for installation Chassi level power terminals Specification Gigavac Part Number P105FDA Main Contact Type SPST-NO Auxiliary Contact Type N/A Coil Voltage 48VDC Load Current 50 Amp Mechanical Life @ 0 Amp 100,000 Operations Dielectric at Sea Level 4.3kV rms Control Input Terminals M3 Screw Special Feature N/A Mounting Style Panel Mount (M4) Load Voltage Range 1200VDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style M4 Screw Unit Weight 135g Factory Pack Qty 1 Datasheet Product Datasheet
-
TGLW26-1023315, 3 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
Free Aus Post Shipping for $300 SpendTGLW26-1023315, 3 Pole Rotary Switch BLACK, 315 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary Load Break or Disconnect Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the use Features : 400VAC in various Ratings 1 Pole Momentary 64mm x 64mm Cutout Standards : IP40 IEC60947-5-1 CE Specification TRENT Part Number TGLW26-1023315 Functions 3 Pole AC Disconnect Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 315Amp @400VAC Rated Insulation Voltage 690VAC Humidity 35-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 4kg Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
-
N3175HE180, Thyristor(SCR) PUK 2150 Amp, 1800V, 101/35
Free Aus Post Shipping for $300 SpendWestcode-IXYS-Littlefuse N3175HE180, Thyristor(SCR) PUK 2150 Amp, 1800V, 101/35 Features Very low forward voltage drop Very low leakage current International standard package 101/35 Package Press Mounted Double or Single Sided Cooling Applications Power Supplies Rectifier for drives applications Uncontrolled Rectifiers Rectifiers for UPS Battery Chargers Field Supply for DC Motors Water Cooled Rectifiers DC Substation Blocking Diode Large Generators Specification Westcode IXYS Part Number N3175HE180 Vrrm 1800V Diode Configuration Thyristor Capsule (PUK) IF(av) @ 85 Deg C 2150 Amp Package Size ø101 x 35mm Itsm 44 kA VF(to) 0.90V Tj(max) 125°C rF 0.106mΩ Gate Terminals Faston 4.8 x 0.8mm & 2.8 x 0.8mm R th(j-c) (double sided cooled 180°sin) 0.0125°C/W R th(c-h) (double sided cooled) 0.003°C/W Weight 900g Clamping Force 30 - 65kN Factory Pack Qty 12 Certification ROHS IXYS Headquarters Germany Datasheet Product Datasheet Alternatives t2180n18tof-vt Heatsink Heatsink Profiles
-
G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version
Free Aus Post Shipping for $300 SpendGigavac G22WP, HV Relay, 15kV, 50A, SPDT-CO, 24VDC Coil, 1,000,000 Cycles, 17kV Isolation, Screw Terminals, Panel Mount Version Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coils Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G22WP Main Contact Type SPDT-CO (1 x CO Contacts) Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 50 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Impulse Withstand 30kV rms Control Input Terminals M6 Mounting Style Panel Mount (M4) Load Voltage Range 15kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 84g Factory Pack Qty 1 Datasheet Product Datasheet