MI450; Pt100; 0..150 Deg C; 4-20mA; 3; A240V;2;L, Temperature Programable Transducer, Class 1, Pt100 0-150 Deg C, 4-20mA Output, 3 Wire, 240VAC, RS232 Comms, Linear Output
Free Aus Post Shipping for $300 spendIskra Doo MI450; Pt100; 0..150 Deg C; 4-20mA; 3; A240V;2;L, Temperature Programable Transducer, Class 1, Pt100 0-150 Deg C, 4-20mA Output, 3 Wire, 240VAC, RS232 Comms, Linear Output Class 1 (EN 60688) Programable DC Voltage Output 0-1V to 0-10V @ 20mA Programmable DC Current Output 0-1mA to 0-5mA, 0-5mA to 0-20mA @ 15V Features : Measurement of up to 500VAC Universal Supply 20 - 300VDC/40 to 276VAC 40 to 70Hz Accuracy class 1 Input frequency 40-70Hz Specification Iskra Doo Part Number MI450; Pt100; 0..150 Deg C; 4-20mA; 3; A240V;2;L Functions Programmable Temperature Transducer Supply Voltage 240VAC +/-20% Nominal Measurement Range 0-150 Deg C (pt100) Maximum Measurement Range 0-150 Deg C (pt100) Output 4-20mA Accuracy Class 1 Isolation 3.5kV Comms N/ Weight 340g Enclosure Material UL94 Factory Pack Qty 1 EU Directives N/A Safety Protection Class II 600V rms, installation category II 300V rms, installation category III Pollution Degree 2 in compliance with SIST EN 61010-1:2002 Enclosure Material PC/ABS non combustable-self-extinguishability, complying with UL 94 V-0 Enclosure Protection IP20 Shock Withstand 300g 8ms Pulse . 6 Shocks in each of 3 axes Vibration Withstand 0.7g, 3...100Hz, 1oct/min 10 cycles in each of three axes Operating Temperature -20 →+70 °C Datasheet Product Datasheet
-
DTC1-A/M1-2I, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, 24VAC/DC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M1-2I, DIN Rail Mount Temperature/Humidity Controller with Dehumidification Function, Multirange Thermocouple Input, Pt100 Input Jumper Setting, 24VAC/DC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M1-2I Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options Dual Input Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 24VAC/DC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
MCT 400/5 Class 0.5 5VA 62-30 (40), Series Current Transformer, Revenue Grade
Secure MCT 400/5 Class 0.5 5VA 62-30 (40), Series Current Transformer, Revenue Grade Features DIN Rail Mounting Clip Included Built In Sealable Terminal Covers Mounting Feet Supplied Narrow Width (45mm) Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Secure Part Number MCT 400/5 Class 0.5 5VA 62-30 (40) Technology AC Current Transformer Ratio 400/5 Aperture Size ⌀ 26mm or 34x10mm Busbar VA Rating 15VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Din Rail Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) Ipn x 1.2 Termination Style Screw Certifications CE / ILAC Certified for Billing Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet
$129.00
$152.22 inclGST -
DTCA1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-20mA Input, 85-265VAC, 4-20mA Output
Fastron DTCA1-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-20mA Input, 85-265VAC, 4-20mA Output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTCA1-A/M-TR Transmitter Output 4-20mA Input 0-20mA Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
MCBC2450DF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 4-20mA Input, 10 Cycles
Free Aus Post Shipping for $300 SpendCrydom MCBC2450DF, Solid Sate Relay based Burst Fire Controller, 240VAC, 50 Amp, 4-20mA Input, 10 Cycles Features Selectable Proportional Burst Control Input Ratings from 25A to 90 Amp @ 180-530 VAC SCR output for heavy industrial loads Zero voltage turn-on outputs UL/CE/ROHS Compliant Direct bond copper substrate Direct power lead frame Epoxy free design Spec Crydom Part Number MCBC2450DF Switching Type Burst Fire (10 Cycles) ROHS/CE/UL Yes Control Voltage 4 - 20mA Proportional Input Requires DC Power Supply Load Current 50 Amp (rms) Surge Capability 625Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 180-280VAC Overvoltage Vpk 600V Termination Style Terminal Plug & Screws Unit Weight 87g Factory Pack Qty 10 Datasheet Product Datasheet Notifications Please note Changes from Gen 3 to Gen 4 (current) package design here Equivalent Crydom PMP2450W or Contact Us for Possible Replacement App Notes Why Use SSR's? The inside story Selecting a SSR DC Output SSR's Selecting a Suitable Heatsink Use of Thermal Interface Material How to Verify the Proper Heatsink Effect of Forced Air Cooling Fuse Protection of SSR's Overvoltage Protection "P" Option MOV SSR Reliability Whitepaper 3 Phase Motors and Heating Applications 3 Phase Motor Reversing How to test a SSR SSR Precautions SSR Life Expectancy MTBF ROHS & Reach Statement
-
AKR 5 C420L, AC Current Sensor, selectable 2, 5 Amp, True RMS 4-20mA output, 19mm round aperture
Free Aus Post Shipping for $300 SpendLEM AKR Series True RMS Solid Core AC Current Sensor with Process Outputs Compact and versatile Solid Core AC current sensor, selectable 2 or 5 Amp True RMS. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Solid Core True RMS output 4-20mA current output Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for cable up to ⌀19mm High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number AK 5 C420L Technology AC Current Transformer with Process Output ROHS Yes Supply Voltage 24VDC Loop Powered Nominal Current (RMS + DC) 2, 5 Amp Selectable Maximum Measurement Current (Peak) 3.4, 10.1 Amp Output 4-20mA True RMS Aperture ⌀19mm Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
KNL18-01-240VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 240VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps
Free Aus Post Shipping for $300 SpendIskra Doo KNL18-01-240VAC AC Contactor 240/400/500/690V, Overload 144(10s), 170(5s), 200(1s), 500(0.001s) (each pole), 240VAC Control Voltage, 4 Pole 3 x NO, 1 x NC Nominal Current = 18 Amps Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL18-01-240VAC Functions 4 Pole Contactor with Aux contacts Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 18 Amp Continuous @ 55 Deg C Overload Capability 144(10s), 170(5s), 200(1s), 500(0.001s) Auxiliary Contacts 3 x NO, 1 x NO Trip Delay Time 2-10ms Electrical Life 200,000 Ops Operating Temperature -25 to 40 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 240VAC Power Dissipation 0.36W Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 200g Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
DTCV5-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-5V Input, 85-265VAC, 4-20mA Output
Fastron DTCV5-A/M-TR, DIN Rail Mount Process Transmitter with Alarm Function, 0-5V Input, 85-265VAC, 4-20mA Output Filter Time Constant Function Converter function 2 Input 1 Output, and 1 Input Two Output Versions available 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTCV5-A/M-TR Transmitter Output 4-20mA Input 0-5V Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options None Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
$209.00
$246.62 inclGST -
Rish Xmer 155/80 3000/5 SCCT Class 1 45VA Series Split Core Current Transformer
Heavy Item - No Free ShippingRishabh Xmer CT Split 155/80 3000/5 SCCT Class 1 45VA Series Split Core Current Transformer Features Quick Release Split Core System Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 155/80 3000/5 SCCT Class 1 45VA Technology Split Core AC Current Transformer Ratio 3000/5 Aperture Size 85 x 120mm VA Rating 45VA Accuracy Class Class 1 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 3000Amp x 1.2 Termination Style Screw Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet
-
DC-0-100-420-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA Unipolar output, 24VDC supply
DC-0-100-420-1.0, Hall Effect DC Current Transducer, 0-100 Amp DC, 4-20mA Unipolar output, 24VDC supply Compact and versatile Split Core DC current sensor, 0-100 Amp DC, 4-20 mA Unipolar Output Other measurement ranges available on request Features ⌀20mm Aperture DC Unipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number DC-0-100-420-1.0 Technology DC Hall Current Sensor with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) 0-100 Amp Response Time < 1uS Output Unipolar 4-20mA Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Terminals Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$385.00
$454.30 inclGST -
FWBV414H29-50AC-010, AC Voltage Transducer, 0-50V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request)
Fastron Electronics FWBV414H29-50AC-010, AC Voltage Transducer, 0-50V AC input, 100-240VAC/DC aux, 4-20mA Average RMS output, 50/60Hz (25Hz - 1kHz Available on Request) Adjustable Zero and Span Setting 250mS Response Time PC 94 UL V0 Input signals can be converted to insulated 4 to 20 mA DC output (for direct current output type) Each unit needs just 22.5 x 114 mm depth DIN Rail cabinet space Specification Fastron Electronics Part Number FWBV414H29-50AC-420 Control Output 4-20mA Average RMS Input 0-50VAC, 50/60Hz (25Hz - 1kHz Available on Request) Over Range x 1.5 Operating Temperature 0 - 60°C Load Voltage 100-240VAC/DC Span Adjustment Range +/-10% Zero Adjustment Range +/-5% Termination Style Screw Mounting Style DIN Rail Mount Case Material PC - UL 94 V0 Weight 170g Factory Pack Qty 1 Datasheet Product Datasheet
$269.00
$317.42 inclGST -
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-300-420B-24, Hall Effect DC Current Transducer, +/-300 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00