Search results for "텔레@CASHFILTER365「:업비트코인추적테더트론매입"
-
SCT-F16-100-50mA-2M, 50mA, 100Amp Measurement, Class 1 Split Core Current Transformer, Special model with 2m Cable length
Fastron Electronics SCT-F16-100-50mA-2M, 50mA, 100Amp Measurement, Class 1 Split Core Current Transformer, Special model with 2m Cable length Features Quick Release Split Core System Cable Mount 50 mAmp Output Self Powered Rated System Voltage 0.60/3kV 0.5M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F16-100-50mA Technology Split Core AC Current Transformer Ratio 100/50mA Aperture Size ø 15 mm VA Rating N/A Accuracy Class Class 0.5 Output 50 mAmp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 100Amp x 1.2 Termination Style 0.5M Flying leads Unit Weight 100g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$58.00
$68.44 inclGST -
TGLW30-4D100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1
TGLW30-4D100, 4 Pole Rotary/CAM Switch RED, 100 Amp 400VAC, Plastic, Direct Type, IEC60947-5-1 Rotary CAM Switches are used to Isolate or Switch under load. Widely Used for Rugged Industrial Applications Including Critical Machinery requiring safe operation by the user. Features : 400VAC in various Ratings 4 Pole 2 Postion 64mm x 64mm Cutout Standards : IP40 Front, IP20 Terminals IEC 60947-1,-3 IEC 60204 Specification TRENT Part Number TGLW30-4D100 Functions 4 Pole AC Disconnect CAM Switch Nominal Voltage 400VAC @ 50/60Hz Rated Impulse Voltage 6kV Nominal Current Range AC 100 Amp @400VAC Rated Insulation Voltage 690VAC Humidity 10-85% Approvals CE Standards IEC 60947-1,-3, IEC 60204, IP20 (IP40 Installed) Weight 470g Enclosure Material UL94V0 Factory Pack Qty 1 TRENT(Fastron) Head Office Australia Datasheet Datasheet
$119.60
$141.13 inclGST -
XY12038HBL 230VAC, AC FAN 120mm sq X 38mm 230V, 32 Watts, 94CFM, 2600-3000RPM Ball bearing, CE Approved
XY12038HBL 230VAC, AC FAN 120mm sq X 38mm 230V, 32 Watts, 94CFM, 2600-3000RPM Ball bearing, CE Approved Datasheet Product Datasheet
$28.75
$33.93 inclGST -
GV244FPB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, PCB MOUNT, SPST-NO Auxiliary Contact, IP67
Gigavac GV244FPB, Contactor SPST-NO, 400+ AMP, 100-800VDC, 48VDC Coil, PCB MOUNT, SPST-NO Auxiliary Contact, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV244FPB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 48VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals PCB Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 100 - 800VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
$265.00
$312.70 inclGST -
KM01.1105.11, IEC Appliance Inlet C14 with 2 Pole Switch and Fuse
Schurter KM01.1105.11, IEC Appliance Inlet C14 with 1 Stage EMC (RFI) Line Filter, Switch and Fuse Features Panel Mount : Screw-on mounting from front side 4 Functions : Appliance Inlet Protection class I, EMC Line Filter 1 Stage, Line Switch 2-pole, Fuseholder for fuse-links 5 x 20 mm 2-pole Line filter in standard and medical version Quick connect terminals 6.3 x 0.8 mm Characteristics Compact design with optimal shielding All single elements are already wired Plug removal necessary for fuse-link replacement With EMC-shield Suitable for use in equipment according to IEC/UL 60950 Suitable for use in medical equipment according to IEC/UL 60601-1 Medical Version M80 Specification Schurter Part Number KM01.1105.11 Rated Voltage 250V Rated Current 10A Filter Stages N/A Operating Temperature -25°C to 85°C Filter Type N/A Fuse Holder 2 Pole Line Switch 2 Pole Mounting Panel Mount - Case 50 Material Nickel Plated Steel Termination Style C14/Faston Weight 30g Factory Pack Qty 1 Protection Class From front side IP 40 acc. to IEC 60529 Isolation 1.7kV VDE/UL/CSA/ROHS Yes Datasheet Product Datasheet
$39.00
$46.02 inclGST -
E62.M10-603S20, 60uF Heavy Duty AC Film Capacitor ø75 x 105mm, M5x12 terminals. S2 Design, 680VAC/1120VDC
E62.M10-603S20, 60uF Heavy Duty AC Film Capacitor ø75 x 105mm, M5x12 terminals. S2 Design, 680VAC/1120VDC Characteristics and utility 60uF 680VAC/1120VDC Metalized Polypropylene Film Connector type - M6 x 12mm Studs M12 Stud mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E62.M10-603S20 Technology Metalized Polypropylene Film Capacitor Dimensions ø75 x 105mm Mounting M12 Stud Standards IEC 60831-1/2, EN 60831-1/2 Voltage 680VAC/1120VDC Operating Temperature Range -40 to 85 °C Capacitance 60uF Tolerance On Capacitance +10 / -10% Lifetime 200,000 Hours @ 85 °C (Statistical Life) Termination Style M6 x 12 studs Unit Weight 1.1kg Factory Pack Quantity 21 (MOQ = 105) Datasheet Product Datasheet
$225.00
$265.50 inclGST -
FESCT-055-200-5-IP65, 200Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture
Fastron Electronics FESCT-055-200-5-IP65, 200Amp Measurement, 5 Amp Output Split Core CT's, Class 1, w/10M Flying leads, ø 55mm Aperture Features Quick Release Split Core System 10m Flying Leads ø 55mm Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurement, 5 Amp Outputs Specification Fastron Electronics Part Number FESCT-055-200-5-IP65 Technology Split Core AC Current Transformer Ratio 200/5A Aperture Size ø 55mm VA Rating 2.5VA Accuracy Class Class 1 Output 5 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Dimensions 180x138x52mm Mounting Style Panel Mount Operating Temperature Range -35°C / 55°C Continuous Current (max) 200Amp x 1.2 Termination Style 10M Twisted Pair 0.34mm^2 Unit Weight 2000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$465.00
$548.70 inclGST -
FESCT-075-800-1-IP65, 800Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, w/10M Flying leads, ø 75mm Aperture
Fastron Electronics FESCT-075-800-1-IP65, 800Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, w/10M Flying leads, ø 75mm Aperture Features Quick Release Split Core System 10m Flying Leads ø 75mm Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurement, 1 Amp Outputs Specification Fastron Electronics Part Number FESCT-075-800-1-IP65 Technology Split Core AC Current Transformer Ratio 800/5A Aperture Size ø 75mm VA Rating 7.5VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Dimensions 180x138x52mm Mounting Style Panel Mount Operating Temperature Range -35°C / 55°C Continuous Current (max) 800Amp x 1.2 Termination Style 10M Twisted Pair 0.34mm^2 Unit Weight 2000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$517.00
$610.06 inclGST -
FESCT-075-1000-1-IP65, 1000Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, 7.5VA, w/10M Flying leads, ø 55mm Aperture
Fastron Electronics FESCT-075-1000-1-IP65, 1000Amp Measurement, 1 Amp Output Split Core CT's, Class 1, 7.5VA, 7.5VA, w/10M Flying leads, ø 55mm Aperture Features Quick Release Split Core System 10m Flying Leads ø 75mm Mounting Feet Supplied Self Powered Rated System Voltage 0.60/3kV Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurement, 1 Amp Outputs Specification Fastron Electronics Part Number FESCT-075-1000-1-IP65 Technology Split Core AC Current Transformer Ratio 1000/5A Aperture Size ø 75mm VA Rating 7.5VA Accuracy Class Class 1 Output 1 Amp (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Dimensions 180x138x52mm Mounting Style Panel Mount Operating Temperature Range -35°C / 55°C Continuous Current (max) 1000Amp x 1.2 Termination Style 10M Twisted Pair 0.34mm^2 Unit Weight 2000g Factory Pack Qty 9 Datasheet Product Datasheet Application Notes Installation Guide
$517.00
$610.06 inclGST -
SCT-F36-150, 0.333V, 150Amp Measurement, Class 1 Split Core CT's Class 1, 35mm Aperture
Fastron Electronics SCT-F36-150, 0.333V, 150Amp measurement Split Core CT's Class 1, 36mm Aperture Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F36-150 Technology Split Core AC Current Transformer Ratio 150/0.333V Aperture Size ø 35 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 150Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 400g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$66.50
$78.47 inclGST -
SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's
Fastron Electronics SCT-F50-1000, 0.333V, 1000Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-1000 Technology Split Core AC Current Transformer Ratio 1000/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 1000Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 1000g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST -
SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's
Fastron Electronics SCT-F50-600, 0.333V, 600Amp measurement Split Core CT's Features Quick Release Split Core System Cable Mount 0.333V Output Self Powered Rated System Voltage 0.60/3kV 0.9M Flying Leads Applications US Based Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Fastron Part Number SCT-F50-600 Technology Split Core AC Current Transformer Ratio 600/0.333V Aperture Size ø 50 mm VA Rating N/A Accuracy Class Class 1 Output 0.333V (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Cable Mount/Busbar Mount Operating Temperature Range -15°C / 45°C Continuous Current (max) 600Amp x 1.2 Termination Style 0.9M Flying leads Unit Weight 600g Factory Pack Qty 9 Datasheet Product Datasheet Stocked Split Core CT's Listing Application Notes Installation Guide Types of Current Transformers - Blog Cable Losses and CT's High Accuracy or High Burden Requirements for CT's
$110.55
$130.45 inclGST