Search results for "텔레:bpmc55~~성인약국위고비처방방법"
-
FC5-L-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output
Fastron FC5-L-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Fastron Part Number FC5-L-1A-2-G-4 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 96x96mm with SSR/Relay output) Mounting Style 96x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output
Fastron FC5-S-1A-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x48mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-1A-2-G-4 Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$137.00
$161.66 inclGST -
FC5-H-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output
Fastron FC5-H-1U-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-1U-1-G-2-C Control Output 0-10V Input Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 48x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$217.00
$256.06 inclGST -
FC5-S-R-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output
Fastron FC5-S-R-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-S-R-2-T/R-2 Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4) Input Multirange Type,K,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x48mm with SSR/Relay output) Mounting Style 48 x 48mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet Datasheet User Manual Modbus Protocol FC5 Communication Protocol
$207.00
$244.26 inclGST -
FC5-H-W-1-G-2-C, 100-240VAC PID Controller with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output
Fastron FC5-H-W-1-G-2-C, 100-240VAC PID Controller with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm,Relay + 12VDC Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Specification Fastron Part Number FC5-H-W-1-G-2-C Control Output Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)/12VDC @ 20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 48x96mm with SSR/Relay output) Mounting Style 48x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Approvals CE Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$217.00
$256.06 inclGST -
FC5-L-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output
Fastron FC5-L-1A-1-G-2-C PID Controller, 100-240VAC with 1 Alarm, RS485, E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,4-20mA Output 4-digit displays (0.5s response) Drip-proof / Dust-proof IP66 (front panel only) Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available Each unit needs just 75 mm depth panel space Fastron Part Number FC5-L-1A-1-G-2-C Control Output 4-20mA Input Multirange Type,K,E,J, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V Option 1 1 Alarm, RS485 standard (Excludes 96x96mm with SSR/Relay output) Mounting Style 96x96mm Panel Mount Supply Voltage 100 - 240VAC +/-10% Termination Style Screw Sampling Time 100ms Weight 150-270g Factory Pack Qty 10 Datasheet & User Manual Datasheet User Manual FC5 Communication Protocol
$235.00
$277.30 inclGST -
KZL-060-010-02D2, Single Phase Diode Rectifier Bridge, Switchable, 0.6Amp, 600V, for Uin max 270VAC rms
KZL-060-010-02D2, Single Phase Diode Rectifier Bridge, Switchable, 0.6Amp, 600V, for Uin max 270VAC rms Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Part Number KZL-060-010-02D2 AC Line voltage 333V Device Configuration Phase Diode Rectifier Bridge DC Output @ 85 Deg C 0.6 Amp Package Size W13 x L:33 x H:23mm, 40mm Hole centers (Overall Length 46mm) Itsm 750 A VF(to) 0.85V Tj(max) 150°C rF 11mΩ Terminals M5 (5Nm) Switching Terminals screw Weight 150g Isolation 3kV Factory Pack Qty 10
$45.00
$53.10 inclGST -
SQL50A 1000V, 3 Phase Diode rectifier Bridge, 50 Amp @ TC = 55 Deg C, 35 Amp @ Tc = 85 Deg C, 1000V
SQL50A 1000V, 3 Phase Diode rectifier Bridge, 50 Amp @ TC = 55 Deg C, 35 Amp @ Tc = 85 Deg C, 1000V Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Part Number SKB 35/16 AC Line voltage 533V Device Configuration Three Phase Diode Rectifier Bridge DC Output @ 62 Deg C 25 Amp Package Size W:55mm L:45mm D:24mm Itsm 380 A VF(to) 0.85V Tj(max) 150°C rF 12mΩ Terminals Faston (6.3mm) Hole Centres Single M5 Gate Terminals N/A R th(j-c) 9.3°C/W R th(c-h) 0.9°C/W Weight 22g Isolation 3kV Factory Pack Qty 10 Datasheet Product Datasheet Alternatives See PSD51/18 for higher rated equivalent
$25.00
$29.50 inclGST -
E62.R17-124C60, 120uF, AC Film Capacitor ø116 x 176mm, M6x12 terminals with Bushing. C6 Design. Optimized For High RMS Currents, Voltage: 2000VDC/1200VAC
E62.R17-124C60, 120uF, AC Film Capacitor ø116 x 176mm, M6x12 terminals with Bushing. C6 Design. Optimized For High RMS Currents, Voltage: 2000VDC/1200VAC Characteristics and utility 120uF 1200VAC/1680VDC Metalized Polypropylene Film Connector type - M6 x 12mm Studs M12 Stud mounting Standards IEC 60831-1/2 EN 60831-1/2 Specification Electronicon Part Number E62.R17-124C60 Technology Metalized Polypropylene Film Capacitor Dimensions ø116 x 176mm Mounting M12 Stud Standards IEC 60831-1/2, EN 60831-1/2 Voltage 1075VAC/1680VDC Operating Temperature Range -40 to 85 °C Capacitance 120uF Tolerance On Capacitance +10 / -10% Lifetime 200,000 Hours @ 85 °C (Statistical Life) Termination Style M6 x 12 studs Unit Weight 2kg Factory Pack Quantity 21 (MOQ = 105) Datasheet Product Datasheet
$441.00
$520.38 inclGST -
SKD 31/16, Three Phase Diode rectifier Bridge, 44 Amp, 1600V replaces Powersem PSD25T/16
SKD 31/16, Three Phase Diode rectifier Bridge, 31 Amp, 1600V replaces Powersem PSD25T/16 Features Package with DCB ceramic base plate Isolation voltage 3000 V∼ Planar glass passivated chips Low forward voltage drop Leads suitable for PC board soldering UL registered, E 148688 Applications Heat and temperature control for industrial furnaces and chemical processes Lighting control Motor control Power converter Advantages Easy to mount with two screws Space and weight savings Improved temperature and power cycling capability High power density Specification Semikron Part Number SKD 31/16 AC Line voltage 533V Device Configuration Single Phase Diode Rectifier Bridge DC Output @ 85 Deg C 4 Amp Package Size W:63mm L:32mm D:26mm Itsm 370 A VF(to) 0.85V Tj(max) 150°C rF 12mΩ Terminals Faston (6.3mm) Hole Centres Single M5 Gate Terminals N/A R th(j-c) 2°C/W R th(c-h) 0.3°C/W Weight 66g Isolation 3kV Factory Pack Qty 10 Certification UL Listed Semikron Headquarters Germany Datasheet Product Datasheet
$29.00
$34.22 inclGST -
XLG-240-H-AB, LED Driver/Power Supply with built in PFC, 240W, 100-305VAC input, 56VDC, 4.9Amp, Constant Current/Power/Voltage , Built In POT for Dimming with 0-10V PWM. IP67, Used as LED Driver
XLG-240-H-AB, LED Driver/Power Supply with built in PFC, 240W, 100-305VAC input, 56VDC, 4.9Amp, Constant Current/Power/Voltage , Built In POT for Dimming with 0-10V PWM. IP67, Used as LED Driver Wide Supply Voltage: 100-305VAC Output Voltage: 56V Output Current: 4.9A Power Rating: 240W Short Circuit, Overload, Overcurrent, Overvoltage Protected PFC Feature PF>0.93 (93% Efficiency) UL, CE, ROHS Approved Datasheet Product Datasheet
$97.00
$114.46 inclGST -
ProTec T1-750PV-S-P, ProTec Cartridge Replacement. MIDDLE PLUG In for T1-1500PV-3+0-S(-R)
ProTec T1-750PV-S-P, ProTec Cartridge Replacement. MIDDLE PLUG In for T1-1500PV-3+0-S(-R) Specifications Raycap part number ProTec T1-750PV-S-M-P Nominal Voltage 750VDC No of Poles 3 Category IEC / EN / VDE Type 1, Type 2/Open Type 1 SPD Listed Location of use String Box, Inverter Protection modes (+)-PE,(-)-PE,(+)-(-) PE Additional Remote Contacts YES Protective element MOV + GDT No Fault/Fault Indication Green Flag / Not Green Flag Surge discharge rating Per pole 12.5kA (10/350uS), 60kA(8/20uS) Internal protection and safety Thermal disconnector in each MOV Standards IEC/EN 61643-11 Datasheet Product Datasheet GDT/MOV/TVS Tester SPD Tester
$145.50
$171.69 inclGST