BH-100-1-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, +/-10V Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/-100 Amp DC, +/-10VDC Bipolar or 0-10V Bipolar Analogue Output
Features
⌀31mm Aperture
Split Core
DC Bipolar or Bipolar Measurement
+/-10V analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Mount
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-1-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 0-10VDC Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
BH-100-2-24, Split Core Hall Effect DC Current Transducer, +/-100 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
Compact and versatile Split Core DC current sensor, +/100 Amp DC, 4-20mA Bipolar Output
Features
⌀31mm Aperture
DC Bipolar Measurement
4-20mA analogue output
Busbar, or DIN Rail Mounting
Isolated plastic case recognised according to UL94-V0
Advantages
High isolation between primary and secondary circuits
Easy installation
DIN Rail Kit available
Applications
-Automation Systems
Analogue current reading for remote monitoring (e.g. Motor)
-Data Loggers
Self Powered. Will not drain data logger batteries
-Panel Meters
Simple connection displays power consumption
Specification
Fastron Part Number
BH-100-2-24
Technology
DC Hall Effect Current Transducer with Process Output
ROHS
Yes
Supply Voltage
24VDC
Nominal Current (DC)
+/-100 Amp
Response Time
< 200mS
Output
Bipolar 4-20mA Analogue
Isolation
2.5kV (AC, 50Hz, 1 min)
Bandwidth
DC
Mounting Style
DIN Rail Mount
Operating Temperature Range
-40°C / 85°C
Accuracy
1%
Termination Style
Elevator Screw
Unit Weight
120g
Factory Pack Qty
6
Datasheet
Product Datasheet
F19-271YF19-271Y-L, 19mm Pushbutton Switch Metal with YELLOW Ring Illumination, 1xNO 1xNC, 3 Amp (Nominal) 5 Amp (Max) @ 250VAC or 24VDC, 24VDC Illumination Supply, 0.05 Million Ops
Description
Pushbutton switch available in version Standard, Illuminated, with Point Illumination, 1xNO 1xNC, Lettering, varnished in different colours
Assembly by mounting with nut
Pin connections, Pins with Soldering Aid or Clip for Pins
Characteristics
Housing and actuator material types: zinc die-cast with nickel plating or stainless steel
Wide range of materials, colours, lettering, colours of illumination - Switching voltage max. 250VAC 30VDC, switching current max. 12 Amp
24VDC Illumination Supply Voltage
Zinc die-cast for housing and actuator For indoor use, no Illumination, 1xNO 1xNC, no lettering
Stainless Steel for actuator Optional point illumination and laser lettering with standard or customer-specific symbols
Stainless Steel for housing and actuator for use in harsh environments outdoors (see technical data)
Tamper Proof suitable for public spaces
Specification
Fastron Electronics Part Number
F19-271Y
Switch Size
20 x 19mm
Nominal Voltage
250VAC/DC
Rated Power
750W
Switch Type
Momentary1NO + 1NC
Illumination voltage
24VDC @ 10mA
Illumination type
YELLOW RING
Nominal Current (AC/DC)
3 Amp @240VAC/24VDC
Contact Resistance ON/OFF
<100m Ohm
Dimensions
ø22 x 14.6mm
Operating Temperature Range
-20°C / 85°C
Termination
Faston/Solder Pins
IP Protection Rating
(IP 67 with Oring) IP 64 (IP40 switching circuit)
Unit Weight
40g
Factory Pack Qty
10
Datasheet
Product Datasheet
Fastron FRTD-8-247-3-12-5000PVC, Class A 247 x 8mm Probe, 12 x 3mm Tip, 304 Stainless Steel w/ 5000mm PVC Tails, -50 to 100 Deg C
Class A Accuracy
Teflon/Screen/Teflon Cable
Low Long Term Drift
Rated for -50 to 200 Deg C Max
Spring Cable Connection
6 x 150mm
MIMS
Recommended to use BSP Fitting for mounting
Specification
Fastron Part Number
FRTD-8-247-3-12-5000PVC
Sensor Type
RTD Pt100 Thermocouple
No of Wires
3
Material
304 Stainless Steel
Shaft Length
247mm (12mm Tip)
Shaft Thickness
8mm (3mm Tip)
Approvals
CE, ANSI, ROHS
Accuracy
Class A
Cable length
5 Meter
Cable Type
Teflon/Screen/Teflon
Temperature Range
-50 to 200 Deg C
Special Feature
High Temperature Epoxy Sealed
Mounting Style
Loose (BSP Fitting recommended)
Weight
500g
Factory Pack Qty
1
Datasheet
Product Datasheet
Fastron Electronics SCT-F10-5, 5 Amp, 0.333v Class 1 Series Current Transformer, Equivalent to SCT-0400-10 (CE Approval, No UL approval)
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Fastron Part Number
SCT-F10-5
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 8 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
UL Approved Version
SCT-0400-05
Magnelab SCT-0400-005, 5 Amp, 0.333v Class 1 Series Current Transformer, 10mm Aperture, UL approved
Features
Quick Release Split Core System
Cable Mount
0.333v Output
Self Powered
Rated System Voltage 0.60/3kV
0.5M Flying Leads
Applications
US Based Metering Equipment
Energy Monitoring
AC Power Control Systems
Power Factor Correction
Power Quality Measurements
Specification
Magnelab Part Number
SCT-0400-005
Technology
Split Core AC Current Transformer
Ratio
5/0.333v
Aperture Size
ø 10 mm
VA Rating
N/A
Accuracy Class
Class 1
Output
0.333v (+20%)
Isolation
3kV (AC, 50Hz, 1 min)
Bandwidth
50-60Hz
Mounting Style
Cable Mount/Busbar Mount
Operating Temperature Range
-15°C / 45°C
Continuous Current (max)
5Amp x 1.2
Termination Style
0.5M Flying Leads
Unit Weight
100g
Factory Pack Qty
9
Datasheet
Product Datasheet
Application Notes
Installation Guide
H37 (Semikron P35) Heatsink Profile 40mm x 250mm, Various Lengths cut to order, Milled or Raw Finish
Note: for Milled finish. we can mill 150mm each pass leaving a line in the centre.
Note: for any lengths not showing in stock, and we have longer lengths in stock, the profile is available in 2-3 days to cut and mill.
Datasheet
Product Datasheet
GO 4-SMS/SP3, O/L Hall Effect Current Sensor with evaluation PCB, 4 Amp
Features
Hall effect measuring principle
Galvanic separation between primary and secondary circuit
Insulated test voltage 3000 V RMS
Low power consumption
Extremely low profile
Single power supply +5 V
Double overcurrent detection
Fixed offset & sensitivity
Response time 2 µs.
Advantages
Small size and space saving
High immunity to external interference
High insulation capability Industrial.
Low electrical resistance (0.75 m?)
No magnetic hysteresis
Robust against external fields and cross-talk.
Applications
Appliances
Small drives
HVAC
Solar
E-Bikes
Standards
IEC 62109-1: 2010
IEC 60950-1: 2005
IEC 61800-5-1: 2007
UL 1577: 2014.
Application Domains
Industrial
Specification
LEM Part Number
GO 4-SMS/SP3
Technology
Closed Loop Hall Effect
ROHS
Yes
Supply Voltage
3.3 VDC
Load Current (RMS + DC)
4 Amp
Overload Capability
+/-200 Amp
Output
2.5 Vref
Isolation
2.5 kV
Bandwidth
DC-300 kHz
Mounting Style
Surface Mount - SOIC 8 Pin
Operating Temperature Range
-40°C / 125°C
Accuracy
2%
Termination Style
N/A
Unit Weight
10g
Factory Pack Quantity
150
Datasheet
Product Datasheet
Fastron FC5-H-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 48x96mm, 0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-H-1U-2-G-4
Control Output
0-10V
Input
Multirange K,E,J,N,T,S,R,B Thermocouple, PT100/Cu20 RTD Input/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 48x96mm with SSR/Relay output)
Mounting Style
48x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-W-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x48mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-W-1U-2-G-4
Control Output
0-10V
Input
Multirange Type E,J,N,T,S,R,B, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 96x48mm with SSR/Relay output)
Mounting Style
96x48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol
Fastron FC5-L-1U-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Linear Current/Voltage and PT100/Cu20 RTD Input, 96x96mm,0-10V Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-L-1U-2-G-4
Control Output
0-10V
Input
Multirange Type K, J, E,S,T,R, Pt100, Cu50/Linear Current 4(0)-20mA/Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 96x96mm with SSR/Relay output)
Mounting Style
96x96mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet & User Manual
Datasheet
User Manual
FC5 Communication Protocol
Fastron FC5-S-R-2-G-4 PID Controller, 24VDC with 2 x Relay Alarms, K,E,J,N,T,S,R,B Thermocouple, Pt100 or Cu20, Optional Linear Current/Voltage, 48x48mm,Relay Output
4-digit displays (0.5s response)
Drip-proof / Dust-proof IP66 (front panel only)
Input signals can be converted to insulated -0-10V, Relay, 12VDC (SSR) and 4 to 20 mA DC outputs available
Each unit needs just 75 mm depth panel space
Specification
Fastron Part Number
FC5-S-R-2-T/R-2
Control Output
Relay 3A(Resistive), 1A(Inductive load cos Ѳ=0.4)
Input
Multirange Type,K,E,J,N,T,S,R,B, Pt100, Cu50/(Optional)Linear Current 4(0)-20mA/(Optional)Linear Voltage 0-10(5)V
Option 1
2 x Relay Alarms standard (Excludes 48x48mm with SSR/Relay output)
Mounting Style
48 x 48mm Panel Mount
Supply Voltage
100 - 240VAC +/-10%
Termination Style
Screw
Sampling Time
100ms
Weight
150-270g
Factory Pack Qty
10
Datasheet
Datasheet
User Manual
Modbus Protocol
FC5 Communication Protocol