Search results for "선불유심20만원 Gora43430aa 휴대폰미납소액대출 고라통신 선불유심 현금화 정식업체 저신용자비상금소액대출 청송군 24시 당일소액급전대출"
-
16.915.220, Regulator for AAN5333 Alternator MAHLE - Letrika(Iskra) Alternator, 14VDC 150Amp
Heavy Item - No Free ShippingISKRA LETRIKA 16.915.220, Regulator for AAN5333 Alternator MAHLE - Letrika(Iskra) Alternator, 14VDC 150Amp OEM MAHLE(Letrika) 16915220 Letrika AAN5333 Specification ISKRA (MAHLE) Part Number 16.915220 ISKRA/LETRIKA/MAHLE 16915220
-
KNL630-00-24VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 630 Amps, 24VAC Coil
Heavy Item - No free ShippingIskra Doo KNL630-00-240VAC, AC Contactor 240/400/500/690V, 3 Pole 3 x NO, Nominal Current = 630 Amps, 240VAC Coil Capacitor duty contactors are designed to meet the requirements of capacitor duty applications. Contactors are fitted with a block of three auxiliary contacts connected in series with six quick discharge damping resistors, two per each phase. Peak current is limited to the value within the contactor making capacity. Features : High contact reliability at low voltages High electrical and mechanical endurance and high switching capacity Four and Three-pole contactors Optional auxiliary contacts Ratings from 6 Amp to 1000 Amp UL, CSA Approved Advantages : Saves costs of expensive replacement Long electrical life Reduces watt losses during “ON” condition, saves energy High safety No risk of dangerous voltage Less maintenance and downtime Standard control voltages: 24 V 50/60 Hz, 240 V 50/60 Hz, 415 V 50/60 Hz Specification Iskra Doo Part Number KNL630-00-24VAC Functions 3 Pole Contactor (3 x NO) Nominal Voltage 230/400/500/690VAC @ 50/60Hz Current Carrying Capacity as per UL 630 Amp Continuous @ 55 Deg C Auxiliary Contacts Optional G350 Snap On (2NO + 1NC or 1NO + 2NC) Trip Delay Time 2-10ms Electrical Life 700,000 Ops Operating Temperature -25 to 55 Deg C Mechanical Operations 10.000,000 Ops Control Voltage 24VDC Power Dissipation 90W per pole Approvals UL, CSA Standards IEC/EN 60947-4-1, AS/NZ 61009-1 Weight 17kg Enclosure Material UL94 Factory Pack Qty 1 Datasheet Product Datasheet Contactor Catalogue Iskra Contactor Catalogue
-
KLV3221, 250 Kvar, 6.58uF, 50Hz, 11kV, Single Phase Power Factor Correction Capacitor
Heavy Item - No Free ShippingKLV3221, 250 Kvar, 6.58uF, 50Hz, 11kV, 200 Kvar, 5.26uF, 50Hz, 11kV, Single Phase Power Factor Correction Capacitor Characteristics and utility 250 kVar @ 11kV @ 50 Hz 50kvar Heavy Duty 100,000Hours Singel Phase Capacitor with two bushings Reactive power factor correction Oil Type Connector type - single sided terminal Indoor mounting Safety Protection by internal fuses Self Healing Construction and materials Low losses metallized self-healing polypropylene film, high density, high temperature and greater dielectric resistance Volt/µ UL 94 V0 Resin Side & Top mounting brackets Standards IEC 60831-1/2 EN 60831-1/2 Specification Iskra Part Number KLV3221, 200 Kvar, 5.26uF, 50Hz, 11kV Technology Oil Type, Low Loss, Self Healing Dimensions 427 x 145 x 835mm Standards IEC 60831-1/2, EN 60831-1/2 Voltage 11kV @ 50Hz Max Continuous Overvoltage 1.1 x In Kvar 250 Kvar Capacitance 6.58uF Insulation level 38/95kV Indoor/Outdoor Version Outdoor Tolerance On Capacitance -5% + 10% (others on request) Current (In) 22.7 Amp No. Of Bushings 2 Mounting Clamps Side & Bottom Overpressure Disconnection System NO Self Extinguishing Resin YES Internal Fuses YES Self Healing YES Operating Temperature Range 50°C Max, 30°C Mean(1 year), 40°C Mean(24 hrs) Lifetime 100,000 Hours TerminalStyle Clamp Terminals Unit Weight 46kg Factory Pack Quantity 1 Datasheet Product Datasheet
-
GV141BAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67
Free Aus Post Shipping for $300 spendGigavac GV141BAB, Contactor SPST-NO, 400+ AMP, 12-100VDC, 12VDC Coil, 38cm Flying leads, SPST-NO Auxiliary Contact, IP67 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Giagavac Part Number GV141BAB Main Contact Type SPST-NO Auxiliary Contact Type SPST-NO Coil Voltage 12VDC Load Current 400+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature Internal Coil Supression Mounting Style Panel Mount (M5) Load Voltage Range 12 - 100VDC Standards CE, UL1604, IP67, SAEJ1171 Termination Style M8 Unit Weight 450g Factory Pack Qty 1 Datasheet Product Datasheet
-
G64C741, HV Relay, 50kVDC, 10A, SPDT Form C, 24VDC Coil, 1,000,000 Cycles, 55kV Isolation, 12" Flying Leads
Free Aus Post Shipping for $300 SpendGigavac G64C741, HV Relay, 50kVDC, 10A, SPDT Form C, 24VDC Coil, 1,000,000 Cycles, 55kV Isolation, 12" Flying Leads Features Hermetically Sealed (Patented) rated to 85 Deg C High Efficiency Form C DC Coil Gas filled Small and lightweight Flexible package for installation Specification Gigavac Part Number G64C741 Main Contact Type SPDT-Form C Auxiliary Contact Type N/A Coil Voltage 24VDC Load Current 10 Amp Mechanical Life @ 0 Amp 1,000,000 Operations Nominal Load Voltage 50kV rms Control Input Terminals 12" Flying Leads Special Feature N/A Mounting Style Panel Mount (M4) Peak Voltage 55kVDC Standards UL508, NEC 690.11 and 690.12 DC Termination Style Screw Unit Weight 335g Factory Pack Qty 1 Datasheet Product Datasheet
-
DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply
Free Aus Post Shipping for $300 SpendLEM DK 200 B420 B, Split Core Hall Effect DC Current Transducer, 100, 150, 200A DC, 4-20mA bipolar output, 20-50VDC supply Compact and versatile Split Core DC current sensor, selectable 100, 150, 200 Amp DC. Choice of output types: 4-20 mA, 0-5 V or 0-10 V Features Split Core DC Bipolar Measurement 4-20mA analogue output Busbar or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages Large aperture for busbar/cable up to 21.7mm sqr High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification LEM Part Number DK 200 B420 B Technology DC Current Transformer with Process Output ROHS Yes Supply Voltage 20-20VDC Nominal Current (RMS + DC) 100,150,200 Amp Selectable Response Time < 100ms Output 4-20mA Bipolar Analogue Isolation 3kV (AC, 50Hz, 1 min) Bandwidth DC Mounting Style Panel Mount Operating Temperature Range -40°C / 85°C Accuracy 2% Termination Style 2 x UNC8 Cylindric Head Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet Application Notes LEM Applications Manual 3rd Edition
-
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-050-010-24, Hall Effect DC Current Transducer, +/-50 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-50 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-50A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-050-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-50 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture
FTA-300-010-24, Hall Effect DC Current Transducer, +/-300 Amp , +/-10VDC Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-300 Amp , +/-10VDC Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement +/-10VDC Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-300A ~+/-100A AC) Busbar, or panel mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-300-010-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-300 Amp Response Time < 10uS Output Bipolar +/-10VDC Analogue Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
ART-B22-D125-SP6 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter, 6M integrator Cable
Free Aus Post Shipping for $300 SpendLEM ART-B22-D125-SP6 + AI-P1A - 3 Pcs, 3 Phase Rogowski Coil Set, Class 1, 1 Amp AC, Sensitivity, and Measurement Range, 12.5cm Diameter, 6M integrator Cable The universal Rogowski coil integrator AI-P1A complements LEM’s flexible clip-around coil ART and ARU range. The design is based on digital processing to give combined dynamic range, accuracy and versatility of use. It offers a wide range of output signals both RMS and instantaneous. AI-P1A is DIN rail mounted and can be stacked for multiphase application without spacing thanks to its low power dissipation. Input signal Accuracy Class 1 (IEC 61869-2) [1]. Linearity error ≤ 0.10 %. Protection degree IP2X. 35 mm DIN rail mounted. Push-in terminals. 1 Amp instantaneous output. 6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz. 12 selectable ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A. Ambient operating temperature −25...+70 °C. Advantages Compact design for DIN rail assembly High accuracy Class 1 (IEC 61869-2) Setup by user via Select / Edit buttons Clear status indication via bi-color led Applications MV/LV substations on LV side: Transformer Condition Monitoring Power metering: current measurement for active power calculation Building sub-metering: energy efficiency monitoring, consumption analysis and cost allocation Power quality monitoring: electrical loads and distribution system equipment Fault Detection, Isolation and Repair (FDIR): isolate the site of the fault Remote Terminal Units (RTU) Phasor Measurement Units (PMU) Standards IEC 61010-1: 2010 UL EMC: IEC 61326-1:2012 Options Cross Power Plug-in: side contacts to stack up to 3 Integrator modules and use only one power supply. Specification LEM Part Number ART-B22-D125-SP6 + AI-P1A - 3 Pcs Function 3 Phase AC Current Measurement Measuring Range Selectable 5000,4000,2000,1500,1000,800,600,500,400,300,200,100Amp Sensitivity Selectable 22.5,70,80,85,100,120mV/kA @ 50 Hz Output 1 Amp Instantaneous Frequency Measuring Range 50-1500Hz (15th Harmonic) Operating Voltage 10-32VDC Accuracy 1% from 25 to 5000 Amp Current Consumption 100mA (max) Dimensions 100mm x 78mm x 15mm (Integrator), 12.5cm Diameter (Coils) Mounting Din Rail Mount Integrator to Coil cable 6M Twisted and Screened Integrator to Meter cable User Supplied Shielded cable 1.5mm sqr, up to 6m long Operating Temperature -25°C - 70°C Storage Temperature -45°C to 80°C Isolation (50Hz, 1 min) 1.5kV True RMS Response Time 160-190ms Termination Style Push-in for 1.5mm sqr wire Weight 58g Factory Pack Qty 1 Certifications UL, ROHS Datasheet AI-P1A Datasheet ART Series Datasheet Application Notes User Notice 1) The Rogowski coil can measure any primary current as there is no saturation effect. 2) Not tested given that in the worst case (load = 0 Ohm i.e. short circuit on the output) the peak dissipated power remains low (< 2 Watts) 3) Frequency bandwidth and phase shift modelling schematic can be provided on request. 4) Referring to the main phase offset of 90 ° (a Rogowski coil is a derivative current transducer) 5) Considering a primary conductor of at least ⌀ 15 mm, perpendicular and in contact with the Rogowski coil. 6) Considering an external conductor of at least ⌀ 15 mm the same current level than internal conductor, perpendicular and in contact with the Rogowski coil.
-
RS1API420MA280080R, Solid State Relay Based Integrated Proportional Controller, 4-20mA Input, 240VAC 80Amp Load
Free Aus Post Shipping for $300 SpendRelequick RS1API420MA280080R Proportional Phase Control Solid State Relays 4-20mA, or 2-10V Proportional Phase Control Input Ratings from 25A to 100 Amp @ 70-280 VAC SCR output for heavy industrial loads Instantaneous turn-on outputs UL/CE/ROHS Compliant Includes Plastic IP20 Terminal Cover Direct bond copper substrate Direct power lead frame Epoxy free design Specification Relequick Part Number RS1API420MA280080R Switching Type Phase Angle (Random Crossing) ROHS/CE/UL Yes Control Voltage 4 - 20mA Load Current 80 Amp (rms) Surge Capability 910 Amp (peak) Special Feature Proportional Controller + SSR Mounting Style Panel Mount Load Voltage Range 70-280VAC Max Non Repetitive Peak Voltage 850 Vp Termination Style Screw Unit Weight 160g Factory Pack Qty 20 Datasheet Product Datasheet Product Notifications Equivalent Parts Crydom MCPC2450 MCPC2490 or Contact Us for Possible Replacement
-
84871034, Current Monitoring Relay with Hysteresis and T2 time Single Phase 0.1 - 10 Amp EIH Series, 100-240VAC/24VDC Supply, Obsolete, Replaced by 84871130
Free Aus Post Shipping for $300 SpendCrouzet Automation 84871034, Current Monitoring Relay with Hysteresis and T2 time Single Phase 0.1 - 10 Amp EIH Series, 100-240VAC/24VDC Supply, Obsolete, Replaced by 84871130 For Current Monitoring of AC Current from 1 Amp to 20 Amp. Features: 0.1 to 10 Amp Trip Range 0.1 to 10 Second Trip Delay 0 to 100% Hysteresis T2 Hysteresis Delay Time True RMS measurement Specification Crouzet Part Number 84871034 (Single Phase C-Lynx Current Monitoring Relay With SPDT Contacts) Function Current Threshold Montoring Nominal Current 0.1- 10 Amp AC Digital Outputs 1 x C/O Relays, 250VAC/DC @ 8 Amp Min Breaking Current 10mA/5VDC Delay on Threshhold Crossing 0.1 → 3s (0, +10%) Delay on Pickup 600ms Alarm Delay on Time (max) 200ms Reset Time 1500ms Adjustable Hysteresis 5 - 50% of Threshhold Maximum Measurement Cycle Time 30ms/True RMS Measurement Measurement Accuracy 1% Supply Voltage Range 24VAC/DC 48VAC 120/220VAC +/-15% Termination Style Screw Weight 170g Certification CE, UL, CSA, GL, ROHS Factory Pack Qty 1 Over Voltage Category 3 in accordance with IEC/EN 60664-1 Pollution Degree 2 in accordance with IEC/EN 61131-2 Protection rating IP40 (Front), IP20 (Rear) Mechanical Resistance Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Resistance to HF Interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Conducted and radiated emissions Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Operating Temperature -20 →+70 °C except CB and XB versions in VDC : -30 →+70 °C (+40 °C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 Datasheet Product Datasheet
-
GV211CAX, Contactor SPST-NO, 150+ AMP, 12-900VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69
Free Aus Post Shipping for $300 spendGigavac Sensata GV211CAX, Contactor SPST-NO, 150+ AMP, 12-900VDC, 24VDC Coil, 38cm Flying leads, IP67, IP69 Features Hermetically Sealed UL1604 for Class I & II Div 2 and Class III for use in hazardous locations IP67 - Temporary water immersion (30 Min) SAE J1171 External ignition protection ISO8846 Protection against ignition around flammable gasses CE Approved High Efficiency Dual DC Coils - Very low 12,24,48VDC continuous coil power with no EMI emissions or cross-talk on your system control power Ideal for battery powered systems or where low power is needed PWM option provides additional drive control flexibility Built in Coils suppression for all DC Coils Flexible package for installation Specification Gigavac Part Number GV211CAX Main Contact Type SPST-NO Auxiliary Contact Type None Coil Voltage 24VDC Load Current 150+ Amp Mechanical Life @ 0 Amp 1,000,000 Operations Dielectric at Sea Level (leakage <1mA) 2.5kV rms Control Input Terminals 38cm Flying Leads Special Feature N/A Mounting Style Panel Mount (M5) Load Voltage Range 12 - 900VDC Standards CE, UL1604, IP67, SAEJ1171, UL508 Termination Style M8 Unit Weight 250g Factory Pack Qty 1 Datasheet Product Datasheet