Search results for "텔레@UPCOIN24*$코인믹싱코인전송대행"
-
DTC1-A/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 4-20mA output
Free Aus Post Shipping for $300 spendFastron DTC1-A/M-C5, DIN Rail Mount Temperature/Humidity Controller, Multirange Input, 85-265VAC, 4-20mA output Optional converter function 2 Input 1 Output, and 1 Input Two Output Versions available Optional 60 Segment Multi Pattern Program Control feature 4-digit display. Suit most industries including Temperature, Humidity, Pressure (0.5s response) CE Approved Each unit needs just 22.5mm width Din Rail space EC Compliant (Details) Various specials available for unique applications. Specification Fastron Part Number DTC1-A/M-C5 Control Output 4-20mA Input Multirange K/J/R/S/B/E/T/Linear Voltage Current(Optional)/N/W1/W2/Pt100 Alarm Relay 3A(Resistive), 1A(Inductive load cos ??=0.4), 240VAC/30VDC Options RS485 Comms Mounting Style 22.5 x 75mm Din Rail Mount Supply Voltage 85 - 265VAC Termination Style Screw Weight 230g Factory Pack Qty 1 CE Yes ?? Selection Chart PWM Control Wiring Datasheet DTC1 Brochure DTC1User Manual DTC1 User Manual Comms versions Alarm Table DTC1 (Program Control Version) User Manual
-
FTA-020-420B-24, DC Current Transducer, +/-20 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-020-420B-24, DC Current Transducer, +/-20 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-20 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-020-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-20 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-010-420B-24, DC Current Transducer, +/-10 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-10 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-10mA ~+/-10A AC) 10uS Response (0-+/-10A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-010-420B-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-10 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
Rish Xmer 104-80 (45) 1500/5 Class 0.5, 20VA, ⌀ 65mm or 85 x 12mm Busbar
Heavy Item - No Free ShippingRishabh Rish Xmer 104-80 (45) 1500/5 Class 0.5 Series Current Transformer Features Built In Sealable Terminal Covers Mounting Feet Supplied Self Powered Rated System Voltage 0.72/3kV IEC185, BS 7626, BSEN 60044-1 and IEC 60044-1 Applications Metering Equipment Energy Monitoring AC Power Control Systems Power Factor Correction Power Quality Measurements Specification Rishabh Part Number Rish Xmer 104-80 (45) 1500/5 Class 0.5 Technology AC Current Transformer Ratio 1500/5 Aperture Size ⌀ 65mm or 85 x 12mm Busbar VA Rating 20VA Accuracy Class Class 0.5 Output 5 Amp AC (+20%) Isolation 3kV (AC, 50Hz, 1 min) Bandwidth 50-60Hz Mounting Style Panel Mount/Busbar Mount Operating Temperature Range -30°C / 85°C Continuous Current (max) 1500Amp x 1.2 Termination Style Screw Unit Weight 0.9kg Factory Pack Qty 9 Datasheet Product Datasheet
-
FTA-020-420-24, DC Current Transducer, 0-20 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-020-420-24, DC Current Transducer, 0-20 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-20 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-20mA ~0-20A AC) 10uS Response (0-0-20A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-020-420-24 Technology DC Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-20 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply
BH-15-2-24, Split Core Hall Effect DC Current Transducer, +/-15 Amp DC, 4-20mA Bipolar output, 31mm aperture, 24VDC supply Compact and versatile Split Core DC current sensor, +/-25 Amp DC, 4-20mA Bipolar Output Features ⌀31mm Aperture Split Core DC Bipolar Measurement 4-20mA analogue output Busbar, or DIN Rail Mounting Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Mount Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number BH-25-2-24 Technology DC Hall Effect Current Transducer with Process Output ROHS Yes Supply Voltage 24VDC Nominal Current (DC) +/-25 Amp DC Response Time < 200mS Output Bipolar 4-20mA Analogue Isolation 2.5kV (AC, 25Hz, 1 min) Bandwidth DC Mounting Style DIN Rail Mount Operating Temperature Range -40°C / 85°C Accuracy 1% Termination Style Elevator Screw Unit Weight 120g Factory Pack Qty 6 Datasheet Product Datasheet
$425.00
$501.50 inclGST -
Thyro-A-1A-230-170-H3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_170 Amp
Thyro-A-1A-230-170-H3, Thyro-A-1A-Series Single Phase SCR Controller 170Amp 230VAC +10%/-57%, Voltage Control, Phase(VAR), Burst(TAKT), Quick TAKT(QTM), VT(on Request), SWITCH Operating Modes, Rating_170 Amp Features Optional Profinet, Profibus, Ethernet, Modbus Comms 230VAC +10%/-57%, Voltage Control, +10/-57% Voltage, Current or Power Control Built in Fuse Smallest footprint on the market Single Phase Phase Angle & Burst Controller with SWITCH operation mode SWITCH between Phase(VAR) or Burst(TAKT) control modes Quick TAKT Mode (QTM), VT Mode (on request) (0)4-20mA, 0(1)-5V, 0(2)-10V or POT input Proportional Control Removable Cover Potentiometer Adjustment USB Configuration/Bias Setting Synchronisation Function (dASM Module Recommended) Applications Electrical Ovens, Kilns, or Furnaces Primary Control of Transformer Loads in Phase or Burst Fire mode AC Soft Starter (Combined with PLC) Power Regulation Applications Electric Boilers Brewery Heating Industrial Light Dimming Suitable for extreme environments such as mining Series Optional Features For HRL Current Control/Feedback Programmable Relay Alarm Output Load Monitoring Analogue Output For HRLP As above with Power Control Feedback Communication Options Standard Thyro Bus Module BasicBus Module Specification Advanced Energy Part Number Thyro-A-1A-230-170-H3 Approvals CE, UL508A, EU Directive 2014/35/EU & 2004/108/EC Control Accuracy 3% at rated voltage Rated Operating Temperature 45°C Temperature Derating 0.9 x Inom @ 50 Deg C, 1.1 x Inom @ 35 Deg C SCR Configuration Single Phase AC Switch Control Modes Phase(VAR), Burst(TAKT), QUick TAKT(QTM), Hybrid(VT on request) Control Input 4(0)-20mA, 0(1)-5V, 0(2)-10V, POT Load Current 16 to 1230 Amp @ 45 Deg C (110% @ 35 Deg C Max) Control Range 0-100% Options Conformal Coating for Gas or High Humidity Environments Mounting Style Panel Mount Supply Voltage Range 230VAC +10%/-57%, Voltage Control, +10/-15% (-57% with 24VDC Aux Supply) Soft Start Via PLC input Termination Style Screw Unit Weight 2.1 to 30kg Factory Pack Qty 1 Technical Docs Brochure User Manual Thyro A Series Quick Installation Guide Setting Up Comms on Thyro A Series Controllers Anybus Device Ethernet IP Setup Guide
$2,042.70
$2,410.39 inclGST -
FTA-030-420B-24, Hall Effect DC Current Transducer, +/-30 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture
FTA-030-420B-24, Hall Effect DC Current Transducer, +/-30 Amp , 4-20mA Bipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, +/-30 Amp , 4-20mA Bipolar Output Features ⌀21mm Aperture DC Bipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- +/-20mA ~+/-20A AC) 10uS Response (0-+/-20A ~+/-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-030-420B-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) +/-30 Amp Response Time < 120mS Output Bipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FPC1-40-40C-24VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 40 Amp 50/60Hz, 24VAC/DC Coil Voltage, Hum Free
Fastron FPC1-40-40C-24VAC/DC, 4 Pole 4 x SPST NO, Modular Contactor 440VAC 40 Amp 50/60Hz, 24VAC/DC Coil Voltage, Hum Free Features 40 Amp (rms) @ 440VAC DIN Rail Mount Slim package CE Compliant to IEC 60664 IP20 Specification Fastron Part Number FPC1-40-40C-24VAC/DC Switching Type 4 x SPST NO Approvals CE Coil Voltage 24VAC/DC Load Current (RMS/DC) 40 Amp (rms) @ 440VAC Special Feature Hum Free Mounting Style DIN Rail Mount Load Voltage Range 440VAC 50/60Hz Isolation 4kV Termination Style Screw Unit Weight 295g Factory Pack Qty 20 Datasheet Datasheet Auxiliary Contacts Selection Guide
$55.00
$64.90 inclGST -
ATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply
Free Aus Post Shipping for $300 SpendATO-CUS-DC20000-4000-420U, O/L Hall Effect Current Transducer, 0-4000A, 4-20mA Instant Output, +24VDC Supply For the electronic measurement of currents: DC, AC, pulsed, mixed, with a galvanic isolation between the primary circuit (high power) and the secondary circuit (electronic circuit). Features Insant output versions 4-20mA, 0-20mA, 0-10V, 0-5V output Hall effect measuring principle Galvanic isolation between primary and secondary circuit Instantaneous voltage output Isolation voltage 2.5kV Rms /50 Hz /1min Low power consumption Package in ABS Instantaneous voltage or current output options Advantages Easy installation Small size and space savings Only one design for wide Ratings range High immunity against external interference Applications Battery supplied applications Uninterruptible Power Supplies (UPS) Power supplies for welding and telecom applications Application domain Industrial Traction Specification LEM Part Number ATO-CUS-DC20000-4000-420U Technology Open Loop Hall Effect ROHS Yes Supply Voltage +24VDC Load Current (RMS + DC) 4000 Amp Overload Rating N/A Output 4-20 mA Instantaneous Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Only Mounting Style Busbar or Panel Mount Operating Temperature Range -25°C / 85°C Accuracy 1% Termination Style F2023A (FUJICON) Unit Weight 6kg Factory Pack Qty 2 Datasheet Product Datasheet
-
FTA-045-420-24, Hall Effect DC Current Transducer, 0-45 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-045-420-24, Hall Effect DC Current Transducer, 0-45 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-20 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-20mA ~0-20A AC) 10uS Response (0-0-20A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-015-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-45 Amp Response Time < 120mS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST -
FTA-200-420-24, Hall Effect DC Current Transducer, 0-200 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture
FTA-200-420-24, Hall Effect DC Current Transducer, 0-200 Amp , 4-20mA Unipolar Output, 24VDC supply, 21mm Aperture Compact and versatile Split Core DC current sensor, 0-200 Amp , 4-20mA Unipolar Output Features ⌀21mm Aperture DC Unipolar Measurement 4-20mA Instantaneous output 120mS Response (for 0- 0-10mA ~0-10A AC) 10uS Response (0-0-200A ~0-100A AC) Panel mount Isolated plastic case recognised according to UL94-V0 Advantages High isolation between primary and secondary circuits Easy installation DIN Rail Kit available Applications -Automation Systems Analogue current reading for remote monitoring (e.g. Motor) -Data Loggers Self Powered. Will not drain data logger batteries -Panel Meters Simple connection displays power consumption Specification Fastron Part Number FTA-200-420-24 Technology DC Hall Effect Current Transducer with Instant Output Yes Supply Voltage 24VDC Nominal Current (RMS + DC) 0-200 Amp Response Time < 10uS Output Unipolar 4-20mA Instant Isolation 2.5kV (AC, 50Hz, 1 min) Bandwidth DC Aperture 20mm Mounting Style Panel Mount Operating Temperature Range -10°C / 85°C Accuracy 1% Termination Style 4 Pin Plug (Included) Unit Weight 300g Factory Pack Qty 6 Datasheet Product Datasheet
$285.00
$336.30 inclGST